V5 Ultimate
Ultimate
PricingResourcesCompany
English (original)العربيةDeutschΕλληνικάEspañolFrançaisItalianoעברית日本語한국어NederlandsPolskiPortuguêsSvenska
Talk to us Log in Start free trial
Food & Beverage
  • Bakery & Confectionery
  • Food Processing
  • Ingredients & Dry Mixes
  • Sausage & Meat Products
  • Produce Packing
  • Pet Food & Pet Supplements
  • Dairy & Chilled Foods
  • Beverages & Liquid Manufacturing
  • Infant Formula
Pharma & Life Sciences
  • Radiopharmaceuticals
  • Pharmaceutical
  • Medical Devices
  • Veterinary Pharmaceuticals
  • Blood & Tissue
  • Diagnostics & IVD Kits
  • Reference Materials & Standards
  • OTC Topical Creams & Gels
Supplements & Personal Care
  • Dietary Supplements
  • Cosmetics & Personal Care
  • Cannabis & Hemp Manufacturing
  • Fragrances & Perfumery
  • Soaps & Personal Hygiene
  • Botanical Extracts & Essential Oils
Chemicals & Materials
  • Plastics & Resins
  • Agricultural Chemicals
  • Specialty & Industrial Chemicals
  • Printing Inks, Pigments & Construction Chemicals
  • Lubricants & Metalworking Fluids
  • Coatings, Adhesives & Sealants
Other Manufacturing
  • Consumer Products
  • Electronics & Electrical Assembly
  • Textiles & Nonwoven
  • Contract Manufacturing & Co-Packing
  • Packaging & Food-Contact Materials
  • Regulated Warehousing & Distribution
Explore all industries
  • Warehouse & TraceabilityReceive, store, pick and trace
  • Production & PlanningPlan jobs and guide production
  • Quality & LaboratoryTest, investigate and review
  • Documents & TrainingControl procedures and qualifications
  • Equipment & PerformanceMaintain assets and measure losses
  • Orders & IntegrationsConnect customers, suppliers and systems
  • Outputs & InsightsReports, KPIs and label design
Why V5? Product & Features
Why V5?Product & Features
  • Warehouse & TraceabilityReceive, store, pick and trace
  • Production & PlanningPlan jobs and guide production
  • Quality & LaboratoryTest, investigate and review
  • Documents & TrainingControl procedures and qualifications
  • Equipment & PerformanceMaintain assets and measure losses
  • Orders & IntegrationsConnect customers, suppliers and systems
  • Outputs & InsightsReports, KPIs and label design
Explore all industries
    • Bakery & Confectionery
    • Food Processing
    • Ingredients & Dry Mixes
    • Sausage & Meat Products
    • Produce Packing
    • Pet Food & Pet Supplements
    • Dairy & Chilled Foods
    • Beverages & Liquid Manufacturing
    • Infant Formula
    • Radiopharmaceuticals
    • Pharmaceutical
    • Medical Devices
    • Veterinary Pharmaceuticals
    • Blood & Tissue
    • Diagnostics & IVD Kits
    • Reference Materials & Standards
    • OTC Topical Creams & Gels
    • Dietary Supplements
    • Cosmetics & Personal Care
    • Cannabis & Hemp Manufacturing
    • Fragrances & Perfumery
    • Soaps & Personal Hygiene
    • Botanical Extracts & Essential Oils
    • Plastics & Resins
    • Agricultural Chemicals
    • Specialty & Industrial Chemicals
    • Printing Inks, Pigments & Construction Chemicals
    • Lubricants & Metalworking Fluids
    • Coatings, Adhesives & Sealants
    • Consumer Products
    • Electronics & Electrical Assembly
    • Textiles & Nonwoven
    • Contract Manufacturing & Co-Packing
    • Packaging & Food-Contact Materials
    • Regulated Warehousing & Distribution
PricingResourcesCompany
Start free trial Log in Talk to us
HomeGlossaryDevice Listing Number
Records · The complete guide

Device Listing Number

In short

Assess the provenance, establishment activities and proprietary names behind a listing reference before relating it to a controlled device configuration.

4,498 words · ~21 min read
A woman holds two white cartons while a man points to a printed comparison table beside a laptop directory and a tablet of export records.
On this page
  1. 01What a Device Listing Number establishes
  2. 02Separate the public view from private listing evidence
  3. 03Apply the US establishment scope before assessing records
  4. 04Establish who supplied the exports and when
  5. 05Join the export tables without losing their context
  6. 06Read establishment activities and names together
  7. 07Relate the records to the controlled configuration
  8. 08Worked cases: DL-F17 revision D
  9. 09Preserve exceptions through import and correction
  10. 10Close the review with a bounded decision
On this page · 10 sections
  1. 1What a Device Listing Number establishes
  2. 2Separate the public view from private listing evidence
  3. 3Apply the US establishment scope before assessing records
  4. 4Establish who supplied the exports and when
  5. 5Join the export tables without losing their context
  6. 6Read establishment activities and names together
  7. 7Relate the records to the controlled configuration
  8. 8Worked cases: DL-F17 revision D
  9. 9Preserve exceptions through import and correction
  10. 10Close the review with a bounded decision
AI · Explain it for MY operation

How does Device Listing Number apply to your shop floor?

Pick your industry and scale — Ask V5 rewrites the definition in your context, gives a worked example, and shows what V5 does on day one.

Your scale

01What a Device Listing Number establishes

Device Listing Number is the identifier used to reference a medical-device listing record in FDA's Device Registration and Listing Module. FDA device listing number is an alias for the same term.

For QA record review, treat the number as a record reference, not standalone evidence of quality release, clearance, approval, UDI-DI assignment or device-specific revision coverage. The immediate question is whether private listing evidence can support an owner assessment of the establishment activity, proprietary name and configuration under review.

Record or identifierReview questionEvidence boundary
Device Listing NumberWhich listing record is referenced?Connects records; does not establish configuration coverage.
Establishment registration numberWhich establishment is involved?Establishment identity alone does not resolve the activity reviewed.
Proprietary nameWhich marketed name appears?A matching name does not establish revision equivalence.
Internal configuration revisionWhich controlled design or packaging state is assessed?Needs an owner-supported relationship to the listing evidence.

Keep provenance, record date and unresolved differences attached to that assessment. A familiar number or matching name is a starting point for review, not a substitute for its reasoning.

See FDA Product Code for the broader identifier-register comparison and later portfolio assessment. This article addresses the earlier decision: whether the private listing evidence is suitable for that owner assessment.

02Separate the public view from private listing evidence

For US medical-device records, FDA’s DRLM download guidance says listing numbers are not publicly available. Treat the public registration/listing view as an observation of what the search displays, not as a source from which to obtain or reconstruct the private listing number.

For US medical-device listing information, FDA’s download guidance, introductory paragraph identifies the owner/operator contact person or official correspondent of a registered establishment as the recipient to whom listing numbers can be released. For that same US medical-device information, the guidance’s sharing provision describes those contacts choosing to download and share listing information with Custom House Brokers or other parties.

A practical QA comparison keeps the following evidence types separate. These are proposed review controls, not additional FDA requirements.

Evidence typeWhat to recordBoundary of the finding
Public observationEstablishment identity, information actually displayed, search terms and capture time.Describes the captured search result; does not supply the private listing key.
Exported rowThe original row and its association with the authorized sender and dated export.Describes the export’s contents; keep its origin distinguishable from the public capture.
Owner interpretationThe owner’s explanation of how the records relate to the device under review.An assessment to evaluate, not another database field.

Obtain the private listing key through the authorized export chain. Do not fill a missing key by matching a public establishment name or device description. Keep the public capture alongside the private records so a later reviewer can distinguish what was displayed from what the owner explained.

A proprietary name missing from a public search is a review question, not by itself a contradiction of a private name row. Record the difference neutrally and ask the owner to explain it before drawing a conclusion about coverage. Generic identifier distinctions belong in FDA Product Code; this comparison asks whether each observation has a traceable source and whether the apparent difference needs resolution.

03Apply the US establishment scope before assessing records

Start with the establishment’s actual operations, not its supplier-category label. As proposed review practice, identify the activities relevant to the US medical-device record review and check applicable exemptions under current Part 807 before reaching a registration or listing conclusion. Record the applicability assessment separately from the export comparison. This is an establishment-specific assessment, not a rule for every manufacturer or regulated product.

For applicable US medical-device establishment owners or operators, 21 CFR 807.22(b), registration and listing updates requires review and update of all establishment registration and device listing information on file at FDA. Keep that legal obligation distinct from the reviewer’s method for deciding whether a particular export supports the assessment.

Keep three layers explicit in the review record: binding regulation for legal obligations; FDA procedural guidance for procedural explanations; and proposed QA review practice for local evidence controls. Provenance checks, freshness decisions, file controls and configuration assessments belong in that last category here. Describe their acceptance criteria as local review criteria, rather than FDA-mandated fields or formats.

For US medical-device representations about establishment registration, check the current text of 21 CFR 807.39 for scope. Treat that representations question separately from the operational evidence boundary covered above.

Use Device Classification and the Part 807 guide for broader regulatory context. Keep this review focused on the establishment activities and proprietary names shown by the records. Escalate unresolved applicability questions to the regulatory owner rather than filling the gap with assumptions about a contractor’s duties or an automatic decision to create a new listing.

04Establish who supplied the exports and when

For a private device-listing review, use an evidence record that identifies the supplying person’s role, their relationship to the owner/operator, and the establishments covered. This is a proposed QA control, not an FDA export requirement. Apply attributable recording to the transfer: distinguish the person forwarding the files from the authorized owner/operator contact person or official correspondent connected to them.

For forwarded files, retain the forwarding chain and obtain confirmation connecting those specific files to that authorized contact. A familiar filename, supplier email domain or broker assertion is not a substitute. Record the owner-stated export time separately from the receipt time independently captured by the receiving organization. Following contemporaneous recording principles, preserve each timestamp’s origin and time zone where known; receipt establishes when the organization received the files, not when they were exported.

Hashes support integrity checks against the preserved files; they do not establish who exported them. Keep the source confirmation associated with the originals rather than relying on a renamed working copy.

Judge freshness against the relevant proprietary-name, establishment, activity or configuration change, not a universal age limit. An older snapshot may remain useful for explaining a historical decision yet be insufficient for a decision after a change. Record which event the snapshot precedes or follows and what remains unresolved. Where timing is uncertain, retain that uncertainty and seek owner confirmation or refreshed paired files rather than silently treating receipt as evidence of current status.

Private listing-evidence review
  1. 1
    Set scopeIdentify the configuration, establishment and intended evidence decision.
  2. 2
    Confirm provenanceConnect the supplying role, owner and export times.
  3. 3
    Preserve filesRetain both originals and their integrity references.
  4. 4
    Join recordsMatch Listing Number within the aligned evidence bundle.
  5. 5
    Assess associationsEvaluate activities, proprietary names and the owner's revision rationale.
  6. 6
    Resolve exceptionsObtain attributable clarification or replacement evidence.
  7. 7
    Record decisionRetain the human review outcome and reassessment triggers.
Proposed review sequence; the responsible owner resolves regulatory interpretation.

05Join the export tables without losing their context

For US medical-device listing downloads, FDA’s DRLM download guidance, step 5 describes dividing the download into two parts because of the amount of proprietary-name information. Treat the files as complementary records, not interchangeable versions of the same table.

For US medical-device listings, FDA’s Download Listings field table documents these headings: Owner Operator Number, Listing Number, Premarket Submission Number, Premarket Exception, Product Code, Device Name, Registration Number and Activities.

For US medical-device listings, FDA’s Download Proprietary Names field table documents these headings: Listing Number, Proprietary Name and Confidential Flag.

Reconcile without flattening the evidence

The following are proposed QA controls, not additional FDA export requirements. Within an owner-confirmed, time-aligned export bundle, join by Listing Number. Preserve identifiers as text; retain raw values beside any normalized comparison values. Record normalization rules so a reviewer can distinguish a formatting adjustment from a changed identifier. Keep source-file and source-row references for every matched result.

Do not assume one row, one proprietary name or one configuration per listing. Group related rows without discarding repeated keys. Compare complete rows before identifying genuine duplicates: different Registration Number, Activities or Proprietary Name values represent different associations to retain. A flat join can multiply rows; that multiplication is not evidence of additional devices or configurations.

This separation supports production context tagging without turning a local configuration reference into an FDA export field.

  • Unmatched listing rows: retain them as having no matching proprietary-name row in this bundle; do not conclude that no proprietary name exists.
  • Orphan name rows: retain the name and its provenance, but leave its establishment and activity context unresolved.
  • Blank keys: exclude them from matching; never join blank values to each other.
  • Conflicting owner context: quarantine the proposed association for owner clarification rather than combining bundles on a matching number alone.

Preserve Confidential Flag exactly as recorded. Apply the organization’s access controls to the files and derived views without inventing flag meanings or treating an unexplained value as permission to disclose.

Evidence records and relationships

Export bundle

Local provenance for the paired files.

  • bundle_id
  • supplier_role
  • owner_confirmation
  • exported_at_reported
  • received_at
  • file_hashes

Listing row

FDA fields retained with source-row references.

  • Owner Operator Number
  • Listing Number
  • Premarket Submission Number
  • Premarket Exception
  • Product Code
  • Device Name
  • Registration Number
  • Activities

Proprietary-name row

Joined within the same evidence bundle.

  • Listing Number
  • Proprietary Name
  • Confidential Flag

Public observation

Separately captured public-view context.

  • captured_at
  • query_terms
  • source_url
  • observed_fields

Configuration assessment

Owner rationale, references and human decision.

  • family_reference
  • revision
  • evidence_references
  • owner_rationale
  • decision
  • approved_by
Proposed local records surround unchanged FDA export fields; joins do not determine configuration coverage.

06Read establishment activities and names together

For US medical-device listing on the cleared-or-approved submission path, FDA’s Initial Registration instructions, A, step 3 describe entering proprietary names and identifying activities performed on or to the device. The following reconciliation is a proposed QA review practice, not an FDA activity classification.

Compare recorded activities with actual operations

Compare the relevant Registration Number and Activities values with the owner’s description of the establishment’s actual work. Retain activity wording exactly in the review record; put its interpretation in a separate field rather than replacing it with an internal supplier category. This preserves the distinction between what the export records and what the reviewer concludes.

For the fictional DL-F17 revision D family, contract packaging describes the establishment’s business role. It does not, by itself, determine a particular FDA activity. Identify the actual packaging operations, including what is handled and whether packaging or labels are changed, then route the activity interpretation to the responsible regulatory owner. Keep an unexplained mismatch open rather than treating the supplier description as a substitute for the recorded activity.

Distinguish name differences before concluding

  • Spelling or formatting difference: preserve both strings and document any normalization rule used for comparison.
  • Former name: identify it as historical rather than treating it as the proposed name.
  • Additional name: record its presence separately; do not assume it replaces another entry.
  • Absent name: state that the proposed name was not found in the joined private records under review.

Write findings as bounded observations: the export associates the identified establishment with the recorded activity, or the proprietary-name table contains the proposed name. Record unresolved associations separately from confirmed matches. Use contemporaneous recording to capture the comparison and rationale when performed, without silently changing the underlying evidence.

07Relate the records to the controlled configuration

Start the owner assessment by identifying the controlled family or configuration, its revision, proposed proprietary name, relevant establishment and change under review. Reference the applicable configuration specification, rather than relying on a family nickname. State the intended decision first: whether the identified listing evidence supports the proposed association for that configuration and change.

Keep this assessment separate from the export join. The join establishes associations among exported rows; the owner’s assessment explains why those associations are relevant to the controlled configuration. A recorded proprietary name or establishment activity is an observation. Its relevance to a revised packaging specification, label or device configuration is a reasoned conclusion.

  • Record the owner’s rationale and the configuration documents considered, including revision identifiers and any relevant supplier change notification.
  • Reference the specific exports and rows relied upon, distinguishing recorded-name and recorded-activity findings from conclusions dependent on the configuration assessment.
  • Capture unresolved questions, the responsible owner, reviewer identity and decision date; explain what additional evidence would resolve each open question.

Use the following proposed evidence-review outcomes, each with a documented reason and responsible owner:

OutcomeMeaning for this assessment
SupportedThe observations and owner rationale support the stated association.
UnresolvedMissing, stale or ambiguous evidence prevents a conclusion.
Not supportedThe reviewed evidence contradicts the proposed association or the owner’s rationale does not substantiate it.

Do not build a fixed configuration-to-number cardinality into this review method. A changed name or revision calls for the appropriate owner assessment, not mechanical assignment of an existing or replacement listing number. Keep these evidence outcomes distinct from the organization’s separate product disposition process; route any disposition question to its designated decision-maker.

08Worked cases: DL-F17 revision D

All cases below are fictional historical illustrations. Shared assumptions: family DL-F17 is being assessed at revision D; the previous proprietary name is FableCare Kit; the proposed name is FableCare Pack; and Fable Packaging is the contract packaging establishment. No actual listing numbers, registration numbers, dates, customer identities or account details are used.

The units of review are exported listing rows, proprietary-name rows and the owner’s controlled configuration assessment. Decisions are qualitative, not based on invented numerical acceptance limits. Each case separates what the records show from what the responsible owner concludes about the proposed configuration.

Evidence objectConcrete fictional observationInterpretive boundary
Public capture before owner assessmentSearch displayed the Fable Packaging establishment name and the earlier FableCare Kit device name; no listing number was displayed.The capture establishes the strings observed at that time, not revision D coverage.
Private export pair after the proposed-name changeAuthorized official correspondent supplied both original files together and confirmed their common snapshot. Listing row used symbolic key KEY-F17 and establishment symbol EST-PACK; proprietary-name row used KEY-F17 and FableCare Pack.KEY-F17 and EST-PACK are nonnumeric teaching placeholders, not real FDA identifiers or fields added to the export.
Work descriptionRevision D work order described placing an already sealed device package into a revised outer carton and applying the controlled carton artwork; no device assembly or opening of its sealed package was described.These are fictional operations to compare, not a classification or instructions for performing packaging.
Activity observationThe preserved Activities cell was labelled ACT-A in this illustration; its actual regulatory wording would remain in the private original.ACT-A is a symbolic stand-in, not an invented FDA activity category. A public teaching example does not disclose private values.
Owner interpretationThe owner assessment specifically compared the closed-package outer-carton work, revision D packaging specification and proprietary-name transition with the preserved activity wording and paired rows.The reviewer accepted this bounded association only after the owner explanation addressed those operations; the export join itself supplied no revision decision.

The public name observation preceded the private snapshot; that relative timing supplied a coherent explanation for the different names without treating the public capture as a current private listing record. The reviewer retained the public capture, both private rows and the owner explanation as three evidence objects. The proposed name existed in the private row, while the revision relationship came from the controlled assessment. No real listing number, submission number or proprietary account information is reproduced. An unchanged product-code value would not answer either the name-transition question or the activity comparison.

Case A: aligned evidence

  • Assumption: an authorized owner/operator contact supplies a time-aligned listing and proprietary-name export pair for the review state.
  • Observed evidence: the private tables join by Listing Number; the name rows include FableCare Pack. The relevant establishment and activity values are retained with their source rows, alongside the provenance identifying Fable Packaging.
  • Decision boundary: these are recorded observations. The owner’s separate rationale explains why the described packaging work corresponds to the retained activity values and how the records relate to DL-F17 revision D.
  • Responsible action: the owner documents that assessment; QA links it to the reviewed pair and controlled configuration through the proposed requirements traceability record.
  • Closure condition: close the evidence-review task when the documented rationale addresses both packaging work and revision relationship, and the reviewer accepts that bounded association. Preserve the observations separately from the conclusion.

Case B: stale proprietary-name evidence

  • Assumption: the listing file relates to the later review state, but its paired proprietary-name file reflects the earlier FableCare Kit state.
  • Observed evidence: the private join retains FableCare Kit, while the controlled revision D proposal identifies FableCare Pack. The file provenance shows that the pair represents different review states.
  • Decision boundary: preserve this as a stale-name evidence mismatch. Do not edit the old name to make the join appear current, or infer that a replacement listing is necessary.
  • Responsible action: QA requests an aligned pair from the authorized source. The owner assesses the name transition and explains which records support the proposed name.
  • Closure condition: review the aligned replacement pair and the owner’s name assessment together. Retain the original mismatch and connect it to the resolution rather than overwriting its history.

Case C: unresolved establishment activity

  • Assumption: the proposed FableCare Pack name appears in the private name rows, but the establishment/activity association does not support the owner’s description of Fable Packaging’s work.
  • Observed evidence: the name matches; the activity association remains unexplained. Preserve the actual exported values and the separate description of the packaging operations.
  • Decision boundary: a matching name does not resolve this discrepancy. Keep the establishment/activity assessment unresolved rather than substituting the supplier’s contract packaging label for the exported activity.
  • Responsible action: route the discrepancy to the responsible owner for clarification or correction. Describe the actual operations, including any medical-device kitting, without assigning an activity from the supplier label alone.
  • Closure condition: retain unresolved status until suitable evidence and the owner’s explanation have been reviewed. Record whether closure followed clarification of the work description, corrected records, or both.

Case B changes only the proprietary-name snapshot: its row still joins on KEY-F17 but contains FableCare Kit and predates the proposed-name change, while the listing file reflects the later review state. EST-PACK remains the establishment symbol. The gap is the suitability of this mixed evidence pair for the new-name decision, not a demonstrated wrong listing number. The historical resolution received a replacement paired snapshot, confirmed its origin and compared the new name row with the retained name-change record; earlier mismatched files remained linked to the correction.

Case C keeps the later FableCare Pack row and common snapshot, but the retained activity wording does not align with the closed-package outer-carton description supplied for EST-PACK. A supplier statement merely saying contract packaging cannot resolve that difference. The owner response must explain the actual work relative to the recorded activity, or provide corrected evidence where the original record is wrong. Until that comparison is supported, the reviewer leaves activity applicability unresolved even though the proprietary name matches. This limits the evidence-review conclusion without manufacturing a regulatory classification or a release decision.

The result can be read back dimension by dimension: provenance attributable; snapshot relationship explained; proposed name observed privately; establishment symbol matched within the bundle; activity interpretation and configuration rationale separately documented. A later reviewer can disagree with an interpretation without disputing the captured string. Conversely, a correction to an exported row may require reconsidering the conclusion that relied on it. Retaining these differences makes targeted reassessment possible: a name-row replacement need not erase the already documented public observation, and an activity question need not invalidate every unrelated field in the pair.

09Preserve exceptions through import and correction

Use separate records for original files, parsed source rows, normalized comparison values and approved assessments. Assign local bundle and row references to connect these layers without overwriting imported evidence. Preserve raw Listing Number values; keep comparison transformations separate and traceable.

For system-neutral integration, link the evidence bundle to controlled documents, configuration records and supplier records. When information moves between systems, carry its file and row references, export dates, owner attribution and assessment status. These data integrity controls keep an unresolved association from becoming accepted merely through import.

Failure modeReview riskRecovery action
Missing proprietary-name fileIncomplete name reviewObtain companion file; repeat name checks.
Mixed export timesInconsistent snapshotsObtain aligned exports or documented reconciliation.
Unconfirmed forwarding chainUncertain attributionConfirm origin with authorized owner contact.
Unmatched listing keyUnsupported associationCheck raw keys and file completeness.
Unexplained repeated keySilent row lossPreserve rows; resolve meaning before consolidation.
Stale proprietary nameOutdated name associationObtain owner clarification or replacement evidence.
Unresolved establishment activityUnsupported activity associationObtain establishment-specific clarification; reassess.

Under this proposed local workflow, identify each issue, assign an owner, receive clarification or replacement evidence, repeat affected checks and record which assessment supersedes the prior decision. Retain prior evidence and the reason for supersession in the audit trail. Close only the exceptions supported by the new review; leave others unresolved. This is a proposed QA control, not a universal legal requirement.

10Close the review with a bounded decision

Use the following questions as proposed QA closure controls, not prescribed FDA acceptance criteria. Close against the defined evidence-review scope, rather than treating a completed checklist as a broader product decision.

  • Is the supplying authority attributable? Record the contact’s identity, represented owner/operator and basis for authorized sharing.
  • Are both files aligned? Identify the export pair, dates and any differences affecting whether the files can be assessed together.
  • Is the establishment association clear? State which establishment the finding concerns and flag ambiguous associations.
  • Are the relevant activities and names accounted for? Identify matches, omissions and discrepancies without treating a familiar supplier name as confirmation.
  • Is the configuration rationale documented? Reference the owner’s assessment connecting the controlled family revision to the reviewed records.
  • Are unresolved items assigned? Give each exception an accountable owner, next action and disposition status; distinguish administrative closure from an accepted association.

Keep the decision reconstructable

The minimum decision record contains the review scope, evidence references, findings, owner rationale, unresolved exceptions, responsible reviewer and approval record. Identify the configuration and establishment within scope. Separate observations made directly from the files from owner-reported facts: a name appearing in an export is an observation; an explanation of why that name covers the revision is an attributed owner assessment.

State the bounded conclusion: what association the evidence supports, what remains unresolved and what falls outside this review. Identify the human decision-maker and record their dated approval of that conclusion. Where uncertainty remains, specify its effect on the decision rather than burying it in attachments.

Trigger reassessment for a revised proprietary name, changed establishment work, replacement export pair or configuration change. Set timing through the organization’s documented risk and change-control process, considering the affected decision. Retain superseded assessments with their evidence references and replacement relationship so a later lookback review can reconstruct the basis of the earlier conclusion without substituting today’s records.

Frequently asked questions

Q.Can a broker obtain the listing number from FDA's public registration and listing search?+

No. For US medical devices, FDA’s listing-download guidance states that listing numbers are not publicly available; the establishment’s owner/operator contact person or official correspondent may download and share listing information with brokers. A practical review therefore separates public establishment information from privately shared listing records. Ask the authorized contact for the relevant exports rather than treating a public search result, establishment registration number, or broker’s transcription as the source of the listing number.

Q.Whose confirmation should accompany listing files forwarded by a supplier?+

Ask for confirmation attributable to the registered establishment’s owner/operator contact person or official correspondent, rather than relying solely on the forwarding supplier. As a proposed review control, record who authorized sharing, which establishment the files concern, when they were captured, and whether either file was edited or filtered. Preserve the forwarding chain alongside that confirmation. This applies attributable recording to the files’ provenance without treating the supplier’s possession of them as proof of authority or currency.

Q.Can QA complete the review when only the Download Listings file is available?+

Not the proprietary-name portion of this review. For US medical-device records, FDA’s export guidance describes separate Download Listings and Download Proprietary Names files. QA can document its assessment of the available listing and activity information, but should leave name coverage unresolved until the companion file is obtained. Join the files by Listing Number while preserving unmatched records. A proposed exception-based review can distinguish completed checks from this outstanding evidence gap without implying overall acceptance.

Q.What should happen when the proprietary-name export still shows the previous name?+

Treat the previous name as a reconciliation issue, not an instruction to overwrite the export. In the fictional historical DL-F17 revision D case, compare the export’s capture date with the revised name’s effective date and request the owner’s explanation of the transition. Preserve the original file, the explanation, and any replacement export. Use the relevant supplier change notification to connect the name transition to controlled records, then document whether the mismatch is historical, unresolved, or corrected.

Q.How should a contract packaging establishment be assessed when its activity entry differs from the described work?+

Compare the establishment identity and recorded activity with the actual packaging work described in the agreement and process records. For US medical-device listing, FDA’s instructions direct users to identify activities performed on or to the device. As a review practice, ask the owner to explain the mismatch and assess the applicable activity category; do not assign duties from the contractor’s title alone. A job traveler can help describe the work, but cannot resolve its regulatory categorization.

Q.What evidence connects DL-F17 revision D to the listing records being reviewed?+

For the fictional historical DL-F17 revision D review, request an owner-approved assessment connecting the controlled configuration, revised proprietary name, packaging establishment, and relevant listing records. Identify the configuration documents and their effective status, then explain why the selected records cover the assessed work and marketed identity. A configuration specification provides the technical reference for that assessment. Treat the relationship as a documented conclusion, not a match generated solely from the family name or listing number.

Q.Does a proprietary-name change by itself establish that a new listing is needed?+

Do not use the name change alone as a decision rule. For US medical-device listings, FDA’s change instructions direct users with listing changes to update their listing information. As a review practice, ask the owner to assess whether the change concerns only the marketed name or accompanies changes affecting the listing decision. Record that rationale through change control, including the affected records and follow-up evidence, rather than automatically creating a new listing-to-configuration relationship.

Q.How should reviewers handle exports captured at different times or repeated listing keys?+

Keep each original file and its capture context separate. For differently dated exports, ask the owner whether intervening changes affect the proposed join; request a contemporaneous pair when the relationship remains uncertain. For repeated Listing Number values, inspect the associated names, establishments, and activities before combining rows. Repetition alone is not a sufficient reason to delete a record. Document the join method, unmatched rows, and resolution decisions as part of the data integrity review.

Primary sources

  • fda-current-how official readable web retrieval; direct automated fetch limited
  • current-part807 official readable web retrieval; direct automated fetch limited
  • FDA FURLS DRLM listing export official document
Software that covers Device Listing Number
V5 Ultimate (FDA Compliance)
V5 Ultimate is a single-platform FDA compliance system for US manufacturers regulated under 21 CFR — pharma (210/211), medical…
Talk to us about Device Listing Number

Want to see how Device Listing Number could fit into your own records and workflows? Explore the related V5 pages or talk to our team about what applies to your operation.

Start free
Back to glossary
Related terms
  • → FDA Product Code
  • → Medical Device Classification
  • → Configuration Specification
  • → Change Control

Next Step

Try V5 with your own records, or ask a question first. Ask V5 opens with an editable question; nothing is sent until you choose to.

Start your free trial Browse All Features

Showing the site for the United States. Local spelling, dates and prices are applied automatically; change the language at the top of the page.

V5 Ultimate
Ultimate

Warehouse, quality and manufacturing software for regulated operations.

ProductIndustriesPricingResourcesSecurity & TrustCompanyLegal Centre

© S.G. Systems, LLC