Investigational Device Accountability
Trace investigational-device quantities and identities through sponsor and investigator records without confusing a balanced total with complete evidence.

On this page · 11 sections
- 1Investigational Device Accountability
- 2Select the US Record Scope Before Designing the Ledger
- 3Separate Sponsor Shipment Records from Investigator Device Records
- 4Follow Events Without Losing the Original Receipt
- 5Link Device Identity, Events, Evidence, and Exceptions
- 6Worked Case: Forty Units and One Unexplained Device
- 7Worked Case: Six Kits Match in Count but Not Revision
- 8Exchange Records Without Creating Duplicate Movements
- 9Look for Errors a Balanced Total Can Conceal
- 10Retain the Evidence Against the Current US Rule
- 11Test the Ledger Through Evidence-Based Review
How does Investigational Device Accountability apply to your shop floor?
Pick your industry and scale — Ask V5 rewrites the definition in your context, gives a worked example, and shows what V5 does on day one.
01Investigational Device Accountability
Investigational Device Accountability is the reconciliation of sponsor shipment and disposition records with investigator receipt, use, return, repair, and other disposition records to explain device quantities, identities, and unresolved differences. Investigational device reconciliation is an alias for the same process.
What Investigational Device Accountability Establishes
This article addresses US sponsor–investigator device-movement evidence, not clinical trial conduct. The practical question is whether linked records explain where study devices went and which differences remain unresolved.
| Term | Record question | Boundary |
|---|---|---|
| Study accountability | What was shipped, received, used, returned, repaired, or otherwise disposed of? | Connects movements to evidence and unresolved differences. |
| Device history record | What manufacturing history belongs to the device or batch? | Manufacturing history does not replace study-movement evidence. |
| Device master record | What master specifications define the device? | Specifications do not establish actual study movements. |
| Physical inventory count | What is physically present at the count? | A stock observation does not explain earlier movements. |
| ISO 14155 | What is the broader good clinical practice framework for medical-device investigations? | Broader purpose than shipment-to-disposition reconciliation. |
Examples throughout use hypothetical inert devices. This public article excludes clinical records and patient information; it discusses restricted source references rather than publishing underlying clinical data. That is an editorial and information-handling boundary, not a statement of a particular privacy law.
02Select the US Record Scope Before Designing the Ledger
Start with a documented scope decision for the US investigational medical-device study, then select the record structure. As a proposed implementation control, keep that decision alongside the ledger specification: identify the investigation category, applicable record references, and any supplemental sponsor controls. A device description or a design history file is not a substitute for this investigation-specific assessment.
| US investigation category | Sponsor record reference | Investigator record reference | Accountability-register status |
|---|---|---|---|
| US significant-risk medical-device study | FDA IDE Records guidance: Sponsor Records for Significant Risk Device Studies; shipment and disposition records under §812.140. | FDA IDE Records guidance: Investigator Records for Significant Risk Device Studies; receipt, use, and disposition records under §812.140. | Separate sponsor and investigator record categories; the next section develops their field ownership. |
| US abbreviated nonsignificant-risk medical-device investigation subject to §812.2(b)(1) | §812.140(b)(4), including its reference to paragraph (b)(5). | §812.2(b)(1)(vi) directs the sponsor to ensure maintenance of records referenced in §812.140(a)(3)(i). | An expanded shipment-to-disposition register is proposed sponsor practice, not an automatic import of the significant-risk record categories. |
| US medical-device investigation qualifying under §812.2(c) | Part 812 exemption, except §812.119. | Part 812 exemption, except §812.119. | Assess separately; exemption is not an abbreviated NSR classification. |
For US significant-risk medical-device studies, FDA’s IDE Records guidance organises sponsor and investigator records under separate significant-risk headings. Its sponsor list includes shipment and disposition records; its investigator list includes receipt, use, or disposition records. This guidance organisation helps distinguish the two record owners without treating their records as interchangeable.
For US abbreviated NSR medical-device investigations, 21 CFR 812.140(b)(4) identifies sponsor records consolidated in one location and available for FDA inspection and copying, including the records in paragraph (b)(5). For these US investigations, paragraph (b)(5) covers adverse device effects, whether anticipated or unanticipated, and complaints.
For US medical-device investigations under the abbreviated NSR provisions, 21 CFR 812.2(b)(1)(vi) directs the sponsor to ensure that participating investigators maintain the records referenced in §812.140(a)(3)(i). Preserve that specific reference in the scope mapping rather than substituting the complete significant-risk accountability table.
For qualifying US medical-device investigations, 21 CFR 812.2(c) states that Part 812 does not apply except for §812.119. Do not determine qualification from a device description alone.
If a sponsor proposes an expanded NSR accountability register, document its reconciliation purpose and agreed ownership separately from the regulatory mapping. Specify who records movements, who supplies supporting evidence, and who reviews unresolved differences. Label these additions as sponsor-designed controls so reviewers can distinguish the selected operating practice from the abbreviated regulatory references.
03Separate Sponsor Shipment Records from Investigator Device Records
For US significant-risk investigational medical-device studies, 21 CFR 812.140(a) requires the participating investigator to maintain accurate, complete, and current records relating to their participation. For those US significant-risk investigational medical-device studies, 21 CFR 812.140(b) requires the sponsor to maintain accurate, complete, and current records relating to the investigation.
For US significant-risk investigational medical-device studies, sponsor shipment records under 21 CFR 812.140(b)(2) must include the consignee’s name and address, device type and quantity, shipment date, and batch number or code mark. Under that provision, sponsor disposition records for US significant-risk investigational medical-device studies must identify the batch numbers or code marks of devices returned to the sponsor, repaired, or otherwise disposed of by the investigator or another person, and describe the reasons for and method of disposal. Disposition identification and disposal explanation are separate information needs.
- For US significant-risk investigational medical-device studies, investigator records under 21 CFR 812.140(a)(2)(i) must cover device type and quantity, receipt dates, and batch number or code mark.
- For US significant-risk investigational medical-device studies, investigator records under 21 CFR 812.140(a)(2)(ii) must name all persons who received, used, or disposed of each device.
- For US significant-risk investigational medical-device studies, investigator records under 21 CFR 812.140(a)(2)(iii) must cover why and how many units were returned to the sponsor, repaired, or otherwise disposed of.
The following role matrix is a proposed operating arrangement, not additional regulatory job titles or recipient-qualification criteria. Sponsor recipient selection, tracking, and eligibility checks remain separate from investigator recording of actual recipients.
| Role | Source record ownership | Reconciliation contribution | Proposed review decision |
|---|---|---|---|
| Sponsor | Sponsor shipment and disposition records | Select and track intended recipients; document proposed eligibility checks | Confirm intended consignee details against shipment evidence |
| Investigator records owner | Investigator receipt, use, and disposition records | Record actual recipients and resolve site-source questions | Confirm site entries or document supported corrections |
| Custody personnel | Handover acknowledgments and physical-count evidence | Document observed transfers and quantities | Confirm observed facts; flag unsupported entries |
| Sponsor QA reviewer | Review findings and exception decisions | Compare sponsor and investigator evidence | Accept supported reconciliation or keep discrepancies open |
In this proposed arrangement, the sponsor QA reviewer requests clarification rather than silently rewriting site records. An audit trail review workflow can structure review of corrections: identify the source owner, the changed entry, its supporting reference, and the reviewer’s decision. Review acceptance does not substitute for the investigator’s source-record confirmation.
04Follow Events Without Losing the Original Receipt
For US investigational-device accountability, the following is a proposed ledger workflow, not a prescribed regulatory sequence. Preserve an event history alongside the current reconciliation snapshot: the history explains movements and corrections; the snapshot shows the cohort’s position at a stated review time. A receipt establishes the incoming cohort. Later events explain what happened to it without rewriting its original quantity.
Give each event a unique eventId, following a process event log approach. Link amendments to the original event rather than replacing it silently. Keep shipment date, receipt date, subsequent event date, record-entry time, and review time distinguishable. Record shipments and receipts contemporaneously; where entry occurs later, preserve both the actual event date and entry time rather than disguising the difference.
Use proposed states deliberately: recorded means entered; source-linked means connected to supporting records; disputed means evidence or interpretation remains unresolved; reviewed means a reviewer has assessed the entry. Keep review status separate from resolution status. A reviewer can acknowledge an unresolved exception without declaring the underlying device event complete.
Workflow: linked evidence events
| Sequence | Evidence carried forward |
|---|---|
| Expected consignment → sponsor shipment | Link the planned consignment to the actual dispatch record. |
| Sponsor shipment → site receipt | Compare dispatch evidence with site acknowledgment; preserve differences. |
| Site receipt → documented use or movement | Link each subsequent event to the received cohort. |
| Use or movement → return, repair, or other disposition | Attach supporting records; for disposal, document what occurred, not operating instructions. |
| Disposition evidence → discrepancy review | Identify unsupported movements and assign unresolved questions for follow-up. |
| Review → retained reconciliation references | Retain the snapshot’s event references, supporting records, amendments, and review decision. |
- Identify scopeRecord the study basis and applicable record references.
- Define consignmentIdentify destination, batch, expected revision, and accounting unit.
- Record shipmentLink dispatched quantity and shipment date to source evidence.
- Match receiptCompare site observations with the identified shipment line.
- Link later eventsAssociate use, return, repair, and disposition evidence.
- Investigate differencesAssign quantity, identity, or evidence gaps to owners.
- Record reviewSign the comparison and preserve open issues.
05Link Device Identity, Events, Evidence, and Exceptions
The proposed model below connects accountability records without merging their owners or meanings. Use the field mapping above for applicable regulatory fields; the additional identity and review fields here are proposed practice.
Entity figure: linked accountability evidence
| Relationship | Purpose |
|---|---|
| Study/site → shipment line | Places each dispatched quantity in its investigation and destination context. |
| Shipment line → device identity | Links the quantity to its type, batch/code, and optional finer identifiers. |
| Device identity → accountability events | Connects the identified cohort or unit to recorded movements and outcomes. |
| Accountability event → source references | Connects each assertion to its supporting record. |
| Unresolved comparison → reconciliation issue | Preserves the evidence gap and review responsibility. |
Keep quantityUnit, such as kit or individual device, separate from deviceType and batchCode. Record revisionObserved separately from those identifiers. An optional unitId supports unit-level or serial links where the sponsor chooses that granularity; serialization is not a prerequisite of this proposed model. In mixed-component shipments, define what constitutes a kit using the relevant medical-device kitting context, rather than silently treating components as complete kits.
Proposed revisionExpected identifies the version anticipated for that shipment line; revisionObserved records the version identified on the physical kit, with its evidence reference. A document revision alone does not establish the observed physical version. Preserve both values when they disagree.
For source evidence, capture sourceId, record owner, signed reference where applicable, original event date, entry time, amendment relationship, and access class. Signed references are a proposed reconciliation control, not an additional universal signature rule. Access classes distinguish operational references from restricted records; keep clinical and patient data off public websites.
Keep issue status separate from device-event status. Each issue records expected evidence, observed evidence, assigned owner, next evidence request, and reviewer decision. Changing an issue to resolved does not create a shipment, receipt, or disposition event.
StudySite
Establishes sponsor and destination context.
- studyId
- sponsorId
- siteId
- investigatorName
- consigneeAddress
DeviceIdentity
Distinguishes accounting identity from quantity.
- deviceType
- batchCode
- revisionExpected
- revisionObserved
- unitId_optional
- quantityUnit
Shipment
Defines the original outgoing cohort.
- shipmentId
- shipmentLineId
- consigneeId
- quantityShipped
- shipmentDate
AccountabilityEvent
Records an attributable device event.
- eventId
- deviceRef
- eventType
- quantity
- eventDate
- actorName
- reason
- method
- sourceRef
SourceEvidence
Preserves provenance and amendment relationships.
- sourceId
- recordOwner
- signedReference
- recordedAt
- amendmentOf
- accessClass
ReconciliationIssue
Keeps evidence gaps independently reviewable.
- issueId
- expectedEvidence
- observedEvidence
- assignedOwner
- status
- reviewerSignoff
06Worked Case: Forty Units and One Unexplained Device
Assume hypothetical sponsor ST-41 ships 40 identified inert device units, batch B-41, revision C, to authorised investigator Site A. Site A records receipt of 40 units. Recipient authorisation is a case assumption, not a legal qualification conclusion. All references below are illustrative; this is a proposed reconciliation method, not a regulatory field specification.
Investigator records owner Alex Chen assembles signed site source references linked to unique eventIds. Sponsor QA reviewer Dana Reed compares these with sponsor shipment and return evidence. Shipment event SH-A and site receipt event RX-A retain their respective contemporaneous shipment and receipt dates; neither date is replaced by the later reconciliation signature date.
At the selected cutoff, the categories below are mutually exclusive: each identified unit occupies one category. This is a cohort-accountability snapshot, not a claim that every documented use physically consumes a device.
| Reconciliation category | Units | Supporting reference | Review state |
|---|---|---|---|
| Used | 18 | USE-A: signed unit-linked use register | Accepted |
| Returned | 8 | RT-A: signed dispatch; RTR-A: signed sponsor receipt | Matched and accepted |
| Disposed | 2 | DSP-A: signed disposition record | Accepted |
| Unused and confirmed | 11 | COUNT-A: signed physical inventory | Accepted at cutoff |
| Unexplained | 1 | EX-A: signed exception referencing RX-A and COUNT-A | Open; Alex Chen owns follow-up |
The arithmetic is 18 + 8 + 2 + 11 + 1 = 40 units. The explained categories total 39 units, leaving 1 unexplained unit. Dana does not convert that unit to disposed merely to balance the ledger. The total reconciles only with the unresolved category visible; evidence closure remains incomplete. As with net-vs-gross reconciliation, the review preserves the difference rather than hiding it in an adjustment.
The sponsor’s receipt of 8 returned units, RTR-A, matches return event RT-A for this original cohort. It does not increase Site A’s original receipt of 40 units. Dana checks the returned unit identities against the dispatch reference rather than treating the sponsor receipt as another site delivery.
The review output is a signed reconciliation decision listing accepted source references, the remaining request for unit-specific location or disposition evidence, and Alex Chen as exception owner. Alex documents the site evidence; Dana signs the sponsor review decision with EX-A still open. Those signatures record accountability conclusions, not clinical authorisation or automatic release.
07Worked Case: Six Kits Match in Count but Not Revision
Assume a separate shipment contains 6 inert kits. Its manifest identifies all 6 as revision D, but the site observes 1 revision C kit and 5 revision D kits. Shipment and receipt quantities both equal 6: the count matches, while the revision evidence does not.
For this example, place the revision discrepancy on a proposed documentary evidence hold, separate from the quantity comparison. This status means the identity evidence awaits resolution; it is not clinical direction, a disposal procedure, or a recall instruction. Keep the confirmed receipt quantity unchanged while reviewing the affected kit.
Compare the manifest with observed kit labels, packing evidence, and attributable site observations. Apply attributable recording by identifying who observed the mismatch, when, and which shipment line and kit reference it affects. Link those observations to the discrepancy so a reviewer can distinguish a transcription problem from conflicting physical identification.
If verification establishes a manifest error, preserve the original and issue a linked correction identifying the reason, supporting evidence, and reviewer. Apply the manufacturing-versus-study-record boundary established above: the latest manufacturing master-document revision does not establish which revision physically arrived in this shipment. If identity remains uncertain, leave that issue open rather than substituting revision D because it is newer. Close the documentary hold only against evidence resolving the specific discrepancy.
08Exchange Records Without Creating Duplicate Movements
As proposed practice, connect sponsor shipping records, site accountability records, and sponsor return-receipt records through references held in a controlled evidence repository. Keep each source identifiable; importing its representation does not establish a new physical movement.
Match incoming records using study/site context, shipmentLineId, eventId, batchCode, event type, and quantity unit. Check for duplicate imports before aggregating quantities. Investigate a retry carrying the same source event identity as a repeat transmission, rather than automatically adding it. A site return dispatch and sponsor return receipt are distinct events linked to the same transfer, not interchangeable records.
| Incoming condition | Reconciliation treatment | Recovery evidence |
|---|---|---|
| Duplicate event | Exclude repeat transmission from quantity aggregation pending comparison. | Source identity, payload comparison, and duplicate decision. |
| Unmatched shipment line | Hold outside the reconciled event set; resolve the source relationship. | Rejected record, mapping error, and confirmed shipment-line reference. |
| Amended source record | Link the revision to its predecessor; avoid adding another movement. | Original and amended records, author, reason, and correction time. |
For a failed import, preserve the rejected record and error context. Have an identified owner correct the mapping or source through an attributable process, then reprocess it. Compare the resulting event identities and quantities with the intended source set; a successful import message alone is not a reconciliation decision.
Keep source event dates intact when records arrive late. Record later import and correction times separately, together with the amendment reason, in the audit trail. This preserves the distinction between when a movement occurred and when its record became available for review.
09Look for Errors a Balanced Total Can Conceal
For US investigational-device accountability, the following are proposed review controls, not additional regulatory requirements. Beyond the earlier balancing, revision, and duplicate-import examples, test whether totals preserve batch identity, quantity units, repair continuity, and retrievable evidence.
| Failure mode | Misleading result | Control | Evidence to inspect |
|---|---|---|---|
| Aggregation across batches | Opposing batch-level differences cancel in the study total. | Reconcile each batch and shipment line before aggregating; retain each difference separately. | Batch-level reconciliation, shipment-line quantities, and corresponding receipt records. |
| Kit and component quantities mixed | Unlike accounting units produce an apparently complete balance. | Declare the accounting unit for each line. Apply a conversion only where its basis is documented. | Declared units, kit composition records, and the documented conversion basis. |
| Repair entry replaces original identity | A returning device appears unrelated to the device sent for repair. | Link outgoing, service, and returning events while preserving the original device relationship. | Dispatch record, service record, return receipt, and any documented identity change. |
| Source reference breaks after migration | A populated link field suggests evidence remains accessible. | Test retrieval from the migrated reference and retain the old-to-new cross-reference. | Retrieval-test result, migration cross-reference, and the retrieved record’s identity. |
A unit class library provides a useful model for consistent quantity labels. Record the review result against the affected ledger line, so later reviewers can distinguish a checked relationship from an unchecked total.
10Retain the Evidence Against the Current US Rule
For US investigational medical-device records required by the relevant subpart, 21 CFR 812.140(d) requires the investigator or sponsor to retain records during the investigation and for 2 years after the later of two dates: the investigation’s termination or completion date, and the date the records are no longer required to support the specified submissions. Those submissions are a premarket approval application, notice of completion of a product development protocol, humanitarian device exemption application, premarket notification submission, and request for De Novo classification.
For US investigational medical devices, FDA’s IDE Records page gives a narrower retention summary naming PMA and PDP only. Use the current regulation above for the complete submission list and binding retention rule.
For US investigational medical-device records, 21 CFR 812.140(e) permits an investigator or sponsor to transfer custody to another person accepting responsibility under Part 812. FDA must receive notice not later than 10 working days after transfer occurs.
Proposed retention decision record
As an operational practice, document the retention decision separately from the accountability balance. Suggested fields are:
- Relevant dates, their supporting references, and the resulting retention calculation.
- Submission-support assessment, including any unresolved dependency rather than an assumed end date.
- Named decision owner and current records custodian.
- Retrieval location for the ledger and its linked evidence.
- For a custody change, the recipient’s acceptance and reference to the FDA transfer notice.
These proposed fields document application of the rule; they are not additional statutory fields. For electronic archives, keep the retention decision distinct from the separate 21 CFR Part 11 assessment.
11Test the Ledger Through Evidence-Based Review
Use these proposed acceptance tests for the accountability ledger, with each test linked to its intended record function through requirements traceability. For every finding, record the human reviewer's name, review date, inspected record references, result, and any follow-up owner.
| Test | Evidence inspected | Expected result | Reviewer finding |
|---|---|---|---|
| Trace in both directions | Selected sponsor shipment through site evidence; selected disposition back to its originating cohort. | Both paths reach the same device identities and quantities within the selected cohort. | Record matches, missing links, and quantity differences. |
| Retrieve an amendment | Original event, correction reason, replacement or supplementary record, and resulting reconciliation state. | The change is explainable without erasing the original event. | Record whether the correction and its balance effect are traceable. |
| Exercise reviewer handover | Open issue, linked evidence gap, assigned owner, and next action. | Incoming owner locates and explains the issue without undocumented explanations. | Incoming reviewer records the next action or missing context. |
| Reconstruct from an archive | Exported or archived events and retained source references for a selected reconciliation. | Reviewer reconstructs identities, quantities, and unresolved status without relying on a dashboard total. | Record retrieval failures and reconstruction differences. |
Record implementation acceptance separately from decisions resolving individual device discrepancies. A functioning ledger can accurately preserve an open case. The acceptance reviewer records whether these tests passed; the discrepancy owner retains the unresolved case and its next action. Neither decision substitutes for the other.
Frequently asked questions
Q.How can separate partial deliveries from the same batch be reconciled when individual serial identifiers are not used?+
A proposed batch-level register should give each partial shipment and receipt its own event identifier, linked to the shipment reference, batch code, device type, quantity, destination, and actual event date. Match each receipt to its shipment rather than merging deliveries solely because the batch matches. Keep outstanding quantities attached to the relevant shipment until resolved. Use contemporaneous recording to distinguish arrival dates from later entry dates; an internal event identifier identifies the transaction, not an individual device.
Q.How should repeated documented uses of the same reusable device appear without increasing the quantity received?+
As a proposed record design, separate the device inventory register from the use-event log. Link each documented use to the same accountable device or controlled identifier, while leaving its original receipt quantity unchanged. Record its current location and status separately from its accumulated uses. A later return or repair then changes custody or status, not historical receipts. Where individual identification is used, serialized unit tracking can provide the linking concept; this proposal does not make serial numbering a universal requirement.
Q.How should a return be shown when the site has dispatch evidence but the sponsor has not confirmed receipt?+
Use a proposed return-in-transit status linking the site's dispatch event to an expected sponsor receipt. Preserve the dispatch date, quantity, batch or device identifiers, carrier reference, and supporting signature. Keep sponsor receipt unconfirmed until receiving evidence arrives; dispatch alone does not establish arrival. In the combined reconciliation, show the quantity once as being between custodians, not simultaneously received by the sponsor and still on site. Container status tracking is a useful model for separating location evidence from completion status.
Q.What should happen when a shared storeroom login recorded receipt but the receiving person's name is missing?+
Treat the missing attribution as a proposed reconciliation exception, even when the quantity matches. Preserve the original entry and seek supporting evidence, such as a signed delivery record or a documented statement from the actual recipient. Add any substantiated correction with its author, date, reason, and source reference. Do not substitute the account owner or supervisor merely to fill the field. If the person remains unidentified, leave that fact explicit. A data integrity risk assessment can identify how the missing actor limits this particular record and which supported correction is needed.
Q.How should an already-authorised transfer between participating sites appear in the accountability records?+
For an already-authorised transfer, a proposed reconciliation approach is to link the sending site's outbound event, the receiving site's receipt, and the sponsor's transfer reference. Retain both sites' identities, quantities, batch or device identifiers, actual dates, and evidence of the authorisation. Show any interval between dispatch and receipt as transit, with discrepancies assigned for follow-up. Do not describe the movement as a return to the sponsor. The lot genealogy reference preserves the transferred cohort’s original batch relationship while the two custody events retain their own dates.
Q.What should a reviewer do when a scanned return form disagrees with its signed paper original?+
As a proposed review practice, pause acceptance of the disputed return information and compare the scan, paper original, and associated shipment or receipt evidence. Determine whether the problem is an incomplete image, transcription error, wrong document version, or substantive contradiction. Preserve both versions and document the resolution rather than silently replacing the scan. A signature establishes attribution but does not, by itself, settle conflicting quantities. A document control check identifies the retained original and corrected representation; the reconciliation decision records which evidence supports the accepted quantity.
Q.What evidence should accompany a records-custody handover when an investigator's site closes?+
Apply the custody rule in the retention section to the required records; the handover package addresses whether that responsibility can actually be discharged. List the ledger, source attachments and unresolved issues by repository reference. Have the incoming custodian accept the inventory and test retrieval of a selected shipment, its site evidence and the associated amendment. Retain the test result and any inaccessible attachment as an assigned exception. Keep the transfer-notice reference with the signed acceptance rather than assuming notice from a change of storage address. Device custody and records custody have separate transfer evidence.
Q.How should retention be handled when the investigation has ended but the submission-support assessment is unresolved?+
Keep the submission-support assessment open and assign it to the person who can confirm the relevant submission dependency. Apply the required-record scope and later-date rule established in the retention section; do not infer disposal eligibility from study closure alone. The proposed assessment records the submission reference, evidence of continuing or ended support, decision owner and dated conclusion. If an attachment supports more than one submission, inspect each dependency before clearing it. Supplemental sponsor-practice records receive their separately documented retention basis rather than automatically inheriting the legal statement. Preserve the unresolved assessment and its eventual amendment with the archived ledger.
Primary sources
Want to see how Investigational Device Accountability could fit into your own records and workflows? Explore the related V5 pages or talk to our team about what applies to your operation.
