V5 Ultimate
Ultimate
PricingResourcesCompany
English (original)العربيةDeutschΕλληνικάEspañolFrançaisItalianoעברית日本語한국어NederlandsPolskiPortuguêsSvenska
Talk to us Log in Start free trial
Food & Beverage
  • Bakery & Confectionery
  • Food Processing
  • Ingredients & Dry Mixes
  • Sausage & Meat Products
  • Produce Packing
  • Pet Food & Pet Supplements
  • Dairy & Chilled Foods
  • Beverages & Liquid Manufacturing
  • Infant Formula
Pharma & Life Sciences
  • Radiopharmaceuticals
  • Pharmaceutical
  • Medical Devices
  • Veterinary Pharmaceuticals
  • Blood & Tissue
  • Diagnostics & IVD Kits
  • Reference Materials & Standards
  • OTC Topical Creams & Gels
Supplements & Personal Care
  • Dietary Supplements
  • Cosmetics & Personal Care
  • Cannabis & Hemp Manufacturing
  • Fragrances & Perfumery
  • Soaps & Personal Hygiene
  • Botanical Extracts & Essential Oils
Chemicals & Materials
  • Plastics & Resins
  • Agricultural Chemicals
  • Specialty & Industrial Chemicals
  • Printing Inks, Pigments & Construction Chemicals
  • Lubricants & Metalworking Fluids
  • Coatings, Adhesives & Sealants
Other Manufacturing
  • Consumer Products
  • Electronics & Electrical Assembly
  • Textiles & Nonwoven
  • Contract Manufacturing & Co-Packing
  • Packaging & Food-Contact Materials
  • Regulated Warehousing & Distribution
Explore all industries
  • Warehouse & TraceabilityReceive, store, pick and trace
  • Production & PlanningPlan jobs and guide production
  • Quality & LaboratoryTest, investigate and review
  • Documents & TrainingControl procedures and qualifications
  • Equipment & PerformanceMaintain assets and measure losses
  • Orders & IntegrationsConnect customers, suppliers and systems
  • Outputs & InsightsReports, KPIs and label design
Why V5? Product & Features
Why V5?Product & Features
  • Warehouse & TraceabilityReceive, store, pick and trace
  • Production & PlanningPlan jobs and guide production
  • Quality & LaboratoryTest, investigate and review
  • Documents & TrainingControl procedures and qualifications
  • Equipment & PerformanceMaintain assets and measure losses
  • Orders & IntegrationsConnect customers, suppliers and systems
  • Outputs & InsightsReports, KPIs and label design
Explore all industries
    • Bakery & Confectionery
    • Food Processing
    • Ingredients & Dry Mixes
    • Sausage & Meat Products
    • Produce Packing
    • Pet Food & Pet Supplements
    • Dairy & Chilled Foods
    • Beverages & Liquid Manufacturing
    • Infant Formula
    • Radiopharmaceuticals
    • Pharmaceutical
    • Medical Devices
    • Veterinary Pharmaceuticals
    • Blood & Tissue
    • Diagnostics & IVD Kits
    • Reference Materials & Standards
    • OTC Topical Creams & Gels
    • Dietary Supplements
    • Cosmetics & Personal Care
    • Cannabis & Hemp Manufacturing
    • Fragrances & Perfumery
    • Soaps & Personal Hygiene
    • Botanical Extracts & Essential Oils
    • Plastics & Resins
    • Agricultural Chemicals
    • Specialty & Industrial Chemicals
    • Printing Inks, Pigments & Construction Chemicals
    • Lubricants & Metalworking Fluids
    • Coatings, Adhesives & Sealants
    • Consumer Products
    • Electronics & Electrical Assembly
    • Textiles & Nonwoven
    • Contract Manufacturing & Co-Packing
    • Packaging & Food-Contact Materials
    • Regulated Warehousing & Distribution
PricingResourcesCompany
Start free trial Log in Talk to us
HomeGlossaryActive Substance Master File
Records · The complete guide

Active Substance Master File

In short

Active Substance Master File is a dossier procedure that protects active-substance know-how while supporting authority assessment and the applicant’s full quality responsibility.

4,463 words · ~21 min read
Two reviewers compare applicant and restricted version columns on a tablet beside a laptop submission register, two closed blue folders and a small vial.
Applicant and restricted document references remain distinct during version review.
On this page
  1. 01What an Active Substance Master File records
  2. 02Guidance context, CEP records and separate quality decisions
  3. 03AP, RP and the applicant’s quality responsibility
  4. 04Build the authority-specific submission record
  5. 05Model versions, permissions and receipts separately
  6. 06Coordinate the holder and application submission histories
  7. 07Connect holder changes to each affected authorisation
  8. 08Worked case: AP-8 arrives against an RP-7 receipt
  9. 09Worked case: an RP change notice with an open variation
  10. 10Worked case: product P’s LoA does not establish Q’s coverage
  11. 11Recover document and integration exceptions
  12. 12Review the evidence chain before documentary closure
On this page · 12 sections
  1. 1What an Active Substance Master File records
  2. 2Guidance context, CEP records and separate quality decisions
  3. 3AP, RP and the applicant’s quality responsibility
  4. 4Build the authority-specific submission record
  5. 5Model versions, permissions and receipts separately
  6. 6Coordinate the holder and application submission histories
  7. 7Connect holder changes to each affected authorisation
  8. 8Worked case: AP-8 arrives against an RP-7 receipt
  9. 9Worked case: an RP change notice with an open variation
  10. 10Worked case: product P’s LoA does not establish Q’s coverage
  11. 11Recover document and integration exceptions
  12. 12Review the evidence chain before documentary closure
AI · Explain it for MY operation

How does Active Substance Master File apply to your shop floor?

Pick your industry and scale — Ask V5 rewrites the definition in your context, gives a worked example, and shows what V5 does on day one.

Your scale

01What an Active Substance Master File records

Active Substance Master File is an active-substance dossier referenced for authority assessment in support of a medicinal product marketing-authorisation application or variation. This descriptive definition places the ASMF in the application’s documentary chain: it identifies supporting information about the active pharmaceutical ingredient, rather than serving as a manufacturing approval.

ASMF is the procedure formerly known as European Drug Master File (EDMF). Its objective is to protect the active-substance manufacturer's confidential intellectual property or know-how while allowing the applicant or marketing-authorisation (MA) holder to take full responsibility for the medicinal product and the active substance's quality and quality control. The ASMF holder has ultimate responsibility for the ASMF; holder, applicant and MA holder remain distinct roles even where one organisation fills several roles. These are the guideline's introductory and role definitions, not an optional division of quality responsibility.

For this EU/EEA human-medicine reference, EMA advice 3.3.6 limits the ASMF concept to a well-defined active substance: it cannot be used for excipients, finished products or biological active substances. Those are substantive eligibility exclusions, not merely topics omitted here. Veterinary procedures and current UK/Northern Ireland arrangements are separate scope questions; see the Windsor Framework medicines provisions. No confidential manufacturing recipe is reproduced in the documentary examples.

The practical focus is the administrative evidence chain. A useful record connects the dossier identity to the relevant product, application and authority, then answers the following questions without treating every document as interchangeable:

  • Which dossier and version does the application reference?
  • Who permits the authority to assess that dossier?
  • Which documents reached which recipient?
  • How does a communicated change connect to a particular application?

The examples therefore use document identifiers, roles, permissions and submission histories. Manufacturing recipes and restricted technical content remain outside them. The aim is to make the administrative relationship reviewable without reproducing confidential substance-manufacturing information.

02Guidance context, CEP records and separate quality decisions

The European Medicines Agency (EMA) currently lists the final ASMF guideline Revision 4; the document is Revision 4/Corr, dated 8 November 2018, with an effective date of 17 June 2019. The retained EMEA naming in older references and EMEA/ASMF identifiers relates to the Agency's earlier European Medicines Evaluation Agency name, not a second present-day authority. Read that guideline alongside current human-medicines procedural advice, rather than extending its older geographical footnotes to today's arrangements.

For EU/EEA human-medicine dossier planning, consult the EMA ASMF procedure page for the applicable guideline and the human-medicines pre-authorisation advice for EMA procedural scope. These are guidance resources, not freestanding legislation. Keep the procedure and authority identified in the record rather than treating EMA centralised submission advice as instructions for every national application.

For EMA centralised human-medicine submissions, procedural advice 3.3.6.4 recommends communicating the allocated EMEA/ASMF reference number to the applicant or marketing authorisation holder for use in all future submissions. In the recommended record model, that reference identifies the ASMF submission history; it is not a substitute for the distinct evidence below.

RecordPurposeSeparate evidence
ASMF referenceIdentify the dossier historyVersion and submission records
Letter of Access (LoA)Document permission scopeRelevant product and authority
Existing CEP or register entryIdentify the certificateRoute-selection assessment
Site-qualification recordDocument site assessmentGMP qualification decision
Batch-disposition recordDocument the lot decisionBatch review and release evidence

This is a practical comparison of documentary questions, not a declaration that alternative submission routes are acceptable for every substance. Where an existing certificate of suitability is being considered instead, keep its identity and the rationale for route selection separate from the ASMF submission history. A register reference belongs with the certificate evidence, not in place of the assessment explaining the proposed route.

The recommended evidence model does not accept an ASMF or LoA as proof of good manufacturing practice (GMP) site qualification or lot release. Those decisions have their own supporting records and accountable reviewers. Documentary closure therefore means closing the defined dossier-reference task, not closing every quality decision associated with the substance. A useful review question is whether each conclusion points to evidence answering that specific question, rather than merely to a familiar identifier.

03AP, RP and the applicant’s quality responsibility

Under guideline section 4, the Applicant's Part (AP) is non-confidential to the applicant or MA holder but remains confidential to third parties: written ASMF-holder consent is required for onward submission. The Restricted Part (RP) is closed to the applicant. National Competent Authorities and EMA have the complete information required for assessment; a filename-only administrative register cannot replace that access. For human dossiers in Common Technical Document (CTD) format, separate AP and RP summaries are both presented as Quality Overall Summaries (QOS), with the restricted summary separately controlled.

The documentary vocabulary is Applicant’s Part (AP), Restricted Part (RP), Quality Overall Summary (QOS) and Letter of Access (LoA). A recommended permissions model separates applicant-facing AP records, holder-restricted RP records and authority-facing assessment packages. These are record-handling categories, not substitutes for the submission arrangements applicable to a particular dossier.

  • Applicant-facing records: keep the AP and its associated summary accessible to designated applicant reviewers. Delivery to the applicant should not be treated as public availability or permission for onward disclosure.
  • Holder-restricted records: keep RP and its QOS out of applicant-facing workspaces, including previews and copied passages. Applicant receipt of AP does not permit third-party disclosure without written holder consent.
  • Authority-facing packages: maintain a separate controlled record of the documents intended for assessment. An administrative ledger can identify restricted documents and their holder without reproducing their contents.

This recommended role-based access control model should cover search results and exports as well as document folders. A useful confidentiality review asks who can retrieve the content, not merely who can see its filename.

For EU/EEA human-medicine dossiers, section 6 of the ASMF guideline connects the applicant or marketing authorisation holder’s information access with taking full responsibility for active-substance quality in the medicinal product. Confidentiality should therefore be managed alongside, rather than used to dismiss, questions about whether applicant reviewers have the information needed for their quality responsibilities.

For EU/EEA human-medicine dossiers, that section also recommends including all relevant AP details in the MA dossier’s QOS. As a practical review control, distinguish this applicant-facing summary from any summary record associated with restricted material.

04Build the authority-specific submission record

Guideline section 5 separates recipients: the holder supplies the applicant with the latest AP, its summary and the LoA where not previously submitted for that product; the authority receives the ASMF, Submission Letter and Administrative Details, and the applicable LoA. In EMA centralised advice 3.3.6.1, first submission includes the dossier and expert curriculum vitae; both first submission and introduction of an existing ASMF for another medicinal product require LoA, Submission Letter/Administrative Details and a change-notification commitment. Subsequent approved-ASMF changes require the administrative documents and relevant revised AP and/or RP sections. The applicant/MA holder separately supplies the application references and relevant AP/LoA/commitment documents described in 3.3.6.2. A holder package is not the applicant's completed package.

For EU/EEA human-medicine dossiers, the Annex 2 Letter of Access template describes permission to refer to and review the ASMF in support of marketing-authorisation applications or variations. A recommended submission record therefore connects the permission to the particular product, applicant and receiving authority, rather than treating the letter as a substance-wide credential.

For EU/EEA human medicines in the centralised procedure, EMA’s section 3.3.6.1 procedural advice lists AP, RP, QOS and the expert’s curriculum vitae for a first ASMF submission; for subsequent changes to an approved ASMF, it identifies the relevant revised dossier sections. This distinction provides a useful basis for separating an initial-package inventory from an update inventory.

Recommended recipient-specific checklist

  • Identity and destination: holder identity and contact, substance identity, product, applicant and receiving authority.
  • References and contents: internal and allocated references, AP/RP/QOS identifiers, LoA reference, submission letter and administrative details.
  • Application connection: the supported application or variation, with receipt evidence linked to the relevant submission.
  • Document disposition: distinguish documents attached now from documents referenced through an earlier submission; identify the earlier record rather than marking both categories simply present.

These are recommended administrative fields, not a universal prescribed form. An update inventory can also link to the associated change-control record, while retaining the document-level account of what was transmitted.

For EU/EEA human-medicine ASMF administration, the Annex 3 submitted-document list and change-table instructions include a QOS or appropriate summary and identify a Table of Changes for an update to a currently authorised ASMF. For these EU/EEA human-medicine updates, Annex 3 recommends keeping the table separate from the main submission cover letter. For EU/EEA human-medicine ASMF changes previously authorised in a national or European procedure, Annex 3 recommends annotating the table with the procedure number.

Historical-document recovery benefits from distinguishing a missing LoA copy, an unconfirmed prior submission and an explicitly uncovered application. The first is a retrieval gap; the second leaves submission history uncertain; the third identifies a permission-scope gap. Recommended records preserve those different conditions without assumed dates or invented approval references.

05Model versions, permissions and receipts separately

Guideline section 4 calls for unique, independent AP and RP version-control numbers; their suffixes need not match. Section 6 calls for the applicant's dossier AP to be the most recent and identical to the AP supplied by the holder to the authority. EMA centralised advice 3.3.6.2.2 further aligns the Agency's current submitted ASMF version, the AP declared in the application form and Module 3. That submission-validation baseline is not automatically the authorised baseline of every product already linked to the ASMF.

For an EU/EEA human-medicines ASMF administrative record, a practical design separates ASMF identity, document version, application access, authority submission and change review. This supports distinct histories without treating a permission, a transmitted document and a review conclusion as interchangeable evidence.

The record diagram below is a recommended evidence model, not an official form or mandated database structure. Each arrow represents an explicit relationship supported by a document or recorded review, rather than an inference from a filename.

Assign document_type, version_id and bundle_id independently. The type identifies AP, RP or QOS; the version identifies the particular document; the bundle records their reconciled relationship. A matched AP/RP/QOS bundle means that relationship has been reviewed against supporting records. Matching suffixes alone are not evidence of reconciliation, and different suffixes need not imply an error.

Preserve predecessor relationships through document control, rather than replacing earlier entries. Keep an internal ASMF identifier distinct from any authority-allocated reference, with the reference’s issuing authority recorded. This avoids presenting a local tracking label as an external reference.

Represent a shared ASMF through separate product–authority links. Associate each access record with its supporting permission document and each submission receipt with the actual recipient and document versions. Retain receipt_reference separately from conclusion_reference; leave an unsupported relationship unresolved rather than copying a reference from another application.

For each relationship, record the reviewer, supporting document and remaining uncertainty. A missing attachment or ambiguous version mapping can remain a visible review issue without erasing the known history. Keep restricted content in its controlled location; expose only authorised metadata in the administrative view, with references that permit appropriately authorised reviewers to locate the supporting material.

Recommended ASMF record relationships

ASMF master

Holder and substance identity.

  • asmf_id
  • holder_id
  • substance_id

Dossier version

Version and access metadata.

  • document_type
  • version_id
  • bundle_id
  • access_class

Application access

Product, authority and permission linkage.

  • product_id
  • authority_id
  • applicant_id
  • loa_id

Submission record

Recipient-specific document and receipt history.

  • submission_id
  • version_ids
  • submitted_at
  • receipt_reference

Change review

Change assessment and recorded conclusion.

  • change_id
  • authorised_reference
  • proposed_reference
  • variation_status
  • conclusion_reference
Application and submission records connect dossier versions with permissions, recipients and change reviews.

06Coordinate the holder and application submission histories

EMA centralised advice 3.3.6 expects the ASMF dossier and necessary documents to arrive simultaneously with the planned marketing-authorisation application (MAA) or variation. Applications cannot be validated until the necessary documents are received in satisfactory form. These scoped procedural expectations are distinct from the recommended coordination ledger below; no universal dispatch interval, national portal sequence or receipt-to-approval period follows from it.

For an EU/EEA human-medicines ASMF record, the workflow below is a recommended administrative sequence, not a universal submission procedure. It describes records and decision points rather than portal operations. The shared reference is the intended application event; the holder’s ASMF submission and the applicant’s application remain separate histories linked to that event.

For each party’s submission history, record the receiving authority, package identity, planned event, actual dispatch and acknowledgement. A holder’s receipt belongs to the holder’s package; it is not a substitute for evidence that the applicant’s package arrived. If either planned event changes, retain the earlier plan and connect the revised intention to the corresponding package history. This makes a coordination gap visible without rewriting the chronology.

Keep timing and format decisions attached to the applicable route and authority instructions. Do not derive a default deadline, portal sequence or national practice from an EMA centralised reference-number process. The coordination record can identify the instruction used and the event it governs without treating that instruction as transferable to another recipient.

Using the record model above, distinguish intended, dispatched, acknowledged and assessed events instead of collapsing them into a single status. Link correspondence to both its package and application. For practical exception-based review, flag missing connections rather than infer an outcome from neighbouring records. These internal categories organise evidence; they do not themselves establish a regulatory conclusion.

Recommended ASMF administrative evidence chain
  1. 1
    Map the referenceLink holder, substance, product, applicant and receiving authority.
  2. 2
    Check permissionAssociate the LoA with the intended application record.
  3. 3
    Reconcile documentsCompare AP, RP and QOS relationships without exposing restricted content.
  4. 4
    Coordinate submissionConnect each package to its intended application event.
  5. 5
    Record receiptPreserve recipient acknowledgements separately from assessment conclusions.
  6. 6
    Trace the changeConnect notifications, affected applications, change tables and variation records.
  7. 7
    Review the conclusionRetain the authorised baseline until the applicable outcome supports replacement.
A record sequence for coordination and review, not a universal authority procedure.

07Connect holder changes to each affected authorisation

For EU/EEA human-medicine ASMFs, section 7 of the guideline states that holders shall not modify ASMF content without informing each applicant or marketing authorisation holder and each National Competent Authority/EMA. This is guideline wording, not a separately cited statutory provision.

Section 7 recommends providing the updated ASMF with its revised version number to interested parties, subject to the AP/RP recipient confidentiality boundaries: it does not make restricted information applicant-accessible. It also addresses notification of changes through the appropriate variation procedure. The administrative view records who received which authorised document, not a common unrestricted attachment for all recipients.

Recommended documentary adoption control

EMA centralised advice 3.3.6 states that linked marketing authorisations integrate an ASMF update only once the applicable variation is submitted and positively concluded. This is a sourced procedural condition, not merely an optional conservative record practice. Separately, the recommended ledger preserves authorised and proposed references and the conclusion evidence; holder notification or submission receipt does not establish that positive conclusion. No universal variation category or implementation timetable is inferred.

A practical change-control record can connect the holder’s notice to separate entries for each affected authorisation. Recommended fields are:

  • The linked product, authorisation and authority, with the existing and proposed ASMF references.
  • The holder’s notification and revised-version reference, linked without replacing the existing reference.
  • The applicable variation record, its documented status and the evidence supporting any positive conclusion.
  • The reviewer’s adoption decision and unresolved questions, with the earlier reference preserved for comparison.

This structure keeps a shared holder change from becoming a single assumed adoption decision for every linked product. It also lets reviewers distinguish an outstanding communication from an outstanding variation conclusion without reopening unrelated submission records.

For access-withdrawal records, retain the historical Letter of Access, withdrawal correspondence and affected application links rather than deleting the earlier permission history. This recommendation preserves traceability; it does not determine the legal consequences of withdrawal for any particular authorisation.

08Worked case: AP-8 arrives against an RP-7 receipt

In this fictional retrospective case, ASMF-K9 was linked to product P-K9 and authority A. The recorded bundle was AP-7/RP-7/QOS-7, with LoA-L7. These are illustrative record identifiers, not authority-issued approval numbers. The review concerned documentary relationships, not the technical acceptability of a manufacturing change. Here QOS-7 denotes the administrative summary set, comprising separately controlled AP-QOS-7 and RP-QOS-7; it does not expose the restricted summary to the applicant.

AP-8 had been received, while the authority receipt identified RP-7. Eli Turner, the responsible reviewer, opened change-table record CH-K9 within the fictional organisation’s change-control record. Eli preserved AP-7 and AP-8 as separate documents and linked the existing RP-7 receipt rather than replacing it. The earlier bundle remained available for comparison.

Comparison entryRecorded evidenceCH-K9 finding
Applicant’s PartAP-7 retained; AP-8 receivedNew document received; bundle relationship unresolved
Restricted PartExisting authority receipt identifies RP-7No receipt for a different RP recorded
SummaryQOS-7 in earlier bundleRelationship to AP-8 unconfirmed
Access referenceLoA-L7 linked to P-K9 and authority AExisting link preserved

Eli requested clarification from the holder identifying which RP and QOS versions accompanied AP-8, whether either remained unchanged, and which submission correspondence connected that combination to authority A. The request referenced CH-K9 and the documents already held, so a response could resolve the relationship without erasing the discrepancy. No RP-8 or QOS-8 record was created merely because AP-8 had arrived; matching suffixes were not treated as evidence.

At the review endpoint, CH-K9 recorded version reconciliation pending holder clarification, with Eli Turner responsible for follow-up. AP-8 remained a received document, not a replacement bundle. The unresolved relationship and clarification request stayed linked to both AP versions and the RP-7 receipt. No authority conclusion was entered.

09Worked case: an RP change notice with an open variation

In this separate fictional retrospective case, an ASMF holder had sent an RP change notification concerning an authorised human medicine. At the review point, the linked marketing authorisation variation had not reached a documented positive conclusion. The applicant’s administrative file contained the holder’s notice and its proposed reference, not the restricted manufacturing detail. These are case assumptions, not a prescribed record format.

Applying the adoption gate described above, the reviewer retained the authorised reference for comparison. The notice was associated with the proposed reference and linked to the applicable variation record, whose status remained open. The proposal was not marked as integrated into the marketing authorisation. The supplier change notification entry therefore documented communication received, while the separate variation entry tracked the unresolved assessment. Neither entry overwrote the authorised reference. This preserved a readable history of what had been communicated and what remained pending, without adding restricted content to the applicant’s file.

For a later review, the recommended follow-up evidence was the relevant documented conclusion, its connection to the affected product and authority, and a recorded human decision on whether to transition the reference. That decision would identify the reference retained or superseded and the supporting conclusion. No approval identifier was assumed. The unresolved status described the evidence position at that review point; it did not imply that the variation had failed.

10Worked case: product P’s LoA does not establish Q’s coverage

In this fictional retrospective case, the retained Letter of Access (LoA) expressly identified product P. A separate product Q record referenced the same ASMF holder, but contained no documented permission covering Q. The review concerned what that retained letter established—not a universal interpretation of every LoA. Shared holder details alone did not resolve the missing relationship.

The reviewer compared product, applicant, receiving authority and application scope before considering reuse of P’s access reference. P’s documented linkage remained intact. Q’s permission relationship stayed unresolved rather than inheriting P’s status. The exception record identified the missing scope evidence, making the distinction visible during exception-based review. It did not treat absence of documentation as proof that permission had never existed.

Recovery first distinguished locating evidence of an already covering LoA from introducing the existing ASMF for a new product. Correspondence could help locate or explain an existing covering document, but did not substitute for the appropriate LoA and submission/administrative documents for Q. The reviewer retained P's evidence and requested Q-specific scope and document support. Q's relationship stayed unresolved until that support was reviewed; neither the shared holder nor a copied status supplied it, and no approval identifier was invented.

11Recover document and integration exceptions

For ASMF administrative records, a useful integration design connects the document repository, regulatory application tracker, correspondence register and supplier master through controlled references. Exchange identifiers, relationships and authorised metadata rather than copying restricted content into broadly accessible systems. A link can identify the source record and its custodian without exposing the document itself. Keep access permissions attached to the source record rather than treating a successful exchange as permission to read it.

Route duplicate ingestion, out-of-order correspondence, ambiguous holder identity and unmatched acknowledgements into an exception-based review queue. Preserve the incoming item, flag the unresolved relationship and assign a reviewer instead of silently merging records. Record the proposed match separately from the confirmed match, with the review decision and its basis. Arrival order alone is a poor basis for deciding which application or submission a message concerns.

Link deficiency-response correspondence to the application and document versions it supplements. For holder-name or contact changes, retain the earlier identity details and the correspondence supporting the amendment. An audit trail review workflow can structure review of those administrative edits. Treat a clerical correction as an identity-record update, not evidence that technical content or application scope has changed.

12Review the evidence chain before documentary closure

Use these recommended administrative review prompts within the evidence boundaries established above:

  • Confirm the active substance, holder, ASMF reference and application identity.
  • Check permission scope against the product and receiving authority.
  • Reconcile AP, RP and QOS references, retaining their documented relationships.
  • Match receipts to recipients, submissions and document versions.
  • Identify affected applications and record unresolved exceptions, with links to supporting correspondence.
  • Record the named human reviewer’s conclusion, its limits and any follow-up.

For an internal no-change statement, identify the compared baseline, the holder communication relied upon, its scope and any outstanding reconciliation issue. Silence or a missing update is not affirmative evidence of unchanged particulars.

Preserve the supporting history through document control. A completed checklist records a review outcome; it cannot manufacture missing evidence. Make the reviewer’s decision explicit through a signature meaning statement. The documentary FAQs below address individual record questions separately.

Frequently asked questions

Q.What documentary record can an applicant keep when RP content is not in its possession?+

A practical applicant-side record can identify the ASMF holder, active substance, product, authority, AP version held, RP version reported by the holder, and the correspondence supporting those references. Keep holder declarations, submission confirmations and authority acknowledgements distinguishable: each documents a different event. Describe an RP reference as holder-reported unless direct documentary confirmation supports stronger wording. An access-controlled index can point to this administrative evidence without containing confidential manufacturing details; its permissions belong within the organisation’s role-based access controls.

Q.How should a missing historical LoA copy be distinguished from evidence that no LoA was submitted?+

A missing local copy establishes a document-retrieval gap, not the historical fact of non-submission. A useful lookback record distinguishes the letter itself, correspondence referring to it, submission inventories and authority acknowledgements. Record which product and authority each item concerns, and describe unresolved submission status explicitly. If a replacement copy arrives, preserve its retrieval history rather than presenting it as newly issued. The audit trail can distinguish original issue, reported submission and later recovery without collapsing those events.

Q.How can a shared ASMF be traced across products with different authority submission histories?+

For EU/EEA human medicines, section 5 of the EMA ASMF guideline recommends identical documentation to each relevant authority when the same active substance supports different product applications. A practical register nevertheless separates each product–authority relationship, recording its LoA, submission history, document versions and outstanding correspondence. The shared active substance identity is the connecting reference, not proof of matching submission status. Product-context tagging can make those separate histories easier to distinguish without duplicating the underlying documents.

Q.How should a deficiency response be linked to the document versions it supplements?+

A useful response index connects the authority’s deficiency letter, individual question, response document, affected AP or RP reference, and any replacement pages or complete revised document. Distinguish a supplemental explanation from a replacement version; neither label alone establishes the authority’s conclusion. Record the submission correspondence separately from the technical response. This document-control relationship preserves what the reviewer was answering, while the linked change-control record explains whether the response also introduced a proposed change to the dossier.

Q.What should be retained when the holder changes its name or administrative contact?+

A practical identity-history record preserves the previous and new names or contacts, the holder’s notification, the stated effective date where documented, and the affected ASMF references. It also distinguishes a contact update from a claimed change of legal entity; a revised email signature alone does not resolve that distinction. Related supplier change correspondence can identify affected products and authority communications. Historical letters remain attributable to their original issuer rather than being silently relabelled with the current name.

Q.How should a withdrawn LoA be recorded without deleting the earlier application history?+

For EU/EEA human medicines, section 7 of the EMA ASMF guideline states that the holder’s change-notification obligation remains valid until the holder withdraws the LoA. A practical withdrawal record preserves the original letter, withdrawal communication, stated scope, affected product–authority relationships and subsequent correspondence. It marks the access relationship as withdrawn without erasing earlier reliance on it. An audit-trail review can distinguish the withdrawal event from later administrative decisions rather than assigning undocumented consequences to the withdrawal itself.

Q.What distinguishes an internal ASMF identifier from an allocated EMEA/ASMF reference?+

A useful identifier register keeps a company’s local tracking key in a different field from an EMEA/ASMF reference supported by allocation correspondence. For each external reference, retain the issuing communication, its scope and the documents on which it appears. Avoid converting a local code into an apparently official reference through formatting or labelling. A naming-convention standard operating procedure (SOP) can explain the distinction and preserve aliases, so searches recover older records without implying that every identifier has the same origin or authority.

Q.What evidence belongs beside a statement that the active-substance particulars have not changed?+

A practical substantiation record identifies the comparison baseline, the particulars covered, the period addressed, the holder’s confirmation and the person evaluating that confirmation. It distinguishes an affirmative statement of no change from silence or the absence of a notification. Relevant change correspondence, unresolved discrepancies and the assessment rationale remain linked even when the final conclusion is unchanged. The record can support an Annual Product Quality Review (APQR), while the quality assurance process identifies who accepted the conclusion and its stated limitations.

Talk to us about Active Substance Master File

Want to see how Active Substance Master File could fit into your own records and workflows? Explore the related V5 pages or talk to our team about what applies to your operation.

Start free
Back to glossary
Related terms
  • → API
  • → Certificate of Suitability
  • → Type II Variation
  • → Change Control

Next Step

Try V5 with your own records, or ask a question first. Ask V5 opens with an editable question; nothing is sent until you choose to.

Start your free trial Browse All Features

Showing the site for the United States. Local spelling, dates and prices are applied automatically; change the language at the top of the page.

V5 Ultimate
Ultimate

Warehouse, quality and manufacturing software for regulated operations.

ProductIndustriesPricingResourcesSecurity & TrustCompanyLegal Centre

© S.G. Systems, LLC