See the trend.Notice the drift.Review the signal.

Every result lands on a control chart for its method, checked against Westgard rules against a locked, signed baseline.

The pattern emerges across results.

AI assists.People check.
Start free trial
Chemist in hair cover, mask, safety glasses, lab coat and gloves reviewing a control chart on a tablet next to an HPLC instrument
See it work

Follow one method

Every result on its method's chart

Results plot by method on a Levey-Jennings chart.

How lab SPC works: charts, baselines, rules and printouts

1. Every result on its method's chart

Results plot by method on a Levey-Jennings chart.

See mean, standard deviation and point count.

Compare the spread with what a normal distribution expects.

List
All methods with their mean, SD, points and baseline in one list.

Charts use results recorded in V5 Lab & QC.

ASSAY-HPLC-01

Levey-Jennings

Points (90 days)
62
Mean (x̄)
100.2%
Std dev (σ)
0.9
Within ±1σ
69% · expect ~68%
Window
30 · 90 · 180 · 365 days

One chart per method.

2. Limits from a Locked Baseline

Recompute the baseline from a window of results.

Lock it with an e-signature and a reason.

Re-baselining needs its own reason.

Capability
Process capability is shown alongside the chart.

Without a locked baseline, Westgard evaluation is off for that method.

Baseline

ASSAY-HPLC-01

Recompute
From selected window
Lock
E-signature
Reason
Required (Part 11)
Status
Baseline locked & signed
Re-baseline
New reason, new signature

No silent limit changes.

3. Westgard Rules on Every Save

Each result is checked as it is saved.

Mean shifts and out-of-control points are flagged.

Rejection rules open an OOS investigation automatically.

OOS
Investigation runs in OOS investigations.

Which rules apply is configured per method by your lab.

New Result

Rule check

Value
97.1%
z
−3.4
Flag
Beyond ±3σ
Rule
Rejection
Action
OOS-0019 opened

Evaluated server-side.

4. A Trend Printout for Review

Print the chart, flags and baseline for review.

Use it in periodic trend and management reviews.

Recent points list sits under the chart.

Review
Trends support annual product review and management review.

Interpreting a trend is your lab's job; V5 shows the data.

Trend Report

ASSAY-HPLC-01

Chart
Levey-Jennings
Flags
1 in window
Baseline
Signed 3 Sep
Distribution
±1σ / ±2σ / ±3σ
Output
Print PDF

Ready for a trend review.

V5 AI

AI and SPC & trending

Statistical limits are not AI predictions

SPC & trending

Statistical limits are not AI predictions

Ask V5 about chart inputs, specification limits and statistical signals. Calculated SPC measures are distinct from coming-soon process anomaly detection.

AI use & review
What's included

Everything in this feature

What lab SPC uses, and which plan each item needs. Compare plans

  • Levey-Jennings charts

    Enterprise

    Per method, 30–365 day windows.

  • Signed baselines

    Enterprise

    Locked with e-signature and reason.

  • Westgard rules

    Enterprise

    On every result.

  • Automatic OOS on rejection

    Enterprise

    Linked investigation.

V5 flags the drift. People decide what it means.

Sample report

Explore the sample records.

Open a sample report to review its contents, supporting references and how the record is built.

  • V5Ultimate

    Sample register

    Lab SPC trend (CSV)

    Test & release

    Lab SPC trend (CSV)

    CSV

  • V5Ultimate

    Sample report

    Continued Process Verification Report

    Quality system

    Continued Process Verification Report

    1 page · PDF

  • V5Ultimate

    Sample report

    Annual Product Review

    Test & release

    Annual Product Review

    2 pages · PDF

All sample reports and records
Free buyer guide19 pages · Online & printable · opens online

Quality Evidence & Management Review Buyer Guide

A 19-page guide to quality decisions you can show evidence for: management review, lab results, approved suppliers and customer document sharing.

What's inside
  • Management review: inputs to owned decisions, with a worked quarterly review
  • Lab results: specifications, out-of-specification investigation and release boundaries
  • Approved suppliers: scope, evidence, expiry and a lapsing certificate
  • Customer document sharing: approval, revision, withdrawal and portal evaluation

Plus Connected evidence map, RACI, implementation plan, RFP and scored checklist.

We ask for your name and email so we can handle this request. The full guide then opens on this site, ready to translate, print or save. Privacy policy.

Questions

Straight answers.

What buyers ask us first about Quality & Laboratory.

  1. Does V5 release product automatically?

    No. V5 gathers results and records for review, but a person in quality decides and signs the release.

  2. What does the lab side cover?

    Lab and QC covers sampling, instruments, methods, results and out-of-spec handling, with LIMS, lab notebook, stability and SPC on top. These are Enterprise features; see Compare details on the pricing page.

  3. Can we use V5 in a validated environment?

    For validation-controlled operations, V5's route is Enterprise private cloud with controlled upgrades and IQ/OQ support. Your team still validates V5 for its intended use.

Explore

More of the product

Start with one area. Add the rest when you are ready.

Try it with one method you watch closely.

Start a free trial or talk it through with us. No card needed.

Or (you can edit the question before sending).

Showing the site for the United States. Local spelling, dates and prices are applied automatically; change the language at the top of the page.