Release for Supply
Release for Supply is an authorised person’s batch-specific certification for the supply of a finished medicinal product in Australia.

On this page · 11 sections
- 1What the final Australian release decision means
- 2Match the medicine and manufacturing steps to their authorisations
- 3Assign sponsor, manufacturer and authorised-person record responsibilities
- 4Build an evidence package that supports the final decision
- 5Carry the complete RFFP history into final RFS
- 6Separate evidence review, signed disposition and stock status
- 7Worked case: MED61 reaches a documented final decision
- 8Worked case: recover an incomplete or inconsistent handoff
- 9Keep another batch or later alteration outside the existing decision
- 10Connect records without losing identity, revisions or ownership
- 11Review the process by reconstructing an actual decision
How does Release for Supply apply to your shop floor?
Pick your industry and scale — Ask V5 rewrites the definition in your context, gives a worked example, and shows what V5 does on day one.
01What the final Australian release decision means
Release for Supply is an authorised person’s batch-specific certification for the supply of a finished medicinal product in Australia. TGA’s Australian RFS requirements describe this certification before supply. This article follows the final decision for an ARTG-registered finished medicine, especially where manufacturing records arrive from several sites.
Release for further processing (RFFP) has two categories in TGA’s multisite guidance: release of an intermediate or bulk product to the next manufacturer in the supply chain, or release of finished product that requires alteration for Australian distribution. Those arrangements belong in the GMP agreements. An upstream RFFP document therefore needs a defined scope: what product and batch it covers, which manufacturing steps were completed and which manufacturer receives it. Neither category means that receipt at the next site is automatically final Release for Supply.
| Term | Record or decision being discussed | Boundary in this article |
|---|---|---|
| Release for Supply | Authorised person’s batch certification | Final Australian finished-medicine decision |
| RFFP | Upstream release handoff | Feeds the final review; not its substitute |
| Generic batch release | Batch release terminology | Broader operational label, not a precise RFS record |
| EU QP certification | European certification terminology | Outside this Australian record model |
| GMP clearance | Manufacturing-authorisation evidence | Not the batch-specific final decision |
| Commercial dispatch | Stock movement | Not the certification record |
Keep European QP certification questions with the relevant European regulatory owner and consult the applicable current EU rules; do not use QP terminology as an alternative name for Australian RFS.
Regulatory explanations below are interpretations of TGA guidance, not quotations of binding legislation. The proposed record model, controls and fictional case decisions are suggested practice, not additional legal requirements.
04Build an evidence package that supports the final decision
For Australian medicinal-product RFS, TGA’s information-access list includes the relevant batch certificate of analysis (CoA), complete and reviewed product quality reviews (PQRs), ongoing stability data and updates, significant batch deviations and approved artwork specifications. These are evidence categories, not interchangeable proofs that a batch is ready for release.
For Australian medicinal-product RFS, that TGA list also includes product release and expiry specifications, marketplace feedback or signals, complaints, recalls, adverse events, and supply-chain details covering approved manufacturers, suppliers and contracts. Organise these administrative inputs separately from manufacturing and testing instructions: the index should show what was considered and the review conclusion, rather than reproduce operational methods.
For Australian medicinal-product RFS, TGA’s batch production and testing guidance expects production and quality-control documentation to be completed and endorsed by authorised staff, including OOS investigations for quality-control documentation. Document presence is therefore different from completed review and endorsement. An OOS investigation record marked received does not itself demonstrate that its review is complete.
For Australian medicinal-product RFS, TGA’s information-access list includes transport arrangements and any available transport data. That wording does not establish a universal transport-data specification.
Suggested evidence-index design
Use an index with document identity, applicable revision, batch relationship, owner, review status, review conclusion and unresolved issue. Identify the reviewer and link the conclusion to the underlying record. This makes an unresolved question visible without treating every uploaded file as accepted evidence.
The minimum RFFP documentation package is not just a transfer-status report. TGA identifies product name, product code and batch number, together with substantive assurances about the steps performed. The package is printed on company letterhead and signed and dated by the authorised person; computerised decision recording also calls for attention to PIC/S Annex 11. Paper signatures remain an option. A scan, a dashboard acknowledgement or a receiving clerk’s name should not be represented as that authorised-person certification.
Identity and attribution
Product name, product code and batch number; company letterhead and authorised-person signature and date.
Manufacturing and resolved issues
Applicable Australian marketing-authorisation compliance; relevant deviations resolved; no outstanding investigations, complaints or other relevant quality, efficacy or shelf-life matters.
Shelf life and risk
Label storage conditions consistent with finished-product shelf life; quality risk management tailored to the situation.
Review programmes and access
Batch information added to the site PQR programme with annual review; established access to relevant PQR and ongoing stability data and reviews.
For MED61, AP61 checks whether each assurance actually applies to the identified steps and batch history, not merely whether TR61A and TR61B contain headings. The TGA package requirements include assurance that deviations which may affect quality, efficacy or shelf life have been resolved, and that no investigations, complaints or other relevant matters remain to be taken into account by the RFS authorised person. Where an upstream issue is disclosed, its assessment and implication for F61 need to be understandable. A generic statement from an unrelated product or batch cannot establish those assurances.
TGA also identifies the relevant batch CoA as part of the accumulating package, provided by the entity with GMP responsibility for compiling that batch’s testing results. The CoA documentation provision does not make an analytical report equivalent to the whole RFFP package. AP61 needs both the correct batch report and the manufacturing, issue-resolution and programme assurances. Site A’s manufacturing scope and Site B’s packing scope should be explicit so that a certificate covering one step is not read as certification of work done elsewhere.
05Carry the complete RFFP history into final RFS
For Australian multisite medicinal-product manufacture, TGA’s upstream-reliance guidance makes reliance on other authorised persons’ decisions conditional on an appropriate pharmaceutical quality system (PQS) and the conditions below. This is a consolidated interpretation of guidance, not a quotation of legislation or unconditional permission to delegate the final decision.
- Relevant authorisation access: every authorised person has full access to the marketing-authorisation parts relevant to the manufacturing steps at their site.
- Defined agreements: all partial manufacturers are covered by valid GMP agreements that define RFFP to the next manufacturer in the supply chain.
- Site-specific procedures: the PQS at each manufacturing site contains detailed information on release procedures.
- Attributable decisions: RFFP decisions to the next manufacturer are recorded through a legally valid signature; TGA gives paper signatures and electronic signatures in a validated electronic environment as examples.
- Accepted upstream system: the RFS authorised person has accepted the PQS used for RFFP, for example through supplier qualification.
- Fulfilled upstream responsibilities: each RFFP authorised person fulfils the documentation, review, signature and onward-information responsibilities described in the guidance.
For Australian multisite medicines, TGA’s RFFP documentation-transfer guidance expects the final RFS authorised person to receive all RFFP documentation before RFS: each site passes the batch’s documentation, including preceding manufacturing-step RFFP documents, to the authorised person at the next site. For Australian multisite medicines, that guidance also expects relevant product quality review (PQR) data to reach the manufacturer performing RFS.
Suggested handoff control: use a cumulative index linking each upstream decision to its site, batch identity, signatory and supporting batch record. Mark whether each entry has been received and reviewed, rather than treating the latest transfer document as a substitute for the preceding history. This makes missing links visible without duplicating every manufacturing record in the index.
Under Valid GMP agreements, TGA expects agreements to include an obligation on providers of bulk or intermediate product to notify recipients of significant production-process deviations, OOS results, GMP non-compliance, investigations, complaints and other matters relevant to the RFS authorised person. This expectation is part of the Australian multisite guidance, not merely a suggested communication field. For MED61 the agreements should establish how Site A and other relevant providers notify downstream recipients of such issues, including information needed by AP61. A provider cannot substitute a blank exception box for communicating a known relevant issue.
The suggested tracking fields are a separate layer: sender, issue reference, affected batch, receiving owner, acknowledgement and AP61 routing. They can help demonstrate that the agreed notification route worked, but TGA does not prescribe those database column names. Use attributable recording to preserve who supplied the information and what changed. If a notification arrives after the original handoff, keep its relationship to that handoff visible and assess its relevance rather than silently replacing the earlier assurance.
06Separate evidence review, signed disposition and stock status
For Australian medicinal-product RFS, TGA’s definition describes performance through a legally valid signature of an authorised person. The administrative workflow below is a suggested sequence for the fictional registered-medicine case RFS-61, not a universal release procedure prescribed by legislation.
The proposed control preserves human approval: receiving all files does not automatically release stock, and no software status constitutes an authorised person’s decision. In RFS-61, the stock action follows the documented final RFS decision. Container status tracking then records the associated inventory state, rather than substituting for that decision.
TGA’s PQR guidance gives the release assessment a broader product-quality context. GMP agreements identify who compiles the complete PQR, how relevant data reach that compiler, how the RFS authorised person accesses the full PQR as required and how an inspector obtains it when the RFS manufacturer is not the compiler. Normally each contract manufacturer prepares data for its own manufacturing steps and submits relevant data to the RFS manufacturer, which collates complete PQRs. An alternative compiler can be another manufacturer or the sponsor if the applicable agreements clearly define the arrangement.
- Manufacturing contributorsEach site prepares relevant PQR information for its own steps and communicates it through the agreed route.
- Named complete-PQR compilerRFS manufacturer normally collates; an alternative manufacturer or sponsor can compile under clearly defined agreements.
- Authorised-person accessAP considers batch results in the context of PQR findings and can obtain full PQR information as required.
- Inspection retrievalThe agreement provides inspector access when the RFS manufacturer is not the compiler.
This is not a requirement to freshly compile an entire PQR for every lot. The batch package includes assurance that manufacturing information and data have entered the site PQR programme and that annual review is part of that programme, together with the mechanism for access to relevant reviews and stability information. Distinguish that programme assurance from the actual current PQR findings AP61 must consider. A fictional document reference or access contact may help navigation; neither replaces the relevant reviewed information or proves that the agreed retrieval mechanism works.
07Worked case: MED61 reaches a documented final decision
Assume MED61 is a fictional ARTG-registered finished medicine. The applicable manufacturing arrangements cover every activity below, and MA61v3 is the applicable marketing authorisation revision. Site C undertakes the final RFS decision through authorised person AP61. All identifiers are fictional internal labels, not regulatory approval numbers. The following review describes the evidence AP61 would examine before a satisfactory fictional decision; it does not report actual production, testing or a real regulatory approval.
| Site and activity | Batch identity | Decision evidence carried forward |
|---|---|---|
| Site A: bulk manufacture | B61 | TR61A documents Site A’s upstream RFFP handoff. |
| Site B: primary packing | B61 → P61 | TR61B documents Site B’s handoff and carries the preceding RFFP history, including TR61A. |
| Site C: Australian secondary packing | P61 → F61 | AP61 reviews the linked package against MA61v3 before signing the final decision record RFS-61 for F61. |
The bulk-to-pack traceability chain connects B61 to P61 to F61 without treating those identifiers as interchangeable. In this case, the finished batch record links to both transfer records and the applicable authorisation revision. TR61B does not replace TR61A: it carries the earlier history into AP61’s review. The earlier RFFP records remain upstream decisions, not the final disposition of F61.
AP61 first matches the product name MED61 and its product code to the batch identifiers in the signed and dated upstream packages. TR61A identifies Site A’s B61 manufacture; TR61B identifies Site B’s P61 work and the B61 relationship. AP61 checks the assurances for the steps each site performed against MA61v3, including resolved relevant deviations, investigation and complaint implications, label storage and shelf-life consistency, and the applicable quality-risk assessment. AP61 also checks the relevant batch CoA and the evidence that batch data entered the PQR programme. These substantive statements—not optional receipt timestamps—explain why the package could support the final decision.
For this MED61 scenario, the sponsor supplies a signed and dated written finished-product statement summarising the currently approved shelf life and current status of ongoing stability testing. That is one of the alternatives in TGA’s shelf-life and stability statement guidance, selected here because the fictional case uses an established approved shelf life. The other alternatives concern initial finished-product stability data used to define shelf life or justification while initial long-term testing of listed medicines is undertaken. The scenario does not invent a shelf-life duration, testing date, result or acceptance limit. AP61 verifies applicability rather than accepting any document headed stability.
TGA separately addresses intermediate or bulk product stored for more than three months, with the relevant initial/ongoing-data summary or shelf-life justification. No such storage duration is assumed for B61 here; AP61 must establish whether that situation applies before choosing the required supporting statement. Nor does secondary packing automatically require new stability experiments. In the TGA secondary-packaging scenario, additional stability would not normally be needed if primary packaging and stability profile are unchanged and the relevant conditions are met. AP61 needs the applicable assurance and risk basis, not an unsupported inference from the words secondary packing.
For the MED61 record arrangement, the GMP agreements name Site B as the complete-PQR compiler, with Site A contributing bulk-manufacture data and Site C contributing relevant secondary-packaging information. This is a fictional alternative arrangement permitted by TGA’s compilation guidance, not a universal assignment to a primary-packing site. AP61 confirms that all applicable agreements identify that compiler, contribution route and access arrangements. Site C does not need to rebuild the entire review for F61; it needs relevant findings in the release assessment and usable access to the full PQR when required, including inspector retrieval.
The same review checks the contractual route for relevant notifications from Site A as a bulk provider. AP61 examines any notified deviation, OOS result, non-compliance, investigation or complaint against the batch assurances; if there are none to consider, that conclusion must come from the applicable evidence rather than the absence of an email. A sender name, acknowledgement time, internal stability-reference label and PQR access-contact field are optional tracking choices. The signed applicable statements, required assurances, notification responsibilities and accessible review evidence are the substantive TGA-guidance matters. An unresolved mismatch keeps the fictional decision open until its implications are assessed.
Use finished packs as the quantity unit. F61 contains 1200 packs, allocated as 800 packs plus 400 packs: 800 + 400 = 1200 packs. These are stock allocations within F61, not new manufacturing batches or additional release decisions. After AP61 documents the final RFS decision, the stock-status record references RFS-61 for both allocations. No bulk-yield calculation is implied.
08Worked case: recover an incomplete or inconsistent handoff
Consider an alternative review state for fictional registered medicine MED61 in case RFS-61: AP61 receives an unsigned TR61A, an obsolete marketing-authorisation reference, or an inconsistent batch identity. These are administrative findings, not test failures or experimental results. The following recovery approach is suggested practice, not a prescribed regulatory correction procedure.
Resolve the specific evidence defect
- Missing signature: AP61 holds the final decision for clarification with TR61A’s upstream record owner. That owner arranges an attributable signed transfer; the recipient does not fabricate the upstream signature. Retain the previous version and make the replacement relationship visible. Apply attributable recording so the correction identifies who took responsibility rather than merely showing that another file arrived.
- Obsolete authorisation reference: the sponsor’s designated contact clarifies whether MA61v3 applies to the manufacturing steps and batch under review. The affected review is then revisited against that clarification. Replacing the reference alone does not establish that the earlier assessment remains valid.
- Batch-identity mismatch: the relevant manufacturing owners reconcile site A’s bulk batch B61, site B’s primary-pack batch P61 and site C’s secondary-pack batch F61. AP61 resumes the final decision only after the relationship is explained and supported. Use the lot pedigree to locate the disputed link, not to assume that matching product names establish batch continuity.
Close the finding before completing the decision
09Keep another batch or later alteration outside the existing decision
In the fictional MED61 case, a record for batch B62 arrives beside the F61 package. This is a separate disposition question, not an extension of RFS-61. The common product name, or association with a Certificate of Analysis (CoA), does not add B62 to that decision. Keep B62’s evidence and disposition separate; record its arrival without changing the batch scope of RFS-61.
In the proposed record model, distinguish a bulk or intermediate transfer to another manufacturer from a finished presentation still awaiting alteration for Australian distribution. Describe the intended downstream work and link it to the relevant batch, rather than treating every onward movement as the same kind of handoff.
For Australian multisite medicinal-product manufacture, TGA’s RFFP authorised-person guidance expressly refers to circumstances involving consecutive RFS steps. It therefore does not support a universal rule that a medicine can only ever have one RFS event or site.
As a practical scope control, if alteration is proposed after an existing RFS decision, assess the applicable manufacturing and release arrangements and check the current scenario 2 guidance before choosing a subsequent decision path. Preserve the earlier decision in the electronic release record, with its original scope intact. Treat it as evidence of that disposition—not unrestricted permission for later alteration. Link any subsequent assessment separately so reviewers can distinguish the original release from the proposed work.
10Connect records without losing identity, revisions or ownership
For Australian medicinal-product batch traceability, TGA’s documentation guidance expects records that allow the complete batch history to be traced in a comprehensible and accessible form.
| Evidence owner or relationship | What AP61 needs to retrieve |
|---|---|
| Sponsor → applicable stability statement | Signed and dated written statement covering the relevant finished-product shelf-life situation. |
| Bulk/intermediate provider → recipient | Relevant quality issue notifications under the valid GMP agreement. |
| Sites A and C → Site B compiler | Relevant PQR contributions and complete-review access under the fictional agreements. |
| Testing-results compiler → cumulative package | Relevant batch CoA with the correct batch relationship. |
For each handoff, record the source reference, received revision, receiving owner and reconciliation status. This gives quality-system integration an explicit document context while preserving the lot pedigree. Keep the reviewed revision identifiable even when a newer package becomes available.
Use a reconciliation queue for integration failures: an attachment without a usable batch relationship, a reviewer opening a superseded package, an unretrievable cross-site reference, or a missing acknowledgement. Assign each item to a named receiving owner, with the originating site identified for resolution. Record revision acknowledgement separately from receipt so that delivery is not mistaken for acceptance of the revised package. Route unresolved items through the case’s clarification process above; close the queue item with the corrected relationship or acknowledgement and an attributable resolution.
11Review the process by reconstructing an actual decision
Use a retrieval-based walkthrough as a suggested implementation test, not an additional regulatory inspection requirement. For the Australian registered-medicine process described above, ask a reviewer to follow actual references rather than accept a checklist marked complete.
- Start with a stock disposition. Trace it to the signed electronic release record, the identified finished batch, its upstream manufacturing history and the evidence basis used for that decision. Can the reviewer explain the connection without relying on someone’s memory?
- Test organisational boundaries. Ask who answers an authorisation query, who corrects a transfer, who assesses that correction and who executes the resulting stock disposition. Record unresolved responsibility gaps with named owners and escalation routes; do not treat an unanswered handoff as a completed review.
- Walk through the complete MED61 handoff, the deficient transfer and the unrelated B62 batch. Check whether the reviewer can explain why a decision remained held, follow the corrected record back to its retained predecessor through the audit trail review workflow, and show why the unrelated batch remains outside the decision.
Keep the exercise within administrative evidence handling—not manufacturing, laboratory or stability protocols. Its useful output is a documented account of broken references, unclear ownership and unresolved exceptions, with responsibility assigned for addressing each gap.
Frequently asked questions
Q.Can a sponsor assemble the evidence package while a different manufacturer retains responsibility for the RFS decision?+
Yes—as a suggested administrative arrangement, the sponsor can assemble the package without taking over the manufacturer's RFS decision. For Australian registered medicines, TGA's information-access guidance assigns the manufacturer and, where different, sponsor responsibility for ensuring the RFS authorised person's access to relevant information. Practically, identify the package compiler separately from the decision-maker, assign outstanding items to named owners, and identify the reviewed package version. A contract-manufacturing responsibility map helps distinguish document collection from decision ownership.
Q.How should an outsourced laboratory report be linked to the correct multisite batch history?+
Use a batch-specific cross-reference rather than matching only the product name. A practical index links the laboratory report identifier and version to the submitted sample, originating manufacturing batch, relevant packaging batch and associated transfer record. For Australian multisite medicines, TGA's Certificate of Analysis guidance expects the relevant batch CoA to enter the accumulating RFFP package. Keep any explanation of different site identifiers alongside the report; bulk-to-pack traceability helps reviewers distinguish a legitimate identifier change from an unresolved batch mismatch.
Q.What should the evidence index show when a relevant PQR or stability update changes during review?+
As a practical version-control approach, show the previously reviewed document, its replacement, when the update became available, and who assessed its relevance to the pending RFS decision. Identify the affected product, batches or review period rather than assuming every update changes the disposition. Record whether the change prompted additional questions, altered the assessment or had no relevant impact, with reasons. Retain the earlier reference in the history and identify the PQR or stability summary version actually considered at decision.
Q.How can available transport information be incorporated without turning the RFS record into a transport protocol?+
For Australian registered medicines, TGA's information-access guidance includes transport arrangements and any available transport data among the information accessible to the RFS authorised person. A practical record can identify the shipment leg, affected batch, information reviewed and assessment outcome, while linking to the underlying transport record. Describe gaps explicitly rather than treating unavailable data as satisfactory results. If a temperature excursion is relevant, reference its assessment and disposition; keep monitoring instructions and transport operating methods in their own controlled documents.
Q.What is a practical way to record review of an upstream investigation without copying the entire investigation into the decision record?+
Use a concise review entry linked to the controlled investigation. As suggested practice, identify its owner, reference, version, affected batches and status, then summarise the issue, relevant conclusions and implications for the batch under RFS review. Record the reviewer's assessment and any unresolved questions separately from the upstream investigator's conclusion. A deviation record reference preserves context without duplicating the full narrative. Where the investigation covers several batches, explain why its findings apply to this batch rather than relying on its closure status alone.
Q.How should absence or replacement of the named authorised person be handled in the record trail?+
For Australian registered medicines, TGA's appointing authorised persons guidance recognises that a manufacturer may have more than one RFS authorised person. As a practical handover control, record the replacement person's identity, the documented basis and scope of their authority, the handover date and outstanding review questions. Preserve earlier review entries under their original authors; do not relabel them as the replacement's work. Link relevant training records, and identify who actually made the final decision.
Q.How can an RFS evidence export remain intelligible to a reviewer outside the originating site?+
For Australian registered medicines, TGA's batch-traceability guidance expects records that enable the complete batch history to be traced in a comprehensible, accessible form. A practical export includes an index, a site-and-batch identifier map, document versions, signatory identities and explanations of local status terms. Make referenced attachments accessible outside the originating application and distinguish transfer decisions from final RFS. Check the electronic batch record export as a standalone package, including whether its references and chronology remain understandable.
Q.How should a complaint received after RFS be linked back to the evidence considered at release?+
As suggested record-management practice, create a dated link from the complaint to the affected finished batch, its RFS decision and the package version considered at release. Preserve that original decision record rather than rewriting it to include information received later. Record subsequent assessments separately, identifying what became known after release and whether it changes the understanding of earlier evidence. Link related batches only where the assessment supports that connection. This supports recall readiness without treating the complaint itself as a predetermined recall decision.
Primary sources
Want to see how Release for Supply could fit into your own records and workflows? Explore the related V5 pages or talk to our team about what applies to your operation.