Test Article Characterization
Test Article Characterization is the documented determination of what a batch of test or control article is and which properties define it.

On this page · 12 sections
- 1Test Article Characterization: meaning and record boundaries
- 2The US regulatory map for batch characterization
- 3Build a batch evidence file with separate decisions
- 4Connect receipt, distribution and storage-container identity
- 5Review stability timing and carrier-mixture evidence separately
- 6TAC-1: a CoA does not resolve a container-code mismatch
- 7TAC-2: characterize a marketed control through its labeling
- 8TAC-3: track reserves and stability across two batches
- 9Recover from record mismatches without erasing their history
- 10What FDA inspection coverage adds to the review
- 11Carry article evidence into report and archive review
- 12A final review checklist for the decision record
How does Test Article Characterization apply to your shop floor?
Pick your industry and scale — Ask V5 rewrites the definition in your context, gives a worked example, and shows what V5 does on day one.
01Test Article Characterization: meaning and record boundaries
Test Article Characterization is the documented determination of what a batch of test or control article is and which properties define it.
The practical review question is whether the evidence describes the particular material associated with the study—not merely whether a document bearing an article name exists. A useful review connects the material, batch identifier, supporting records and documented conclusion. This article addresses those record relationships, not synthesis, analytical operations, dose preparation or exposure procedures.
| Record or term | Decision it supports | Boundary |
|---|---|---|
| Characterization record | What defines this batch? | Its title alone does not establish completeness. |
| Supplier certificate of analysis | Which batch results does the supplier report? | Does not alone connect results to the material received. |
| Certificate of conformity | What conformity does the issuer declare? | A declaration is not necessarily batch analytical evidence. |
| Chain-of-custody record | Who transferred or held the material? | Custody history does not establish chemical properties. |
| Reference-standard record | What supports the laboratory reference's assigned use? | Reference suitability is distinct from study-article characterization. |
| Finished-product release record | Was a product batch approved for its intended disposition? | A release decision does not itself establish study-specific characterization. |
These are common record purposes; evidential value depends on content and context. In practical role descriptions, the test article is the material being evaluated; a comparator serves as a control. Consult the current 21 CFR 58.3 definitions for the formal meanings of test article, control article and sponsor in US nonclinical GLP.
For Study Director and QAU orientation, use the US nonclinical GLP overview. For laboratory-reference terminology, see reference standards and reference materials; a laboratory reference used to measure an article is not itself the test or control article.
02The US regulatory map for batch characterization
This article addresses US nonclinical studies subject to Part 58, not every activity undertaken by a pharmaceutical, device, food, supplement or chemical manufacturer. Direct applicability questions to the current Part 58 overview. The map below separates binding duties from inspection guidance, historical interpretation and recommended record-review practice.
Binding regulation. For US nonclinical studies of FDA-regulated test and control articles subject to Part 58, 21 CFR 58.105(a) requires identity, strength, purity, and composition or other appropriately defining characteristics to be determined and documented for each batch. For those US Part 58 studies, the same paragraph requires the sponsor or testing facility to document methods of synthesis, fabrication or derivation. Review here concerns the existence and traceable location of that documentation, not its technical steps.
For US nonclinical studies subject to Part 58, 21 CFR 58.3(n) describes a batch as a specific quantity or lot of a test or control article that has been characterized. The following table is navigation, not a substitute for the detailed review of each topic.
| Provision | Review topic | Detailed treatment |
|---|---|---|
| 58.105(a) | Defining characteristics and marketed controls | Batch evidence; TAC-1 and TAC-2 |
| 58.105(b) | Stability | Stability timing; TAC-3 |
| 58.105(c) | Containers | Receipt, distribution and storage |
| 58.105(d) | Reserves | TAC-3: reserves and retention |
| 58.107 | Handling | Receipt and distribution records |
| 58.113 | Mixtures | Carrier-mixture evidence |
| 58.185, 58.190 and 58.195 | Report and archive review | Report and archive handoff |
FDA inspection guidance. FDA’s GLP compliance program 7348.808 tells investigators what to examine at nonclinical laboratories. On characterization it notes that responsibility for characterization and stability testing may be assumed by the testing facility or the sponsor, and that when the sponsor performs it, the investigator should “verify that the test facility has received documentation that this testing has been conducted.” This describes inspection coverage, not an additional regulation, but it makes the facility’s copy of sponsor documentation a practical review point.
Historical agency interpretation. FDA’s Good Laboratory Practices Questions and Answers, issued in June 1981 with later editorial changes, belongs in this category rather than the binding-regulation category. Use it only where consistent with current Part 58.
Recommended record-review practice. Keep the applicable provision, supporting record location and reviewer conclusion as separate entries. This makes the basis of a decision visible without treating a document’s presence as the decision itself. The detailed sections apply that separation to individual evidence relationships.
03Build a batch evidence file with separate decisions
A useful evidence model separates the study-facing article identity and role—test or control—from the particular material batch. Use an article record for the former, a batch record for the latter, and separately indexed evidence records for supporting documents. A study decision references those records rather than replacing them; the same evidence may support different conclusions for different study contexts.
These suggested fields and relationships suit paper or electronic records. They are not a mandated database, software capability or automated approval mechanism. The following inventory is a practical index, not a prescribed regulatory form; status prompts guide review rather than assert completion.
| Question | Evidence pointer | Matching key | Review status |
|---|---|---|---|
| Defining characteristics? | Characterization report | Article/batch | Assess coverage |
| Source-method documentation? | Sponsor/facility record | Article/batch applicability | Confirm linkage |
| Stability? | Stability record | Batch/conditions | Assess timing |
| Container identification? | Label record | Container/batch | Reconcile identifiers |
| Receipt and distribution? | Accountability record | Batch/transaction | Trace movements |
| Mixture evidence relevant? | Mixture report | Batch/mixture/study | Assess applicability |
| Reserve or archive linkage? | Location/retention index | Batch/study | Confirm retrieval |
A certificate of analysis can contain batch-specific results, while a certificate of conformity may address a different declaration. Evaluate actual content, issuing organization, batch association and document version rather than accepting either title alone.
Distinguish the person or organization providing a record from the person making the study-facing decision. Record the conclusion, supporting references, unresolved questions and responsible reviewer. Assign review accountability through the study’s arrangements rather than assuming a universal approval chain.
Article
Identifies the material and its study-facing role.
- article_id
- article_name
- study_code
- article_role
Batch
Connects a particular batch to its physical container.
- batch_id
- article_id
- supplier_lot
- container_id
Evidence record
Locates supporting information and its document version.
- evidence_id
- batch_id
- evidence_type
- document_version
Study decision
Separates the human conclusion from supporting evidence.
- study_id
- evidence_ids
- decision_basis
- decided_by
Retention link
Connects a reserve to location and retention review.
- batch_id
- reserve_id
- archive_location
- retention_basis
04Connect receipt, distribution and storage-container identity
For US nonclinical studies of FDA-regulated test and control articles subject to Part 58, 21 CFR 58.105(c) requires each storage container to identify the article by name, chemical abstract number or code number, together with the batch number and expiration date, if any.
For US nonclinical studies of FDA-regulated test and control articles subject to Part 58, 21 CFR 58.105(c) also requires labeling with storage conditions where appropriate to maintain the article’s identity, strength, purity and composition.
For US nonclinical studies of FDA-regulated test and control articles subject to Part 58, 21 CFR 58.105(c) requires storage containers to be assigned to a particular test article for the study’s duration.
For US nonclinical inspections involving FDA-regulated test and control articles, FDA’s GLP inspection program directs attention to procedures for receipt and distribution documentation, identification and storage. This is inspection coverage, not additional law. Consult current 21 CFR 58.107 for handling requirements.
As a practical review approach, use chain-of-custody records to connect receipt, transfers, destinations and container identifiers. Start with the received container, then follow its identifier through each recorded movement to the study destination. Compare the article and batch identifiers across those records rather than relying on a destination name alone. This linkage helps a reviewer distinguish a documented transfer from an unexplained change in identity; it does not prescribe a universal form.
05Review stability timing and carrier-mixture evidence separately
For US nonclinical studies of FDA-regulated test and control articles subject to Part 58, 21 CFR 58.105(b) assigns stability determination to the testing facility or sponsor; 58.105(b)(1)–(2) permits determination before study initiation or concurrently under written SOPs providing for periodic analysis of each batch.
For US nonclinical studies subject to Part 58 involving FDA-regulated test or control articles mixed with carriers, 21 CFR 58.113(a)(1) requires testing to determine mixture uniformity and, periodically, article concentration in the mixture.
For these US nonclinical carrier-mixture studies subject to Part 58, 21 CFR 58.113(a)(2) requires determination of article stability in the mixture as required by study conditions; 58.113(a)(2)(i)–(ii) permits determination before initiation or concurrently under written SOPs providing for periodic analysis of the articles in the mixture.
For US nonclinical studies subject to Part 58 involving FDA-regulated test or control article carrier mixtures, 21 CFR 58.113(c) requires a component’s expiration date, when present, to appear clearly on the container; where multiple components have expiration dates, the earliest date must appear.
As a record-review practice, keep original-article and carrier-mixture conclusions separate. An original-article stability assessment does not, by itself, answer whether evidence addresses that article in a particular mixture. Review each evidence set against these questions:
- Does the record identify the relevant batch and material form, including the carrier mixture where applicable?
- Do the stated conditions and applicable period match the circumstances being reviewed?
- Are analytical dates, the stability-assessment date and any expiration date separately identifiable?
- For concurrent determination, which SOP and completed periodic-analysis records support the assessment at the review date?
Record the reviewer’s conclusion and any remaining evidence gap rather than treating a dated result as a complete stability decision. For related terminology, see retest and expiry dating; keep that distinction separate from the study-specific stability assessment.
- Define the roleIdentify the study article or comparator and study context.
- Match the batchConnect container identifiers, receipt records and supplier evidence.
- Review defining propertiesLocate the records describing this particular article batch.
- Review applicable stabilityIdentify timing, supporting records and relevant mixture evidence.
- Resolve evidence gapsDocument discrepancies, additional evidence and remaining uncertainty.
- Record the decisionIdentify the reviewer, conclusion and supporting record references.
- Preserve the linksConnect reserves, report references, archive locations and retention decisions.
06TAC-1: a CoA does not resolve a container-code mismatch
All worked records in TAC-1, TAC-2 and TAC-3 are fictional. The cases use Compound TX-14 batch B03 as the test article and commercial control article C as the comparator. Here, assume the B03 supplier certificate of analysis (CoA) includes identity and purity result fields, their reporting basis or units, and a stability-assessment date reference. The observed container code differs from the protocol article code.
Keep results, units and dates as source-record fields; do not substitute illustrative values or acceptance limits. The table separates source-owner confirmation from the designated reviewer's decision about whether the records establish the material relationship.
| Field | Evidence | Source | Who decides |
|---|---|---|---|
| Protocol article code | Code exactly as recorded | Applicable protocol | Protocol owner confirms meaning; reviewer assesses linkage |
| Observed container code | Code as observed, without normalization | Label image and receipt record | Receiving personnel confirm observation; reviewer assesses discrepancy |
| Batch number | B03 across linked records | CoA, label, receipt record | Reviewer assesses batch linkage |
| Identity result | Original result and reporting basis | Supplier CoA | Supplier clarifies entry; reviewer assesses relevance |
| Purity result and unit | Original value, unit and basis | Supplier CoA | Supplier clarifies entry; reviewer assesses relevance |
| Stability-assessment date and linked record | Original date reference and supporting record | CoA and referenced assessment | Source owner confirms reference; reviewer assesses applicability |
| Documented code reconciliation | Explanation with supporting cross-reference | Discrepancy record and source-owner response | Designated reviewer accepts or rejects explanation |
| Study-facing use decision | Status, rationale and decision attribution | Linked decision record | Locally designated decision-maker records disposition |
Matching B03 text on the CoA does not itself explain why the container carries a different code. A documented alias, a transcription error and unresolved material identity are alternative explanations—not findings. Request the evidence that distinguishes them: an attributable code cross-reference, a supported correction identifying the erroneous entry, or additional receipt and supplier records connecting the container to the characterized batch.
Use unresolved-identity status until the reviewer records a supported reconciliation decision before use in this example. A source owner's explanation informs that decision; it does not replace it. This focused exception-based review addresses the identifier conflict rather than treating populated analytical fields as closure.
Retain the original discrepancy and the evidence supporting any subsequent decision. Merely renaming a file does not explain the material relationship. These are locally assigned review roles, not a universal release authority for the Study Director, QAU or sponsor.
07TAC-2: characterize a marketed control through its labeling
For US nonclinical studies subject to Part 58 that use marketed products as control articles, 21 CFR 58.105(a) states that those products will be characterized by their labeling.
Assume commercial control article C is a marketed product used as the study comparator. A practical file would contain:
- A legible label copy associated with the product received.
- The lot identifier and expiry information shown.
- Links to the receipt record and relevant container records.
These are practical evidence-organization choices, not a separate statutory document list. The review question is whether the labeling describes the actual control article received, rather than merely a product with the same commercial name.
The file remains inconclusive if a generic image cannot be associated with the received product, the lot is unreadable, or a transferred container lacks a documented relationship to the original. These are unresolved evidence links—not automatic legal disqualification or an automatic requirement for additional testing. A reviewer can document the missing connection, seek corroborating receipt or transfer records, and record whether the connection was established. A data integrity risk assessment can help organize that assessment without substituting for the missing evidence.
For the remaining study-use questions, refer to the earlier stability, storage and carrier-mixture sections; the labeling route does not settle those decisions.
08TAC-3: track reserves and stability across two batches
For US nonclinical studies of FDA-regulated test and control articles subject to Part 58 that last more than four weeks, 21 CFR 58.105(d) requires reserve samples from each batch of test and control articles.
Assume the study lasts more than four weeks and uses Compound TX-14 batch B03 and a second test-article batch, B04. The table separates their reserve and stability links; a study-level reserve entry alone does not demonstrate coverage of both batches.
| Batch | Reserve identifier and location | Stability route | Supporting record | Retention basis |
|---|---|---|---|---|
| TX-14 B03 | RES-B03; reserve store, position A | Before study initiation | B03 stability report; reserve inventory entry | 58.195 applicability and trigger review pending |
| TX-14 B04 | RES-B04; reserve store, position B | Concurrent, SOP-based | Applicable SOP; B04 periodic-analysis records; reserve inventory entry | 58.195 applicability and trigger review pending |
Apply the stability routes covered above to each row. For B03, check that the report identifies that batch and supports the stated timing. For B04, connect the applicable SOP to its periodic-analysis records rather than recording only that an SOP exists. Do not infer that B03 evidence also describes B04. The reviewer records a separate conclusion for each batch.
Consult current 21 CFR 58.195 for the applicable retention period and scope. Record the identified basis and triggering event before assigning a disposition date; neither expiration nor study completion should substitute for that review. See reserve and retain samples for related terminology.
FDA’s historical GLP questions and answers addressed whether reserve samples may be analyzed when the Study Director or QAU requires it, answering: “Yes, but sufficient reserve sample should be retained so that the sample is not exhausted.” Treat this as historical interpretation, not a new requirement; a practical file records the withdrawal, the requester and the remaining quantity.
09Recover from record mismatches without erasing their history
A practical record interface connects supplier documents, receipt logs, study records, analytical records and archive entries through article identity, batch identifier, study identifier, evidence identifier and document version. These matching keys describe information relationships, not software features. Preserve the relationship between the document received and the evidence used for a decision.
| Failure | Why review remains open | Recovery evidence | Decision record |
|---|---|---|---|
| Corrected CoA without version relationship | Superseded content unclear | Linked versions and supplier explanation | Accepted version; impact on prior conclusions |
| Conflicting batch aliases | Material linkage uncertain | Attributable alias reconciliation | Accepted mapping and rationale |
| Stability evidence for different material form | Applicability unestablished | Form-specific evidence or justified applicability assessment | Supported scope and remaining limitations |
| Missing transfer destination | Receiving location unknown | Dispatch and receiving records | Reconciled destination or unresolved gap |
| Equipment-status issue affecting a reported result | Result confidence needs assessment | Equipment history linked to analytical record | Affected results and reasoned disposition |
Use an audit trail to preserve what changed, who changed it, when and why; no particular technical implementation is implied. Correcting a record and assessing its impact are separate tasks. Document whether the correction changes an earlier conclusion, identify affected decisions and assign follow-up.
Where characterization evidence depends on equipment records, review the relevant calibration status. A later finding may prompt an as-found and as-left calibration review to assess confidence in earlier analytical evidence. Focus on the affected equipment, period and results; a status issue does not automatically invalidate every result. These are suggested recovery approaches, not universal invalidation rules.
10What FDA inspection coverage adds to the review
For US nonclinical inspections involving FDA-regulated test and control articles, FDA's GLP inspection program examines documentation of sample transfer from collection to the analytical laboratory. The inspection perspective connects the characterization result to the sample's documented journey.
For completed US nonclinical studies involving FDA-regulated test and control articles, FDA's GLP inspection program directs inspectors to verify documentation of final article reconciliation. For review preparation, make the completed reconciliation readily retrievable rather than leaving it disconnected from the study file.
As a practical organizing approach, use an inspection record to connect an observed issue, the affected evidence, the response owner, the response and its review status. For a missing transfer entry, that trail would identify the gap and link the response to supporting records; merely marking the finding closed would not explain the resolution. Keep the examination record, the response and any study-facing decision distinguishable. Use QA audit records for audit terminology, without treating an audit conclusion as approval to use an article.
11Carry article evidence into report and archive review
For US nonclinical studies subject to Part 58, consult current 21 CFR 58.185 for final-report provisions and 21 CFR 58.190 for storage and retrieval provisions. Carry forward the retention review associated with 21 CFR 58.195, rather than assigning a generic retention duration at handoff.
Archive controls in 21 CFR 58.190 shape how characterization evidence stays usable. The section requires archives “for orderly storage and expedient retrieval” of raw data, documentation, protocols, specimens and reports; an individual identified as responsible for the archives; entry limited to authorized personnel; and that material retained or referred to in the archives “shall be indexed to permit expedient retrieval.” Raw data and specimens may be held elsewhere if the archives specifically reference those locations. For characterization, that means the sponsor-supplied report, the CoA, label copies and reserve-sample locations should each be findable from the study index, including any held at a sponsor or commercial repository.
Use this practical handoff checklist to connect the report to its supporting evidence:
- Reconcile report article and batch identifiers with the evidence index and relevant lot pedigree.
- Identify current and superseded documents so reviewers can distinguish the decision basis from earlier versions.
- Preserve the evidence and rationale supporting resolved discrepancies.
- Confirm retrieval locations for referenced records and retained material.
- Carry unresolved matters forward explicitly, with an identified follow-up owner.
Keep evidence location separate from retention and disposition decisions. A reserve-location entry answers where material is held; an archived CoA preserves analytical evidence; a documented disposition decision records a human conclusion and its basis. Link these records without collapsing them into a single completion flag. Finding a record does not itself establish whether its associated material may be discarded.
12A final review checklist for the decision record
Use these practical prompts to close the review, referring to the earlier sections for the underlying distinctions:
- Is the article’s role clear: test article or control?
- Are the physical container and batch connected to the evidence?
- Are defining-characteristic records identifiable and retrievable?
- Is the applicable stability route documented?
- Are mixture questions addressed where relevant?
- Are discrepancies resolved or explicitly open, with the supporting rationale linked?
- Are reserve-sample and archive links traceable?
- Is the decision attributable to a named person, with its basis recorded?
Suggested outcomes are: evidence supports the documented decision; additional evidence is needed; or an unresolved discrepancy remains. Avoid a generic complete status that hides the reason. Link any outstanding deviation and relevant audit trail history to the decision.
These prompts recommend a review sequence, not a prescribed regulatory workflow or automated release. The FAQs address narrow applications and exceptions.
Frequently asked questions
Q.Can a supplier's certificate of analysis establish that an article is ready for study use on its own?+
A supplier CoA is evidence for review, not a standalone readiness decision. For Compound TX-14 batch B03, a fictional example, the reviewer would typically connect the certificate to the received container, study identifier, applicable stability information and storage history. An acceptable analytical result does not resolve a missing identity link. Record the human decision and its basis separately from the certificate. The broader US nonclinical GLP framework provides context for organizing that review.
Q.Can a container-code discrepancy be closed when the analytical results are unchanged but the identity link remains unexplained?+
No—not as a defensible record-review decision. Unchanged analytical results establish nothing about whether the certificate belongs to the container under review. Typically, the reviewer keeps the identity question open, obtains attributable reconciliation evidence and documents the decision before study use. Useful evidence might include the original dispatch record and an authorized explanation connecting the identifiers. A deviation record can organize the investigation, but closing that record does not itself establish the missing connection.
Q.What should a reviewer do when commercial control article C has been transferred out of its original labeled container?+
Preserve the original label copy and connect its lot and expiry information to the receiving container through an attributable transfer record. Then review the receiving container against the label particulars explained in the receipt, distribution and storage section, including the qualifiers “expiration date, if any” and storage conditions where appropriate. If the transfer record is missing, keep the control article’s identity link open and record what corroborating evidence was sought; do not infer the link from a matching commercial name.
Q.What should a reviewer check if a concurrent stability analysis is overdue when an interim report is prepared?+
Identify the SOP that set the periodic schedule, the analysis that is overdue and the period of article use it was meant to cover. Record the gap in the interim review rather than describing stability as supported, and link the eventual result back to that period when it arrives. Whether material used during the gap remains acceptable is a documented human decision with its rationale, not an automatic consequence of the later result.
Q.How does the reserve-sample threshold apply to a study lasting exactly four weeks?+
For test and control articles in US nonclinical GLP studies, 21 CFR 58.105(d) specifies studies of more than four weeks’ duration. A study lasting exactly four weeks does not cross that particular threshold. As a review practice, document the duration basis rather than relying on a rounded study description. Also check the protocol and applicable procedures for additional retention commitments. If the study is extended, reassess the reserve-sample decision against its revised duration.
Q.Can a characterization reserve be analyzed without exhausting the retained sample?+
FDA’s 1981 GLP questions and answers answered that reserve analysis requested by the Study Director or QAU is permitted, “but sufficient reserve sample should be retained so that the sample is not exhausted.” As a practical safeguard, record the request, the quantity withdrawn and the quantity remaining, and check that the withdrawal does not leave the batch without a usable reserve for the remaining retention period.
Q.Who should hold the mixture records when a contract laboratory prepares carrier mixtures for a sponsor?+
Part 58 does not answer this with a universal owner; the study arrangements should state who generates and who retains mixture analyses. For the review, the testing facility’s study file should either contain the mixture records or reference their specific archive location, consistent with the archive indexing discussed in the report and archive section. A reviewer who cannot locate a mixture result from the study index should treat that as an open retrieval gap.
Q.How should a corrected CoA received after report completion be connected to the earlier record and its audit trail?+
As a record-review practice, retain the earlier CoA and attach the corrected version with its receipt date, issuer, explanation of the change and explicit predecessor link. Identify which characterization conclusions or report statements used the earlier version. Record a human assessment of the correction’s significance and the resulting follow-up decision; do not silently replace the certificate. The audit trail should make the sequence understandable without suggesting that the corrected information was available when the original decision was made.
Primary sources
- 21 CFR Part 58 current text incl. 58.3, 58.105, 58.107, 58.113, 58.120, 58.130, 58.185, 58.190, 58.195
- FDA Compliance Program 7348.808 Good Laboratory Practice (Nonclinical Laboratories), test and control article inspection coverage
- FDA Good Laboratory Practices Questions and Answers (June 1981; editorial changes 1999 and 2007) - historical agency interpretation
Want to see how Test Article Characterization could fit into your own records and workflows? Explore the related V5 pages or talk to our team about what applies to your operation.