V5 Ultimate
Ultimate
PricingResourcesCompany
English (original)العربيةDeutschΕλληνικάEspañolFrançaisItalianoעברית日本語한국어NederlandsPolskiPortuguêsSvenska
Talk to us Log in Start free trial
Food & Beverage
  • Bakery & Confectionery
  • Food Processing
  • Ingredients & Dry Mixes
  • Sausage & Meat Products
  • Produce Packing
  • Pet Food & Pet Supplements
  • Dairy & Chilled Foods
  • Beverages & Liquid Manufacturing
  • Infant Formula
Pharma & Life Sciences
  • Radiopharmaceuticals
  • Pharmaceutical
  • Medical Devices
  • Veterinary Pharmaceuticals
  • Blood & Tissue
  • Diagnostics & IVD Kits
  • Reference Materials & Standards
  • OTC Topical Creams & Gels
Supplements & Personal Care
  • Dietary Supplements
  • Cosmetics & Personal Care
  • Cannabis & Hemp Manufacturing
  • Fragrances & Perfumery
  • Soaps & Personal Hygiene
  • Botanical Extracts & Essential Oils
Chemicals & Materials
  • Plastics & Resins
  • Agricultural Chemicals
  • Specialty & Industrial Chemicals
  • Printing Inks, Pigments & Construction Chemicals
  • Lubricants & Metalworking Fluids
  • Coatings, Adhesives & Sealants
Other Manufacturing
  • Consumer Products
  • Electronics & Electrical Assembly
  • Textiles & Nonwoven
  • Contract Manufacturing & Co-Packing
  • Packaging & Food-Contact Materials
  • Regulated Warehousing & Distribution
Explore all industries
  • Warehouse & TraceabilityReceive, store, pick and trace
  • Production & PlanningPlan jobs and guide production
  • Quality & LaboratoryTest, investigate and review
  • Documents & TrainingControl procedures and qualifications
  • Equipment & PerformanceMaintain assets and measure losses
  • Orders & IntegrationsConnect customers, suppliers and systems
  • Outputs & InsightsReports, KPIs and label design
Why V5? Product & Features
Why V5?Product & Features
  • Warehouse & TraceabilityReceive, store, pick and trace
  • Production & PlanningPlan jobs and guide production
  • Quality & LaboratoryTest, investigate and review
  • Documents & TrainingControl procedures and qualifications
  • Equipment & PerformanceMaintain assets and measure losses
  • Orders & IntegrationsConnect customers, suppliers and systems
  • Outputs & InsightsReports, KPIs and label design
Explore all industries
    • Bakery & Confectionery
    • Food Processing
    • Ingredients & Dry Mixes
    • Sausage & Meat Products
    • Produce Packing
    • Pet Food & Pet Supplements
    • Dairy & Chilled Foods
    • Beverages & Liquid Manufacturing
    • Infant Formula
    • Radiopharmaceuticals
    • Pharmaceutical
    • Medical Devices
    • Veterinary Pharmaceuticals
    • Blood & Tissue
    • Diagnostics & IVD Kits
    • Reference Materials & Standards
    • OTC Topical Creams & Gels
    • Dietary Supplements
    • Cosmetics & Personal Care
    • Cannabis & Hemp Manufacturing
    • Fragrances & Perfumery
    • Soaps & Personal Hygiene
    • Botanical Extracts & Essential Oils
    • Plastics & Resins
    • Agricultural Chemicals
    • Specialty & Industrial Chemicals
    • Printing Inks, Pigments & Construction Chemicals
    • Lubricants & Metalworking Fluids
    • Coatings, Adhesives & Sealants
    • Consumer Products
    • Electronics & Electrical Assembly
    • Textiles & Nonwoven
    • Contract Manufacturing & Co-Packing
    • Packaging & Food-Contact Materials
    • Regulated Warehousing & Distribution
PricingResourcesCompany
Start free trial Log in Talk to us
HomeGlossaryUnit of Use DI
Quality · The complete guide

Unit of Use DI

In short

Follow a US FDA GUDID multipack from its package identifiers to an individual patient-use record without losing lot or quantity context.

4,098 words · ~19 min read
Unit of Use DI: a gowned, gloved stockroom worker scans a 100-tube box label while holding one unlabeled single-use tube from inside
A Unit of Use DI is a virtual identifier for the single device inside a multi-device base package when the device itself carries no UDI label.
On this page
  1. 01What Unit of Use DI identifies
  2. 02Does the package configuration fit?
  3. 03Primary, Unit of Use, Package and Direct Marking DI
  4. 04FDA's example: a box of tubes inside a case
  5. 05US FDA scope: guidance, regulation and local controls
  6. 06Worked receipt: three cases of fictitious lancets
  7. 07From an opened box to a patient-use record
  8. 08Record fields that preserve the receipt-to-use chain
  9. 09Integrations and recovery when a link is missing
  10. 10Failure modes that break individual-use traceability
  11. 11A qualified review before relying on the record
On this page · 11 sections
  1. 1What Unit of Use DI identifies
  2. 2Does the package configuration fit?
  3. 3Primary, Unit of Use, Package and Direct Marking DI
  4. 4FDA's example: a box of tubes inside a case
  5. 5US FDA scope: guidance, regulation and local controls
  6. 6Worked receipt: three cases of fictitious lancets
  7. 7From an opened box to a patient-use record
  8. 8Record fields that preserve the receipt-to-use chain
  9. 9Integrations and recovery when a link is missing
  10. 10Failure modes that break individual-use traceability
  11. 11A qualified review before relying on the record
AI · Explain it for MY operation

How does Unit of Use DI apply to your shop floor?

Pick your industry and scale — Ask V5 rewrites the definition in your context, gives a worked example, and shows what V5 does on day one.

Your scale

01What Unit of Use DI identifies

Unit of Use DI is, in US FDA GUDID, a virtual identifier assigned to an individual medical device when a UDI is not labeled on that device at its unit of use. The virtual identifier is not printed on the individual device. For US medical devices, FDA’s GUDID guidance connects this identifier to associating an individual device’s use with a patient when the base package contains multiple devices.

FDA’s GUDID guidance, Section III.A.(2) defines Unit of Use DI as: “A virtual identifier assigned to an individual medical device when a UDI is not labeled on the individual device at the level of its unit of use. Its purpose is to associate the use of a device to/on a patient when a base package contains more than one device.”

The operational focus here is the handoff from package receipt to individual use: receive the package, maintain a controlled identifier mapping, open the base package and record a device’s use. The patient-use record described here is a proposed local traceability design for manufacturers and downstream users, not an FDA-mandated clinical workflow. Its practical aim is to keep the package received connected to the device used, without treating those events as interchangeable. In this proposed design, a qualified person approves record changes.

All DIs, lot numbers, codes and quantities in the worked examples are fictitious teaching values, not production-ready identifiers. Broader terminology belongs in the UDI overview; this article concentrates on the unit-of-use mapping and the records that preserve it.

02Does the package configuration fit?

For US FDA medical-device GUDID terminology, start the configuration review with the individual device at its actual unit of use—not whichever package happens to be scanned at receipt. This keeps the decision focused on the device used on a patient rather than the warehouse handling unit.

For US medical devices, FDA’s GUDID guidance, Section III.A.(2), Unit of Use DI, describes an individual device without a UDI labeled at its unit of use, where the base package contains more than one device. These are the two configuration questions to resolve before proposing a local mapping.

First, inspect the individual-device labeling. For US medical devices, Appendix A, Example 2 (Figure A2) in FDA’s GUDID guidance illustrates a catheter that carries its own Primary DI with Device Count = 1 inside two package levels. Do not force that configuration into the virtual-identifier scenario merely because receiving staff scan an outer package.

Second, establish the base-package device count. Under this proposed local decision aid, a single-device package, uncertain count or ambiguous unit-of-use boundary goes to qualified review. Record the unresolved question rather than selecting a convenient identifier. Keep this configuration assessment separate from the GUDID submission workflow.

The successful branch below means the configuration matches the guidance description; it is not a blanket legal requirement to assign an identifier.

Individual device labeled with UDI at actual unit of use? ├─ Yes → Outside this virtual-identifier scenario ├─ Uncertain → Qualified review └─ No → Base package contains more than one device? ├─ No or uncertain → Qualified review └─ Yes → Configuration matches guidance description → Qualified person reviews and approves local mapping Ambiguous unit-of-use boundary at either question → Qualified review

US FDA GUDID configuration decision
  1. 1
    Identify the individual deviceStart at its unit of use, not the receipt package.
  2. 2
    Individual device labeled with UDI?Yes → labeled-device route. No → inspect the base package.
  3. 3
    Labeled-device routeOutside this virtual-identifier scenario.
  4. 4
    Base package holds more than one device?Yes → check the assigned Unit of Use DI. No or unclear → qualified review.
  5. 5
    Check the assigned relationshipConfirm the Unit of Use DI, Primary DI and device count.
  6. 6
    Resolve uncertaintyKeep missing mappings visible; do not invent an identifier.
  7. 7
    Approve the operational mappingA qualified person approves record changes.
A configuration check based on the guidance definition, followed by local review—not a determination of labeling-exception eligibility.

03Primary, Unit of Use, Package and Direct Marking DI

For US medical devices, FDA GUDID guidance, Section III.A.(2), identifier roles distinguishes the identifiers below. The receipt-to-use column proposes operational checks, not additional FDA requirements. Select a field by its documented role and package relationship, rather than treating every DI as interchangeable.

IdentifierRole in US FDA GUDIDPhysical referenceReceipt-to-use relevance
Primary DIFor US devices, identifies the lowest package level containing a full UDI; the guidance calls this the base package.Base package.Keep the base-package identity attached to the stock unit.
Unit of Use DISee the definition above.Individual-use reference, as covered above.Keep the approved association available when recording use.
Package DIFor US devices, describes a configuration containing multiple base packages, excluding shipping containers.Containing package configuration.Preserve the relationship to the contained package before converting stock quantities.
Direct Marking DIFor US devices subject to direct-marking requirements, identifies the permanent mark directly on the device; it can match or differ from the Primary DI.Device itself.Keep the marked identifier's role explicit; do not assume it is a separate package level.

For US medical devices, the guidance limits Direct Marking DI applicability to devices subject to direct-marking requirements under 21 CFR 801.45; this comparison does not determine that applicability.

Give each count its package relationship

For US medical devices, FDA GUDID guidance, Section III.A.(2), package information describes Device Count as the number of medical devices in the base package, and Quantity per Package as the number of packages contained within the particular configuration. Quantity per Package is therefore not an unqualified count of individual devices.

Read the tube illustration in the next section with those units attached: Device Count concerns tubes within the base box; Quantity per Package concerns boxes within the case. Operationally, retain both the containing package and the referenced contained package beside the quantity. A conversion is interpretable only when the relationship and units are explicit. Do not infer those units from an identifier's appearance. Keep issuing-agency and trade-item numbering background separate in GTIN terminology.

04FDA's example: a box of tubes inside a case

FDA’s US medical-device GUDID illustration in Appendix A, Example 1 connects a base package of blood collection tubes to a larger case. The DIs in this guidance example are fictitious. FDA describes the base package as follows:

"Box of 100 single use blood collection tubes with the Primary DI 20001 and Device Count = 100."

For the individual tubes in this US medical-device example, the FDA guidance explains:

"Note that the tubes themselves do not have the DI on them as they fall under the general exception for individual single use device under 801.30(a)(3). Each tube however, gets a virtual Unit of Use DI assigned, and in this case, 10001."

Keep that exception explanation tied to FDA’s tube illustration; it is not a determination that another multipack or a lancet configuration qualifies. The same US FDA guidance illustration describes the outer package:

"Case of 8 boxes (800 total), with Package DI 30001 (contains 8 of Primary DI 20001), Quantity per Package = 8."

The unit conversion is explicit: 8 boxes per case × 100 tubes per box = 800 tubes per case. The case quantity counts boxes, while the base-package device count counts tubes. Keeping those units attached to the numbers prevents a package quantity from being mistaken for a device quantity.

Operationally, a case receipt and an individual tube-use event need different quantity contexts, even when connected through this hierarchy. Receiving the case establishes stock in package units; it does not establish that the tubes were used on patients. A local record can retain the package relationship while recording use separately. This is a practical application of production context tagging: preserve what the event concerns, not merely the identifier value. The separate lancet example below applies that recordkeeping approach to a hypothetical receipt-to-use chain, without borrowing the tube example’s exception conclusion.

05US FDA scope: guidance, regulation and local controls

Keep three categories separate when applying Unit of Use DI terminology to a receipt-to-use process:

  • Official guidance: the US FDA GUDID guidance provides the descriptions and package examples discussed here.
  • Applicable regulations: US medical-device regulations govern the legal questions; a guidance example is not a product-specific applicability determination.
  • Local controls: the decision diagram and receipt-to-use record fields are proposed operational tools, not regulations. Evaluate them against the actual packaging, labeling and handling process before adoption.

For US medical devices, 21 CFR 830.310, item (10) lists the type of production identifiers that appear on the device label. Do not turn that statement into a requirement for the proposed patient-use record: the local record design is a separate operational decision.

For US medical devices, check the current text of 21 CFR 801.30 for exception scope and 21 CFR 801.3 for applicable definitions. Do not infer the fictional lancet configuration’s legal eligibility from the guidance’s blood-tube example.

EU and other markets have their own rules; this article addresses US FDA medical-device terminology only. For product-scope questions, see medical-device classification. For the fixed and variable parts of the identifier itself, see DI versus PI.

The fictional lancet exercise assumes an appropriately established product and labeling configuration. It tests record logic; it does not authorize unlabeled devices, a packaging change, a clinical technique or a sterility claim.

06Worked receipt: three cases of fictitious lancets

Assume a fictitious sterile single-use lancet with this configuration: the base box has Primary DI 20417 and Device Count 50; its assigned Unit of Use DI is 10417; and a fixed case configuration has Package DI 30417 and contains 10 boxes of Primary DI 20417. Lot L-5530 appears on the box label. The individual lancet has no labeled UDI; Unit of Use DI 10417 is virtual, not printed on it. Assume receipt of 3 intact cases, all with this configuration and lot. Every identifier, lot and quantity in this example is fictional; the short DIs are not valid GTIN examples.

Record the physical receipt as 3 cases against Package DI 30417. Keep the documented unit-of-measure conversion available for later movements rather than posting additional receipts for the contents:

  • 3 cases × 10 boxes per case = 30 boxes.
  • 30 boxes × 50 lancets per box = 1,500 lancets.

Here, 3 cases is the recorded receipt quantity; 1,500 lancets is the calculated equivalent device quantity. They describe the same stock at different levels, not separate additions. Neither quantity represents a patient-use event. The conversion establishes how many lancets the assumed contents represent, not how many have been opened, issued or used.

Next, open one case and separate its boxes, leaving every box unopened. In the proposed perpetual inventory record, replace that case balance with its box contents:

  • (2 cases × 10 boxes per case) + 10 separated boxes = 30 boxes.
  • 30 boxes × 50 lancets per box = 1,500 lancets.

Do not retain all 3 original cases as available stock while also adding the 10 separated boxes. That would count the opened case twice. This unpacking movement changes the stock presentation, not the total equivalent device quantity.

For transaction provenance, retain the original scanned identifier, its interpreted role as Package DI, the case-to-box relationship used and the approved mapping version. A case scan is not a scan of Unit of Use DI 10417: the latter is reached through the documented relationship, not observed on the individual lancet.

Hypothetical package hierarchy

Case — Package DI 30417 ├─ Receipt record: 3 cases ↓ 10 boxes per case Box — Primary DI 20417; lot L-5530 ↓ 50 lancets per box Individual lancet — virtual Unit of Use DI 10417 └─ Later patient-use record: Unit of Use DI 10417 + box-label lot L-5530 The patient-use branch shows the intended later record relationship, not a use established by this receipt.

Fictitious lancet hierarchy: case → box → unit

Case → box

Ten base boxes per case.

  • package_di: 30417
  • contains_di: 20417
  • quantity_per_package: 10

Box → unit

Fifty lancets per base box.

  • primary_di: 20417
  • device_count: 50
  • unit_of_use_di: 10417

Individual lancet

Virtual identifier; not printed on the lancet.

  • unit_of_use_di: 10417

Receipt

Three cases, equivalent to thirty boxes.

  • receipt_id
  • package_di: 30417
  • receipt_quantity_cases: 3

Patient-use event

One lancet linked to its source box.

  • unit_of_use_di: 10417
  • lot_number: L-5530
  • use_quantity: 1 lancet
  • source_box_ref
  • patient_encounter_ref
Package relationships connect receipt to individual use; the source-box record supplies the observed lot.

07From an opened box to a patient-use record

At the point of use, select one box from the separated stock in the fictional lancet example. Capture Primary DI 20417 and lot L-5530 from its box label, then resolve Unit of Use DI 10417 through the relationship approved at configuration. Keep these as separate evidence steps: label capture establishes what was observed on that box; mapping resolution establishes which virtual identifier applies. Do not describe the resolved identifier as a value scanned from the lancet.

For one fictional use event, record Unit of Use DI 10417, lot L-5530, use quantity 1 lancet, an appropriate patient or encounter reference, the event time and the source-box reference. These are proposed local fields, not a claim that GUDID stores patient-use events. The source-box reference connects this documented use to the particular box selected, rather than merely to another box carrying the same product identifier. This is a practical application of discrete consumption: record the individual use, not just the package movement.

Assuming no other use, loss, discard or movement occurred, reconcile the original receipt after this event:

  • 2 intact cases × 10 boxes per case × 50 lancets per box = 1,000 lancets.
  • 9 closed boxes × 50 lancets per box = 450 lancets.
  • 49 lancets remain in the opened box.
  • Remaining stock: 1,000 + 450 + 49 = 1,499 lancets, with 1 recorded as used.

Opening a box does not establish that every device inside was used. Preserve opening, use and any later waste or return as distinct event types. An inventory conversion alone is not a basis for adjusting a patient record; it describes package handling, not observed patient exposure.

Keep a controlled association with the source box while its contents are in use. A local container reference linked to retained label information can support lot genealogy at the storage location. That reference is not a replacement label and does not make the virtual DI physically marked on the lancet. Sterility and handling remain subject to the product’s established procedures.

08Record fields that preserve the receipt-to-use chain

The following proposed local schema is not a set of official GUDID submission-field names. All identifiers, lot numbers and quantities belong to the fictitious lancet example. Transaction records carry event_type, event_time, quantity and quantity_uom; mapping_version identifies the package relationship used.

StageIdentifier and roleQuantity and unitLot sourceLink to prior recordReview evidence
Configuration approvalprimary_di=20417; unit_of_use_di=10417; package_di=30417; contains_di=20417device_count=50 lancets/box; quantity_per_package=10 boxes/caseNo transaction lotmapping_versionapproved_by; relationship evidence
Case receiptpackage_di=30417 identifies received configurationquantity=3; quantity_uom=caselot_number=L-5530; linked box-label evidencereceipt_id; mapping_versionReceipt check; source_label_ref
Case-to-box movementprimary_di=20417 identifies box configuration10 boxes per case movedL-5530, linked label recordreceipt_id; mapping_versionMovement reconciliation
Box openingsource_box_ref identifies the specific box50 lancets available, not usedsource_label_ref for opened boxBox movement recordBox-label check before disposal
Patient useunit_of_use_di=10417; patient_encounter_refquantity=1; quantity_uom=lancetlot_number=L-5530 from source boxsource_box_ref; mapping_versionRecorded use confirmation
Correction or reconciliationAffected receipt, box or use recordExplicit affected quantity and unitRetained label evidenceOriginal event; prior mapping_versionchange_reason; approved_by

For US medical devices, FDA’s GUDID guidance, Section III.A.(2), states that PI values are not part of GUDID; it distinguishes these values from flags indicating which PI attributes appear on the label. A lot-attribute flag is not L-5530. Here, that actual lot comes from the box-label record, not a virtual-identifier lookup. See DI versus PI terminology for the broader distinction.

The joins do separate jobs: the mapping connects package and unit roles; source_box_ref connects the observed lot; the use event connects that evidence to patient_encounter_ref. This chain supports local recall readiness without treating reference data as patient-use history.

09Integrations and recovery when a link is missing

As a practical interface safeguard, transmit the identifier role and quantity unit alongside the value between receipt, inventory and patient-use records. Preserve identifiers as strings: their digit patterns are not instructions for quantities or package levels. Keeping these fields explicit supports data integrity by design without relying on a receiving system to infer meaning.

Treat a failed lookup as a data exception, not proof that the physical product is invalid. Route an unmatched package record to an unresolved mapping task for qualified review. Avoid silently creating a Unit of Use DI or approving a patient-use association to bypass the mismatch. Product disposition remains a separate decision under local procedures.

Recovery case: the source box was discarded

In this hypothetical case, the lancet box was discarded before its lot was transferred to the patient-use record. A retained label image and an unambiguous source-box reference may support reconstruction. Follow that backward genealogy trace to the actual source rather than borrowing a lot from a nearby box. An expected delivery lot or aggregate stock balance alone does not establish which box supplied the device.

If the source cannot be established, retain the unresolved status, identify the missing field and preserve the investigation context. Leave the lot unresolved rather than backfilling a guess merely to complete the record.

For a supported correction, record the prior value, replacement value, supporting source, reason and qualified approver. Keep mapping corrections distinguishable from patient-use corrections in the audit trail, so review can assess affected historical events without overwriting their provenance. A qualified person approves the record change.

10Failure modes that break individual-use traceability

In the fictitious lancet example above, the main risk is a plausible identifier recorded with the wrong operational meaning. Review these failures against the established mapping and transaction records:

  • Primary DI treated as one lancet: Recording Primary DI 20417 against a patient with quantity 1 loses the distinction between package identity and intended device-use quantity. Keep the identifier role and quantity unit explicit, and use the approved mapping above. Storing the Primary DI as context is not itself the problem.
  • Case identifier in the use field: Copying Package DI 30417 into the patient-use identifier field mistakes receipt context for the individual-use reference. Retain it in the receipt record; check the use field against the approved relationship to Unit of Use DI 10417.
  • Box discarded before lot capture: Losing lot L-5530 and its association with the source contents leaves a gap that the correct virtual identifier cannot reconstruct. Preserve the source-label association before disposal; follow the recovery approach above if it is already missing.
  • Unpacked stock counted twice: Check the earlier inventory reconciliation for cases retained as available stock after their contents have also been booked as boxes.
  • Conversion factors silently changed: Compare historical transactions with their recorded mapping version, rather than recalculating them using a replacement factor. Route proposed record changes to a qualified person for approval.

These are targeted checks for exception-based review, not a substitute for resolving the underlying evidence gaps.

11A qualified review before relying on the record

Use this proposed local acceptance checklist alongside the configuration, identifier-comparison and record-field sections above:

  • Confirm the unit-of-use boundary and identify the base package.
  • Review the documented Primary DI, Unit of Use DI and package relationships.
  • State every quantity unit; distinguish physical label capture from mapped values.
  • Exercise the fictional receipt, unpacking, box-opening, individual-use and missing-lot cases.
  • Reconcile balances through package transformations without treating converted stock as observed use.
  • Keep a missing mapping or source lot visible for exception-based review; never replace it with a guessed value.

Under this proposed control, a qualified person approves record changes and evaluates their effect on historical events. Include that evaluation in the audit trail review workflow. Keep software support separate from human approval and product disposition.

The acceptance objective is a record chain a reviewer can follow from recorded use to the appropriate source box, lot, package relationship and receipt—without substituting an inventory assumption for use evidence.

Frequently asked questions

Q.Can the Unit of Use DI alone distinguish which physical lancet was used?+

Do not infer physical-item identity from the Unit of Use DI alone. For a receipt-to-use record, distinguish the mapped device identifier from the evidence documenting a particular use: the source box, its lot, the clinical event and any available item-specific identifier. If individual lancets cannot be distinguished in the records, preserve that limitation rather than inventing serial-level precision. A backward genealogy trace can then follow the documented connection without claiming more detail than was captured.

Q.Can an existing Primary DI fill a blank Unit of Use DI field while the mapping is investigated?+

As a record-design practice, leave the unresolved field explicitly pending rather than copying the Primary DI merely to satisfy a required entry. Preserve the scanned identifier in its original field, attach the source-box reference and route the mapping question to a qualified reviewer. The reviewer should approve any resulting record change before operational use. An exception-based review queue can separate incomplete mappings from approved ones without making a populated field look like a resolved identification decision.

Q.How can an opened box remain traceable when several clinical stations share its contents?+

Use a controlled transfer record that preserves the source-box reference, mapped Unit of Use DI, lot, destination station and quantity transferred. Keep those details associated with each segregated group after it leaves the box; do not rely on staff remembering where loose units originated. Record further transfers against the same source relationship. Bin-level lot genealogy provides a useful operational pattern, but the local procedure should separately address whether handling and storage preserve suitability for use.

Q.How should an existing mapping be reviewed when a later delivery has a different case size?+

Treat the changed case size as a reason to check the incoming package configuration, not as permission to overwrite the existing mapping. Compare the case identifier, contained box identifier, boxes per case and devices per box against the delivery labels and approved master record. Determine whether the difference concerns packaging, a receiving error or a different product. Keep earlier receipts tied to their original unit-of-measure conversion, and obtain qualified approval before applying a revised mapping.

Q.How should unused units returned from a station be represented without assuming they are suitable for reuse or restocking?+

Record the return as a separate movement into a pending-disposition status, retaining the source box, lot, originating station, quantity and available handling history. Do not let that movement automatically increase available stock or erase the earlier issue. A designated reviewer can assess disposition under the applicable local procedure and product instructions. In perpetual inventory, distinguish physical quantity present from quantity available for issue; this prevents an accounting return from silently becoming a suitability decision.

Q.Can a case receipt or inventory decrement establish that a device was actually used on a patient?+

Neither event, by itself, establishes patient use in a traceability record. A receipt documents arrival; a decrement might represent transfer, waste, adjustment or consumption. Establish the patient-use connection through a separate clinical event record that links the mapped Unit of Use DI and source lot to an authorized local patient reference. Keep the event type explicit. Discrete consumption is a useful recording pattern, but an inventory transaction should not be relabeled as clinical evidence.

Q.How should a lot transcription error in an existing patient-use record be corrected?+

Use a controlled amendment rather than silently replacing the lot. Preserve the original entry, record the corrected value, explain the reason and identify the supporting box-label or transfer record. Have a qualified person approve the correction, and assess whether any reports or downstream records also need amendment. If the correct lot remains uncertain, document that uncertainty instead of choosing the most likely value. An audit trail helps retain the relationship between the original entry and its correction.

Q.Which receipt-to-use fields should a downstream traceability partner receive, and which patient references should remain local?+

Define an exchange dataset around the partner’s task: relevant package identifiers, mapped Unit of Use DI, lot, quantities with units, event type and time, and references needed to connect transfers. As a privacy-conscious design practice, keep direct patient identifiers and the patient-reference lookup local unless an authorized purpose specifically calls for disclosure. Use a controlled event reference for reconciliation. Data integrity by design helps frame an exchange that preserves traceability without exporting the entire clinical record.

Primary sources

  • FDA Global Unique Device Identification Database (GUDID) guidance (December 17, 2024)
  • 21 CFR 830.310 Information required for unique device identification
Software that covers Unit of Use DI
V5 Ultimate Medical Device MES
Device history records built from signed steps at the workstation: component lots, configured step order, inspections, UDI and…
V5 Ultimate for EU MDR
V5 assembles it as one file that a Notified Body auditor can navigate in an hour.
Talk to us about Unit of Use DI

Want to see how Unit of Use DI could fit into your own records and workflows? Explore the related V5 pages or talk to our team about what applies to your operation.

Start free
Back to glossary
Related terms
  • → GUDID
  • → UDI
  • → UDI-DI vs UDI-PI
  • → Convenience Kit

Next Step

Try V5 with your own records, or ask a question first. Ask V5 opens with an editable question; nothing is sent until you choose to.

Start your free trial Browse All Features

Showing the site for the United States. Local spelling, dates and prices are applied automatically; change the language at the top of the page.

V5 Ultimate
Ultimate

Warehouse, quality and manufacturing software for regulated operations.

ProductIndustriesPricingResourcesSecurity & TrustCompanyLegal Centre

© S.G. Systems, LLC