V5 Ultimate
Ultimate
PricingResourcesCompany
English (original)العربيةDeutschΕλληνικάEspañolFrançaisItalianoעברית日本語한국어NederlandsPolskiPortuguêsSvenska
Talk to us Log in Start free trial
Food & Beverage
  • Bakery & Confectionery
  • Food Processing
  • Ingredients & Dry Mixes
  • Sausage & Meat Products
  • Produce Packing
  • Pet Food & Pet Supplements
  • Dairy & Chilled Foods
  • Beverages & Liquid Manufacturing
  • Infant Formula
Pharma & Life Sciences
  • Radiopharmaceuticals
  • Pharmaceutical
  • Medical Devices
  • Veterinary Pharmaceuticals
  • Blood & Tissue
  • Diagnostics & IVD Kits
  • Reference Materials & Standards
  • OTC Topical Creams & Gels
Supplements & Personal Care
  • Dietary Supplements
  • Cosmetics & Personal Care
  • Cannabis & Hemp Manufacturing
  • Fragrances & Perfumery
  • Soaps & Personal Hygiene
  • Botanical Extracts & Essential Oils
Chemicals & Materials
  • Plastics & Resins
  • Agricultural Chemicals
  • Specialty & Industrial Chemicals
  • Printing Inks, Pigments & Construction Chemicals
  • Lubricants & Metalworking Fluids
  • Coatings, Adhesives & Sealants
Other Manufacturing
  • Consumer Products
  • Electronics & Electrical Assembly
  • Textiles & Nonwoven
  • Contract Manufacturing & Co-Packing
  • Packaging & Food-Contact Materials
  • Regulated Warehousing & Distribution
Explore all industries
  • Warehouse & TraceabilityReceive, store, pick and trace
  • Production & PlanningPlan jobs and guide production
  • Quality & LaboratoryTest, investigate and review
  • Documents & TrainingControl procedures and qualifications
  • Equipment & PerformanceMaintain assets and measure losses
  • Orders & IntegrationsConnect customers, suppliers and systems
  • Outputs & InsightsReports, KPIs and label design
Why V5? Product & Features
Why V5?Product & Features
  • Warehouse & TraceabilityReceive, store, pick and trace
  • Production & PlanningPlan jobs and guide production
  • Quality & LaboratoryTest, investigate and review
  • Documents & TrainingControl procedures and qualifications
  • Equipment & PerformanceMaintain assets and measure losses
  • Orders & IntegrationsConnect customers, suppliers and systems
  • Outputs & InsightsReports, KPIs and label design
Explore all industries
    • Bakery & Confectionery
    • Food Processing
    • Ingredients & Dry Mixes
    • Sausage & Meat Products
    • Produce Packing
    • Pet Food & Pet Supplements
    • Dairy & Chilled Foods
    • Beverages & Liquid Manufacturing
    • Infant Formula
    • Radiopharmaceuticals
    • Pharmaceutical
    • Medical Devices
    • Veterinary Pharmaceuticals
    • Blood & Tissue
    • Diagnostics & IVD Kits
    • Reference Materials & Standards
    • OTC Topical Creams & Gels
    • Dietary Supplements
    • Cosmetics & Personal Care
    • Cannabis & Hemp Manufacturing
    • Fragrances & Perfumery
    • Soaps & Personal Hygiene
    • Botanical Extracts & Essential Oils
    • Plastics & Resins
    • Agricultural Chemicals
    • Specialty & Industrial Chemicals
    • Printing Inks, Pigments & Construction Chemicals
    • Lubricants & Metalworking Fluids
    • Coatings, Adhesives & Sealants
    • Consumer Products
    • Electronics & Electrical Assembly
    • Textiles & Nonwoven
    • Contract Manufacturing & Co-Packing
    • Packaging & Food-Contact Materials
    • Regulated Warehousing & Distribution
PricingResourcesCompany
Start free trial Log in Talk to us
HomeGlossaryPackage Device Identifier
Compliance · The complete guide

Package Device Identifier

In short

Package Device Identifier is a device identifier for a package configuration containing multiple units of the base package, excluding shipping containers, in US FDA GUDID terminology.

4,046 words · ~19 min read
A packaging operator in hairnet, mask, safety glasses and gloves scans the barcode on a shipping case of device boxes while a tablet shows the box-inside-case package hierarchy.
A Package Device Identifier names each package configuration above the base package; acceptance checks the contained DI and quantity against approved labeling.
On this page
  1. 01What a Package Device Identifier identifies
  2. 02Package DI beside neighboring identifiers
  3. 03US FDA scope and authority
  4. 04How the GUDID package fields fit together
  5. 05From proposed package change to controlled use
  6. 06Fictional case: changing the case configuration
  7. 07The completed packaging-acceptance record
  8. 08A wording-only revision assessed separately
  9. 09Moving package data without losing the hierarchy
  10. 10Failures that a successful scan can miss
  11. 11A review checklist with a clear stopping point
On this page · 11 sections
  1. 1What a Package Device Identifier identifies
  2. 2Package DI beside neighboring identifiers
  3. 3US FDA scope and authority
  4. 4How the GUDID package fields fit together
  5. 5From proposed package change to controlled use
  6. 6Fictional case: changing the case configuration
  7. 7The completed packaging-acceptance record
  8. 8A wording-only revision assessed separately
  9. 9Moving package data without losing the hierarchy
  10. 10Failures that a successful scan can miss
  11. 11A review checklist with a clear stopping point
AI · Explain it for MY operation

How does Package Device Identifier apply to your shop floor?

Pick your industry and scale — Ask V5 rewrites the definition in your context, gives a worked example, and shows what V5 does on day one.

Your scale

01What a Package Device Identifier identifies

Package Device Identifier is the device identifier for a US medical-device package configuration containing multiple units of the base package, excluding shipping containers. The FDA GUDID guidance defines it as “A device identifier for the package configuration that contains multiple units of the base package (does not include shipping containers).”

Package DI, GUDID Package DI and package UDI-DI are search aliases used here for this concept. This article uses the US FDA meaning; those search terms should not be taken as evidence that every jurisdiction uses identical terminology.

For US medical devices, the FDA GUDID guidance glossary describes a Device Package as “A package that contains a fixed Quantity of a particular version or model of a device”. The fixed configuration is the useful starting point for packaging review: what product configuration does this container represent, rather than what does the warehouse call it?

For US medical devices, footnote 17 of the FDA GUDID guidance describes a shipping container as “a container used during the shipment or transportation of devices, and whose contents may vary from one shipment to another.” The guidance’s Package DI glossary entry expressly excludes shipping containers.

In practical classification, ask whether the container represents a fixed product configuration or a variable transport load—not whether it is called a box, case or carton. Review the packaging specification and intended use together. A physical name alone does not resolve that question, and an outer container should not be classified solely by its position around other packages.

Keep transport identification separate from the product-package hierarchy during that review. For identification of the logistics unit, see SSCC pallet labeling. This separation helps reviewers avoid treating a transport label as the answer to a product-package identification question.

02Package DI beside neighboring identifiers

For US medical devices, FDA’s GUDID guidance, Package Information in GUDID identifies the Primary DI with the lowest package level containing a full UDI: the base package.

Comparison model: Primary DI, Package DI and Unit of Use DI are FDA GUDID field names. Acceptance reference, artwork revision and transport reference below are locally chosen quality-record fields, not FDA fields.

This reference architecture separates package-master data from production evidence: a package configuration record is not a lot record. Local acceptance records can reference both without merging their purposes.

Treat Unit of Use DI and convenience kits as neighboring identification topics; their eligibility, exceptions and detailed treatment belong in those entries. For identifier composition and issuing-system context, see UDI structure, DI versus PI and GTIN terminology. Keep this model format-neutral rather than treating GTIN terminology as universal to Package DIs.

Package identifiers and their neighboring records

Primary DI record

Base-package identity.

  • Primary DI
  • Device Count

Package entry

Higher configuration within the Primary DI record.

  • Package DI
  • Contains DI Package
  • Quantity per Package
  • Package Type
  • Package Discontinue Date
  • Package Status

Unit of Use reference

Separate identifier topic.

  • Unit of Use DI

Local acceptance record

Links packing evidence to the decision.

  • Lot identifier
  • Artwork revision
  • Packed Package DI
  • Acceptance decision

Local shipping record

Transport reference, separately controlled.

  • Shipping container identifier
  • Dispatch reference
Compare GUDID identifier fields with local acceptance and transport records; local field names are not FDA submission attributes.

03US FDA scope and authority

This regulatory discussion is limited to US medical devices. Do not extend the FDA package-record model to pharmaceutical, food, supplement or chemical packaging, or treat it as a complete account of another device jurisdiction. The broader UDI overview provides context beyond this package-specific assessment.

For US medical devices, 21 CFR 830.50(a) states: “Whenever you make a change to a device that is required to bear a unique device identifier (UDI) on its label, and the change results in a new version or model, you must assign a new device identifier to the new version or model.” 21 CFR 830.50(b) adds: “Whenever you create a new device package, you must assign a new device identifier to the new device package.” Neither provision says that every artwork revision triggers a new identifier. As a practical review method, keep the version/model assessment separate from the package-configuration assessment and record what changed in each, rather than using a single undifferentiated label-change decision.

For US medical devices, consult 21 CFR 830.3 for regulatory definitions and 21 CFR 801.20(a)(2) for device-package labeling scope. Check the current text of 21 CFR 830.310 and 21 CFR 830.320 for information and submission scope. These are separate review questions; a packaging assessment should not substitute for checking the applicable regulatory text.

For US medical devices, the FDA GUDID guidance’s package-information example illustrates distinct DIs on individual device packages, boxes and cartons. This is the guidance’s explanation of a nested packaging arrangement, not a quotation from the regulation.

The packaging reconciliation, approval roles and fictional acceptance form used later are local quality controls, not a prescribed FDA form. Their practical purpose is to connect the assessed configuration to approved labeling and the package record, then document a human decision. An organization can adapt the form and role names while retaining that decision trail.

04How the GUDID package fields fit together

For US medical devices, FDA’s GUDID guidance, a) Package Information in GUDID explains that package information belongs within the Primary DI record. For US medical devices, package configurations inherit base-package attribute values rather than needing separate DI records; package-specific entries describe each configuration within that record. See the broader GUDID record structure for context beyond these packaging fields.

For US medical devices, FDA’s guidance defines Contains DI Package as “DI for the lower level package configuration contained within that particular package configuration (what is the DI for the package inside this package?).” For US medical devices, this relationship allows a case to reference the box’s Package DI, while the box references the Primary DI. The hierarchy therefore describes containment relationships, not merely a collection of identifiers attached to the same product.

For US medical devices, FDA’s guidance describes Quantity per Package as “number of packages contained within the particular package configuration with a unique DI (how many packages are inside this package?).” Its counting unit is the package identified by Contains DI Package: boxes for a case containing boxes, rather than automatically individual devices. For US medical devices, the guidance distinguishes Device Count as the number of medical devices in the base package. Multiplying quantities through the hierarchy can establish a total device count, but that calculated total is not a substitute for the immediate-child quantity.

For US medical devices, FDA’s guidance describes Package Type as “optional text to describe the outer packaging of the product (e.g., box, carton) and enables users to understand higher-level packaging configurations.” A practical review uses that description to help interpret the record, while checking containment through the linked DI and quantity rather than the packaging name alone.

For US medical devices, FDA’s guidance says Package Discontinue Date “indicates the date a particular package configuration is discontinued by the labeler.” For US medical devices, its Package Status explanation is “indicates whether the package configuration is in commercial distribution as defined under 21 CFR 807.3(b); auto-populated by the system based on Package Discontinue Date:”

For US medical devices, FDA’s guidance states the future-or-blank branch exactly: “If Package Discontinue Date > today (i.e., a date in the future) or null, then Package Status = “In Commercial Distribution””. For US medical devices, the guidance describes the today-or-past branch as producing “Not In Commercial Distribution”.

Keep this distribution status separate from the local packaging-acceptance disposition. A practical acceptance record documents whether the inspected packaging matches the applicable approved configuration; it does not treat the GUDID status as an approval of the inspected lot.

05From proposed package change to controlled use

A commonly useful change-control workflow connects the proposed package configuration to the evidence needed for controlled use. The sequence below is a practical coordination model, not a prescribed regulatory workflow; responsibilities and authorization routes depend on the organization.

  1. Characterize the proposal. Describe the current and proposed configurations, their contents, package levels and affected products. Identify what changes and what remains unchanged so reviewers assess a defined configuration rather than an informal request to update a label.
  2. Assess identifier impact. Record the identifier decision and its rationale against the proposed configuration. Distinguish a decision to assign an identifier from the later decision to make that configuration available to packaging operations.
  3. Approve specifications and artwork. Link the package specification and corresponding artwork revisions to the assessed configuration. Reviewers commonly check that the approved documents describe the same physical contents and identifier relationship before progressing the change.
  4. Reconcile master data. Compare the approved configuration with the packaging master and applicable GUDID package information. Record discrepancies, their resolution and the references reviewed, rather than treating completion of a data-entry task as evidence of agreement.
  5. Authorize operational use. Name the responsible approver and define the effective revision for packaging operations. Address remaining materials and work already in progress explicitly, so operators can determine which approved configuration applies to a particular packaging activity.
  6. Preserve superseded evidence. Retain the earlier configuration, artwork references and decision history alongside their replacements. Record the disposition of obsolete materials and the retirement decision without overwriting the evidence needed to interpret earlier packaging records.

Keep identifier assignment, artwork revision, operational effective revision and package retirement as separate decisions in the local record. A shared change record can link them without assuming their milestones are interchangeable. For each decision, a useful record identifies its scope, owner, supporting references and disposition. This separation lets a reviewer reconstruct what was approved, what was authorized for use and what was subsequently retired without inferring one event from another.

06Fictional case: changing the case configuration

Assume a fictional medical-device labeler uses BASE, BOX, CASE-OLD and CASE-NEW as mnemonic identifiers in this example. They are not usable issuing-agency codes; actual identifier structure belongs to the UDI framework. The base package, identified by Primary DI BASE, contains one device. All package quantities below count immediate-child packages, not flattened device totals.

Package DIContains DI PackageQuantity per PackagePackage TypePackage Discontinue Date
BOXBASE30BoxBlank
CASE-OLDBOX8CaseD
CASE-NEWBOX12CaseBlank

The proposed change replaces the case containing 8 boxes with a case containing 12 boxes. In the completed fictional change assessment, the reviewer identifies a replacement case configuration and approves assignment of CASE-NEW. BASE and BOX remain unchanged: neither the individual device package nor the box configuration is revised. CASE-NEW therefore points to BOX, not BASE.

D is the symbolic approved retirement date for CASE-OLD, not a calendar date or a submission deadline. The review is completed after D. The retained package record shows D as CASE-OLD’s Package Discontinue Date; CASE-NEW has no discontinue date in this example. The reviewer applies the package-status logic covered above to those entries.

The approved change record preserves both case configurations rather than overwriting the old row with the new quantity. It links each configuration to its approved artwork and retains the former case relationship for reconciliation of a lot packed before the effective revision. That lot remains labeled CASE-OLD and is carried into the packaging-acceptance review as an identified historical configuration, not silently converted to CASE-NEW.

A variable-load outer shipping carton is recorded separately as a transport object. Following the shipping boundary established above, it has no Package DI in this fictional hierarchy. The completed configuration decision is to approve CASE-NEW for the replacement case, retain CASE-OLD with its retirement date and historical evidence, and leave BASE and BOX unchanged. Packaging acceptance then checks the actual packed material against that decision.

07The completed packaging-acceptance record

For US medical devices, FDA’s GUDID guidance, Appendix D recommends that submitted attribute values match corresponding values on the package or label. The reconciliation below compares the applicable approved labeling with the package record; it does not replace artwork proof approval.

Fictional record assumptions: BASE, BOX, CASE-OLD and CASE-NEW are identifier aliases, not valid issuing-agency identifiers. Each box contains 30 base packages. D is the effective revision date. The case changes from 8 to 12 boxes; the base package and box remain unchanged. The reviewer completes this record after D, using retained packing records, approved artwork and the corresponding GUDID record.

Primary DIRelevant identifierContains DI PackageChild quantityPackage levelApproved-artwork comparisonGUDID comparison and result
BASEBASENot applicableNot applicableBaseBase artwork identifies BASE; unchanged.Primary DI BASE agrees. Accepted.
BASEBOXBASE30 base packagesBoxBox artwork identifies BOX and 30 base packages.BOX entry contains BASE, quantity 30. Accepted.
BASECASE-OLDBOX8 boxesPrior caseRetained old case artwork identifies CASE-OLD and 8 boxes.CASE-OLD entry contains BOX, quantity 8; Package Discontinue Date D. Historical match accepted.
BASECASE-NEWBOX12 boxesReplacement caseNew case artwork identifies CASE-NEW and 12 boxes.CASE-NEW entry contains BOX, quantity 12. New configuration accepted.

Legacy-lot disposition: the retained packing and acceptance records establish that the legacy lot was packed and accepted under the prior revision before D. The lot had already entered distribution before D. Its packing record identifies CASE-OLD, eight BOX packages per case and the applicable old artwork revision. Those values agree with the CASE-OLD entry. The reviewer accepts this historical reconciliation and preserves the lot’s original labeling; the new case artwork is not its acceptance reference. This disposition is not authorization for further distribution of the discontinued configuration.

Completed decision: the designated human reviewer records acceptance of the legacy-lot reconciliation and confirms CASE-NEW against its approved artwork, packing specification and GUDID evidence. The reviewer authorizes CASE-NEW for the example’s controlled use and closes the package-change record. The recorded rationale is agreement of the Primary DI association, package identifier, contained identifier, child quantity and package level with the applicable revision. The closure entry retains the evidence references and reviewer sign-off, making the historical acceptance and new-configuration authorization separately traceable.

Completed fictional packaging-acceptance reconciliation
  1. 1
    Base acceptedBASE; Device Count 1; base-level artwork and GUDID identity match.
  2. 2
    Box acceptedBOX contains BASE; quantity 30; box-level artwork and GUDID entry match.
  3. 3
    Prior case reconciledCASE-OLD contains BOX; quantity 8; prior case artwork and retained GUDID configuration match.
  4. 4
    Replacement case acceptedCASE-NEW contains BOX; quantity 12; revised case artwork and GUDID entry match.
  5. 5
    Retirement recordedCASE-OLD: Package Discontinue Date D; Package Status Not In Commercial Distribution.
  6. 6
    Legacy lot reconciledHistorical packing evidence matches CASE-OLD and prior artwork; original labeling remains recorded.
  7. 7
    Decision closedVariable-load shipping carton has no Package DI. Human reviewer accepts reconciliation and authorizes the replacement configuration.
All package entries belong to Primary DI BASE. Quantities count immediate children. D is the approved retirement date; review occurs afterward.

08A wording-only revision assessed separately

In a separate fictional assessment, a wording correction is proposed for existing package artwork. The stated assumptions are unchanged device version/model, package identity, contained identifier, child quantity and package level. No production-label wording is reproduced here; the correction does not alter the package description or its configuration.

The reviewer compares the previous approved artwork with the revised proof and records the corrected text location in the change-control assessment. The comparison records that the Primary DI association, existing Package DI, Contains DI Package value, Quantity per Package and Package Type remain unchanged. It also confirms that the revised proof still describes the same package level and contents as the approved configuration.

The reviewer uses the change-trigger assessment described in the regulatory-scope section above. The decision rests on the documented comparison, not merely on the request being described as a wording correction.

Completed disposition: the fictional revision retains its existing Package DI and receives its own artwork approval. The assessment links the previous artwork, approved revised proof, unchanged configuration fields and reviewer approval. This closes the artwork decision without changing the package hierarchy. It is an outcome under the stated assumptions, not a conclusion that every wording change is identifier-neutral.

09Moving package data without losing the hierarchy

A practical handoff connects the approved package configuration to each downstream use without treating all records as interchangeable. Package-master data describes the intended configuration; approved artwork controls its label presentation; label-generation inputs select the values to print; packing evidence records what was used; and GUDID submission records document the information transmitted. Keep configuration and revision references with each transfer so reviewers can compare the same package across these records.

Preserve the immediate child’s identifier, the child quantity and its unit together. A count expressed as boxes is not interchangeable with a count expressed as base packages. Document the mapping explicitly rather than relying on a destination field named quantity. When reviewing barcode content, use GS1-128 label interpretation where that carrier applies; do not assume every Package DI uses it. Keep production-level parent-child evidence within the separate serialization and aggregation review.

Recover discrepancies through a local exception route

For a wrong contained DI, a quantity transferred in the wrong unit, obsolete artwork or a failed handoff, use a documented local route:

  1. Contain affected local use, including label selection or packing activity where relevant.
  2. Identify the authoritative approved configuration and determine which downstream records differ.
  3. Correct each affected record through its applicable control process, retaining the reason and authorization.
  4. Repeat the comparison against the approved configuration before authorizing resumed use.

Do not use a submission receipt as a substitute for checking the printed label and its approved artwork. Useful closure evidence includes the discrepancy description, affected configuration and lots, corrected values, applicable artwork revision, resubmission or reconciliation reference where relevant, and human disposition. Record the scope of that disposition explicitly: which records were corrected, which packaging use was accepted and whether any affected material remains contained.

10Failures that a successful scan can miss

Barcode verification addresses symbol quality; acceptance also involves a separate semantic comparison of decoded identity, package level and approved configuration. A readable symbol is one item of evidence, not the completed acceptance decision. The following are illustrative failure modes, not statements about incident frequency.

  • Valid identifier, wrong level: a box DI selected for a case can decode correctly while identifying the wrong configuration. A local preventive control is level-specific identifier selection, followed by comparison with the package actually being accepted.
  • New case, retired child: a new case record can point to an obsolete box configuration even when the case DI is correct. Resolve the child identifier to its controlled configuration and confirm that it is the intended child for this revision.
  • Superseded artwork: a label can match an obsolete proof exactly. Compare against the artwork revision applicable to the packing event, rather than whichever proof is easiest to retrieve.
  • Rewritten history: a master-data update can replace the configuration displayed for an earlier lot. Preserve the original lot record, including the identifiers, quantities and artwork revision used, separately from subsequent master-data changes.

These are manufacturer-defined preventive checks, not additional GUDID field rules. Where a discrepancy remains, use the recovery route covered above rather than treating another successful scan as resolution.

11A review checklist with a clear stopping point

Use this local review aid to close a packaging assessment, not as an FDA-prescribed checklist. The completed case above illustrates the evidence trail; review its recorded decision rather than copying its configuration values.

  • Scope and ownership: identify the affected device, package levels, assessment boundary and responsible reviewers.
  • Configuration identity: confirm the approved Primary DI and applicable Package DI against the configuration being accepted.
  • Child relationship: resolve each Contains DI Package reference to the intended lower-level configuration.
  • Quantity unit: confirm that the recorded count refers to the identified child package, not a different packaging level.
  • Artwork: identify the applicable approved revision and reconcile its identifiers and package description.
  • GUDID comparison: link the compared record and document agreement or explain each difference.
  • Historical lots: identify affected earlier lots and reference the disposition supporting their labeling treatment.
  • Discrepancy closure: link each discrepancy to its resolution and supporting review.
  • Human authorization: record the decision, responsible approver and scope of acceptance.

Retain applicable revisions and decision references through document control. Completion means an explicit recorded disposition supported by linked evidence—not merely an empty task queue. If acceptance is withheld, record that disposition and the unresolved basis rather than implying approval.

Frequently asked questions

Q.What does a Package DI identify after an individual device has been removed from that package?+

For US medical devices, FDA’s GUDID guidance describes Package DI as the identifier for a particular package configuration. Removing a device does not turn that identifier into an identifier for the removed item. In practical traceability records, retain the source-package association without presenting the Package DI as an individual-device identifier. For identifying a device at its point of use, consider the separate role of a Unit of Use DI.

Q.Can sibling package configurations under the same Primary DI contain different lower-level Package DIs?+

For US medical devices, FDA’s GUDID guidance describes Contains DI Package as the DI for the lower-level configuration inside the particular package. Review each sibling’s parent-child relationship separately rather than assuming a shared child identifier. A common Primary DI is not, by itself, evidence that the immediate contents match. Trace each proposed branch to its approved configuration, and check applicable GUDID rules before treating a proposed hierarchy as acceptable.

Q.How should a reviewer investigate a quantity that matches the total device count but not the number of immediately contained packages?+

Start by writing the unit beside each quantity: individual devices, base packages, or intermediate packages. Then identify the immediate child configuration and reconstruct the physical packing arrangement from the approved specification and packing evidence. A matching total device count can conceal a mistaken hierarchy level. Record the discrepancy as a unit-and-relationship question, not simply an arithmetic error. Use serialization aggregation records as supporting evidence where available, rather than as a substitute for the approved configuration.

Q.Can Package Type alone establish that two configurations are the same?+

No practical acceptance decision should rest on a packaging description alone. Compare the configuration identifiers, immediate child identifiers, quantities with their units, and applicable approved labeling. Similar descriptions can conceal different contents, while different local descriptions may refer to equivalent physical arrangements. Document the comparison and resolve ambiguous terminology through change control. Treat the description as a useful navigation aid, not as conclusive evidence that identifier assignments or package relationships agree.

Q.How does Package Discontinue Date differ from an expiry date or a date governed by device-label date formatting?+

In a packaging review, keep configuration discontinuation, product expiry, and printed-date presentation as separate questions. Do not use a Package Discontinue Date as evidence that a particular lot has expired, or use an expiry date to infer when a package configuration stopped being used. Investigate each date against its own approved record and purpose. For legacy stock, establish the actual packing history and applicable configuration before deciding whether its labeling is acceptable.

Q.Does assigning a Package DI resolve a separate UDI direct-marking question?+

No. For US medical devices, FDA’s GUDID guidance describes Package DI as identifying a package configuration and Direct Marking DI as an identifier permanently marked on the device. A packaging identifier therefore does not answer the separate device-marking assessment. Keep that assessment distinct in the review record, with its own rationale and approval. The broader UDI framework provides context, but the packaging decision should not be recorded as resolving both questions.

Q.What evidence supports a retrospective review when the original artwork is no longer the current revision?+

Build a historical evidence set around the configuration actually packed: the approved artwork revision then in effect, its approval and effective-change records, the packaging specification, executed packing records, and retained label specimens or attributable images where available. Compare those materials with the relevant historical package data rather than silently substituting today’s values. Record gaps and their effect on confidence. This approach distinguishes evidence of the original operation from later administrative reconstruction.

Q.How should a reviewer distinguish a locally completed correction from confirmation that the corresponding GUDID entry and labeling agree?+

Use separate completion statements. A local correction means the identified internal record or artwork issue has been addressed; reconciliation means the reviewer has compared the relevant GUDID information, approved labeling, and package configuration and documented their agreement. Record the identifiers, revisions, comparison date, reviewer, and any unresolved differences. Link the decision to the affected GUDID record, and do not treat a closed internal task as evidence that external information also agrees.

Primary sources

  • FDA Guidance: Global Unique Device Identification Database (GUDID), Dec 17 2024
Software that covers Package Device Identifier
V5 Ultimate Medical Device MES
Device history records built from signed steps at the workstation: component lots, configured step order, inspections, UDI and…
V5 Ultimate for EU MDR
V5 assembles it as one file that a Notified Body auditor can navigate in an hour.
Talk to us about Package Device Identifier

Want to see how Package Device Identifier could fit into your own records and workflows? Explore the related V5 pages or talk to our team about what applies to your operation.

Start free
Back to glossary
Where this term comes up
Medical Devices
Related terms
  • → GUDID
  • → UDI
  • → Unit of Use DI
  • → UDI-DI vs UDI-PI

Next Step

Try V5 with your own records, or ask a question first. Ask V5 opens with an editable question; nothing is sent until you choose to.

Start your free trial Browse All Features

Showing the site for the United States. Local spelling, dates and prices are applied automatically; change the language at the top of the page.

V5 Ultimate
Ultimate

Warehouse, quality and manufacturing software for regulated operations.

ProductIndustriesPricingResourcesSecurity & TrustCompanyLegal Centre

© S.G. Systems, LLC