V5 Ultimate
Ultimate
PricingResourcesCompany
English (original)العربيةDeutschΕλληνικάEspañolFrançaisItalianoעברית日本語한국어NederlandsPolskiPortuguêsSvenska
Talk to us Log in Start free trial
Food & Beverage
  • Bakery & Confectionery
  • Food Processing
  • Ingredients & Dry Mixes
  • Sausage & Meat Products
  • Produce Packing
  • Pet Food & Pet Supplements
  • Dairy & Chilled Foods
  • Beverages & Liquid Manufacturing
  • Infant Formula
Pharma & Life Sciences
  • Radiopharmaceuticals
  • Pharmaceutical
  • Medical Devices
  • Veterinary Pharmaceuticals
  • Blood & Tissue
  • Diagnostics & IVD Kits
  • Reference Materials & Standards
  • OTC Topical Creams & Gels
Supplements & Personal Care
  • Dietary Supplements
  • Cosmetics & Personal Care
  • Cannabis & Hemp Manufacturing
  • Fragrances & Perfumery
  • Soaps & Personal Hygiene
  • Botanical Extracts & Essential Oils
Chemicals & Materials
  • Plastics & Resins
  • Agricultural Chemicals
  • Specialty & Industrial Chemicals
  • Printing Inks, Pigments & Construction Chemicals
  • Lubricants & Metalworking Fluids
  • Coatings, Adhesives & Sealants
Other Manufacturing
  • Consumer Products
  • Electronics & Electrical Assembly
  • Textiles & Nonwoven
  • Contract Manufacturing & Co-Packing
  • Packaging & Food-Contact Materials
  • Regulated Warehousing & Distribution
Explore all industries
  • Warehouse & TraceabilityReceive, store, pick and trace
  • Production & PlanningPlan jobs and guide production
  • Quality & LaboratoryTest, investigate and review
  • Documents & TrainingControl procedures and qualifications
  • Equipment & PerformanceMaintain assets and measure losses
  • Orders & IntegrationsConnect customers, suppliers and systems
  • Outputs & InsightsReports, KPIs and label design
Why V5? Product & Features
Why V5?Product & Features
  • Warehouse & TraceabilityReceive, store, pick and trace
  • Production & PlanningPlan jobs and guide production
  • Quality & LaboratoryTest, investigate and review
  • Documents & TrainingControl procedures and qualifications
  • Equipment & PerformanceMaintain assets and measure losses
  • Orders & IntegrationsConnect customers, suppliers and systems
  • Outputs & InsightsReports, KPIs and label design
Explore all industries
    • Bakery & Confectionery
    • Food Processing
    • Ingredients & Dry Mixes
    • Sausage & Meat Products
    • Produce Packing
    • Pet Food & Pet Supplements
    • Dairy & Chilled Foods
    • Beverages & Liquid Manufacturing
    • Infant Formula
    • Radiopharmaceuticals
    • Pharmaceutical
    • Medical Devices
    • Veterinary Pharmaceuticals
    • Blood & Tissue
    • Diagnostics & IVD Kits
    • Reference Materials & Standards
    • OTC Topical Creams & Gels
    • Dietary Supplements
    • Cosmetics & Personal Care
    • Cannabis & Hemp Manufacturing
    • Fragrances & Perfumery
    • Soaps & Personal Hygiene
    • Botanical Extracts & Essential Oils
    • Plastics & Resins
    • Agricultural Chemicals
    • Specialty & Industrial Chemicals
    • Printing Inks, Pigments & Construction Chemicals
    • Lubricants & Metalworking Fluids
    • Coatings, Adhesives & Sealants
    • Consumer Products
    • Electronics & Electrical Assembly
    • Textiles & Nonwoven
    • Contract Manufacturing & Co-Packing
    • Packaging & Food-Contact Materials
    • Regulated Warehousing & Distribution
PricingResourcesCompany
Start free trial Log in Talk to us
HomeGlossaryInvestigator Agreement
Compliance · The complete guide

Investigator Agreement

In short

Investigator Agreement is the signed agreement a US device sponsor must obtain from each participating investigator under 21 CFR 812.43(c), covering the investigator's CV, relevant experience, any terminated research and commitments on conduct, supervision, consent and financial disclosure.

4,169 words · ~19 min read
A physician investigator signs an agreement while a sponsor clinical research associate checks a site readiness list on a tablet beside a sealed device box.
The signed investigator agreement is one site-readiness record, separate from the plan, IRB approval and shipment decision.
On this page
  1. 01Investigator Agreement
  2. 02Check the agreement’s required contents element by element
  3. 03Separate the agreement from plans, approvals, forms and contracts
  4. 04Review investigator readiness before making a shipment decision
  5. 05Link signed versions to the evidence actually reviewed
  6. 06Reconcile document, investigator and shipment handoffs
  7. 07Apply the controls to three fictional sponsor cases
  8. 08Match common evidence failures to a specific review control
  9. 09Retain the agreement against the correct retention endpoint
  10. 10Finish with an accountable review and follow-up checklist
On this page · 10 sections
  1. 1Investigator Agreement
  2. 2Check the agreement’s required contents element by element
  3. 3Separate the agreement from plans, approvals, forms and contracts
  4. 4Review investigator readiness before making a shipment decision
  5. 5Link signed versions to the evidence actually reviewed
  6. 6Reconcile document, investigator and shipment handoffs
  7. 7Apply the controls to three fictional sponsor cases
  8. 8Match common evidence failures to a specific review control
  9. 9Retain the agreement against the correct retention endpoint
  10. 10Finish with an accountable review and follow-up checklist
AI · Explain it for MY operation

How does Investigator Agreement apply to your shop floor?

Pick your industry and scale — Ask V5 rewrites the definition in your context, gives a worked example, and shows what V5 does on day one.

Your scale

01Investigator Agreement

Investigator Agreement is a signed document recording an investigator’s commitments for participation in a US FDA-regulated medical-device investigation.

What the agreement establishes—and the limits of this article

IDE investigator agreement and 21 CFR 812.43(c) signed agreement are search aliases for this document, not separate document classes.

For US medical-device investigations subject to 21 CFR 812.43(c), the sponsor must obtain a signed agreement from each participating investigator. For those investigations, 21 CFR 812.43(c)(4) requires a statement of the investigator’s commitment. Treat the agreement as a participation record, rather than using its signature as a substitute for an approval or commercial contract.

This article separates binding US device regulations from FDA application guidance and illustrative sponsor procedures. A suggested review sequence or fictional shipment hold is a sponsor-control example, not an additional FDA requirement. Responsible sponsor personnel decide investigation classification, regulatory applicability and operational disposition.

Check the current text of 21 CFR 812.25 for the investigational-plan scope applicable to US device investigations. For the related operational task of tracking investigational devices, see investigational device accountability. Keep the agreement review focused on the investigator and supporting evidence; later sections address document boundaries, shipment decisions and retention.

Other markets are outside this article’s scope. It provides no clinical decisions, treatment recommendations or study-design advice and is not legal advice.

02Check the agreement’s required contents element by element

For applicable US medical-device investigations, 21 CFR 812.43(c) requires the sponsor to obtain a signed agreement from each participating investigator containing the specified elements. A useful content review separates background information, conditional explanations and commitments. Checking only for a signature leaves unanswered whether the agreement covers the required substance.

CV, relevant experience and terminated research

For applicable US medical-device investigations, 21 CFR 812.43(c)(1)–(2) requires the investigator’s curriculum vitae and, where applicable, a statement of relevant experience, including its dates, location, extent and type. Preserve the distinction: the CV is an unconditional element; the experience statement carries the qualifier where applicable. In a sponsor’s review worksheet, consider each experience detail separately rather than treating a job title as an answer to all of them.

For applicable US medical-device investigations, 21 CFR 812.43(c)(3) requires an explanation of the circumstances leading to termination if the investigator was involved in an investigation or other research that was terminated. The review question is conditional: does that circumstance apply, and, if so, is the explanation present? As a review practice, do not infer misconduct, disqualification or a particular outcome from termination alone; assess the explanation rather than substituting an assumption.

Conduct, supervision and informed consent

For applicable US medical-device investigations, the conduct commitment under 21 CFR 812.43(c)(4)(i) is: “Conduct the investigation in accordance with the agreement, the investigational plan, this part and other applicable FDA regulations, and conditions of approval imposed by the reviewing IRB or FDA;” A sponsor’s content check should preserve that full scope, including the wording IRB or FDA, rather than reducing the commitment to following the plan alone.

For applicable US medical-device investigations, 21 CFR 812.43(c)(4)(ii) requires the investigator’s commitment to supervise all testing of the device involving human subjects. For the same US device scope, 21 CFR 812.43(c)(4)(iii) requires the commitment to ensure that requirements for obtaining informed consent are met. Review these as distinct commitments, without turning the agreement review into staffing instructions or treating the investigator’s signature as a subject’s consent.

Financial information and its update commitment

For applicable US medical-device investigations, 21 CFR 812.43(c)(5) requires sufficient accurate financial disclosure information to allow the sponsor to submit a complete and accurate certification or disclosure statement. Under that same provision, the US device sponsor must also obtain the clinical investigator’s commitment to promptly update the information if relevant changes occur during the investigation and for 1 year following completion of the study. These are separate content checks: initial information supports the statement; the commitment addresses subsequent relevant changes.

Use a worksheet without inventing extra requirements

An illustrative sponsor worksheet can use the following statuses. They are review aids, not a prescribed FDA form.

Review statusWhat the reviewer records
PresentIdentify the document or passage addressing the element; distinguish presence from acceptance.
Clarification neededDescribe the missing or ambiguous content and assign a person to resolve it.
Conditional applicabilityRecord whether the experience or termination condition applies, with the basis for that assessment.

Keep sponsor choices about attachments, document currency and review routing in separate worksheet fields, labelled as sponsor procedure. A reviewer can then distinguish a missing regulatory element from an unresolved internal acceptance question. Keep this content review separate from investigational device accountability: inventory reconciliation answers a different operational question.

03Separate the agreement from plans, approvals, forms and contracts

Use each document to answer a different review question. The agreement’s reference to the investigational plan, covered above, connects the investigator’s commitments to the investigation’s governing documents; it does not make the agreement itself the plan. The following comparison is an operational document map, not a determination of contract sufficiency.

DocumentQuestion it addressesEvidence to inspectBoundary to preserve
Investigator AgreementWhat commitments has this investigator signed?Executed agreement, referenced plan and supporting investigator information.Apply the content test above, not merely a signature check.
Investigational planWhat investigation do the commitments concern?Identified plan and its protocol information.A description of the investigation is not the investigator’s signed commitment.
IRB action or approval recordWhat action did the IRB document?Action record identifying the investigation and the decision communicated.Keep the IRB’s action distinct from the investigator’s agreement.
Form FDA 1572Is this form appropriate for the applicable FDA framework?Current FDA instructions concerning product scope.Do not use the form’s presence as a shortcut around the device-agreement content test.
CTA or budget contractWhat commercial arrangements have the parties accepted?Signed terms addressing payment, services and negotiated responsibilities.A contract title does not establish which investigator commitments it contains.

For US significant-risk medical-device IDE applications, FDA’s IDE Application guidance, investigational-plan protocol bullet, lists a written protocol describing the methodology and an analysis demonstrating its scientific soundness. This maps application information to the plan; it is not an additional quotation of regulatory text.

For US significant-risk medical-device IDE applications, the guidance’s agreement example item lists an example agreement and investigators’ names and addresses. For those US device applications, its separate IRB-action item lists certification of IRB action when available. These are distinct application items, not interchangeable documents.

FDA's final Statement of Investigator guidance, question 8, explains that Form FDA 1572 is required for investigational drug and biologic studies conducted under an IND and is not applicable to investigational device studies. Device sponsors obtain the signed investigator agreement under 812.43(c) instead. This is the drug-IND versus device distinction, not a choice between interchangeable templates. In ordinary industry usage, CTAs and budgets address commercial arrangements. Inspect the actual signed commitments rather than inferring their substance from a contract title.

Outside the United States, device clinical investigations are commonly organised around ISO 14155 and its clinical investigation plan; that framework is summarised separately under ISO 14155 clinical investigation and is not a substitute for checking 812.43(c) in a US IDE study.

04Review investigator readiness before making a shipment decision

For applicable US medical-device investigations, 21 CFR 812.43(a) requires the sponsor to select investigators qualified by training and experience to investigate the device. A signature should not be treated as a completed qualification assessment: the sponsor’s reviewer should document why the investigator’s qualifications are appropriate for the device.

For applicable US medical-device investigations, 21 CFR 812.43(b) requires the sponsor to ship investigational devices only to qualified investigators participating in the investigation. Use that restriction as a shipment eligibility rule, not as a complete site-activation checklist.

For US significant-risk medical-device IDE applications, FDA’s IDE Application guidance, Required Elements, item 06 describes an application certification that all investigators have signed the agreement, the investigator list includes everyone participating, and new investigators will sign before being added to the study. That application-level certification is distinct from each investigator’s signed agreement; review the certification against the underlying agreements and participation list rather than treating it as their replacement.

Illustrative sponsor decision workflow

The following states are a proposed sponsor operating model, not regulatory terminology or a universal activation rule. Assign named human reviewers and define their authority in the sponsor procedure.

Document completeness — Document reviewer checks the signed agreement and supporting qualification evidence against the content review described above; records gaps and the reviewed versions. ↓ Participation readiness — Sponsor-designated investigator reviewer assesses training and experience for the device, reconciles the investigator’s participation status, and records the basis for acceptance. ↓ Shipment authorization — Authorized sponsor approver checks the intended recipient against the accepted investigator and current participation record, resolves shipment-relevant holds, and issues a documented instruction to logistics.

Under this model, unresolved issues remain assigned to an owner, with the affected transition held pending an explicit reviewer decision. Avoid a single ready flag that conceals whether a concern affects documents, participation or shipment. Attach the decision record to the shipment instruction: investigator identity, investigation, evidence references, reviewer, decision date and any restrictions. Logistics should refer discrepancies back to the authorizer rather than infer clearance from a signature. Link the resulting dispatch record to investigational device accountability so the authorized decision and physical movement can be reconciled.

Sponsor review workflow
  1. 1
    Define applicabilityIdentify the investigation, participating investigator and responsible sponsor reviewer.
  2. 2
    Assess qualificationsReview qualifications evidence against the device and proposed participation.
  3. 3
    Complete agreementAssemble applicable content and obtain the investigator’s signature.
  4. 4
    Reconcile documentsResolve agreement, plan and approval-condition references before readiness review.
  5. 5
    Record readinessDocument outstanding issues and the reviewer’s separate shipment decision.
  6. 6
    Control shipmentConfirm investigator identity and participation against the shipment instruction.
  7. 7
    Maintain historyManage changes, disclosure updates, exceptions and eventual retention review.
Illustrative sponsor procedure; each transition records a human decision and linked evidence.

05Link signed versions to the evidence actually reviewed

For a US device sponsor, an evidence snapshot can preserve the basis of a human reviewer’s readiness decision. The following structure is an illustrative document-control practice, not an FDA-mandated schema. Its purpose is to let another reviewer reconstruct which records supported the decision without assuming that today’s current documents were available then.

Illustrative evidence map: investigator identity + site identity → signed agreement version + signature record → qualifications evidence versions + investigational-plan reference + applicable approval-condition reference → reviewer identity, decision, date and rationale.

Give each supporting record its own identifier and version or date. The agreement’s version does not establish the CV’s version, the plan’s revision or the approval correspondence considered. A snapshot can reference controlled records rather than duplicate every file, provided those references resolve to the historical versions reviewed. Record any unresolved item and the reviewer’s disposition alongside that snapshot. Keep later arrivals separately identifiable, with their receipt dates and any subsequent review decision.

  • Supersession designates a successor for current use while preserving the earlier signed record and its decision context. A linked history, analogous to a supersession log, can show that relationship.
  • Correction addresses an identified error. Record what changed, why, who authorised it and how the correction relates to the signed record; avoid silently overwriting it.
  • Acknowledgement records a person’s recognition of a specified document or change. Identify its subject and version rather than treating it as an unspecified replacement agreement.

In the later fictional case, the sponsor SOP calls for re-acknowledgement after the specified plan revision. That trigger belongs to the fictional procedure; it should not be read as a universal legal rule requiring a new agreement after every revision.

For financial disclosure, a proposed information-handling choice is to link a restricted record and show its review status. Define access scopes by review role rather than distributing sensitive details throughout the readiness file.

Agreement evidence relationships

Investigator

Identifies the person and participation context.

  • investigator_id
  • site_id
  • qualifications_review_ref
  • participation_status

Signed agreement

Preserves the signed version and retention linkage.

  • agreement_id
  • investigator_id
  • agreement_version
  • signed_at
  • signed_record_ref
  • retention_review_ref

Evidence reference

Links supporting documents without conflating their versions.

  • evidence_id
  • evidence_type
  • document_version
  • plan_revision_ref
  • access_scope

Readiness review

Records the reviewer’s decision and evidence basis.

  • review_id
  • investigator_id
  • decision
  • reviewer_id
  • evidence_snapshot_ref

Shipment record

Connects the receiving investigator and device movement.

  • shipment_id
  • consignee_ref
  • device_type
  • quantity
  • shipment_date
  • batch_or_code_mark
Illustrative linked records, not a prescribed schema or an automated release mechanism.

06Reconcile document, investigator and shipment handoffs

A sponsor may reconcile its document repository, investigator roster and shipment records through a manual review or a defined exchange of records. These are proposed operational controls, not a mandated integration architecture; they assume neither automatic integration nor validated software.

Useful reconciliation keys are investigator_id for the person, site_id for the location, agreement_id and document_version for the signed record, review_id for the acceptance decision, and shipment_id for the dispatch. A shared identifier connects records; it does not establish that a reviewer accepted the evidence. Keep the reviewer’s decision, rationale and date linked separately.

For applicable US medical-device investigations, 21 CFR 812.140(b)(2) requires shipment records to include the consignee’s name and address, device type and quantity, shipment date, and batch number or code mark. Map these respectively to recipient details, device identification and amount, dispatch date, and batch/code identification in the shipment record. Keep those fields accessible through shipment_id for investigational device accountability.

  1. Identify the discrepancy and affected records: stale participation status, changed consignee details, an unavailable signed agreement or duplicate investigator identities.
  2. Stop the affected handoff under sponsor procedure and assign an owner. Before shipment, this can mean holding dispatch pending review. After shipment, flag the dispatched consignment and refer further action to responsible personnel rather than treating a hold as a completed remedy.
  3. Obtain corrected evidence. Confirm participation or recipient details, retrieve the signed record, or resolve duplicate identities without erasing their prior associations.
  4. Have the responsible reviewer reassess the earlier decision and document closure, including any remaining restrictions.

Preserve the original discrepancy, correction history and decision trail for audit trail review. Responsible personnel decide disposition; matching identifiers alone cannot close an exception.

07Apply the controls to three fictional sponsor cases

These fictional US device sponsor cases illustrate procedural decisions, not legal advice or predicted outcomes. Each assumes a responsible human reviewer records the evidence considered, the unresolved issue and the disposition. Other markets are outside their scope.

Signed agreement, unresolved CV review

Assume site S-12 has signed agreement v2, but its CV fails the fictional sponsor’s document-currency policy. S-12 and v2 are identifiers. The policy blocks shipment until the supporting-evidence review is resolved. The reviewer records shipment held under that policy while preserving the signed agreement as received. The existing signature and the unresolved CV review remain distinct record statuses.

After receiving an updated CV, the reviewer checks investigator identity, policy currency criteria, relevant qualifications and consistency with the experience information already recorded. An updated document alone does not establish qualification. Resolution evidence includes the CV, any clarification requested and the reviewer’s assessment. The recorded disposition remains held unless the responsible reviewer documents resolution and authorizes removal of this policy hold.

Plan revision awaiting re-acknowledgement

Assume a revised investigational plan triggers re-acknowledgement under the fictional sponsor SOP described above. The discrepancy is an agreement record linked to the superseded plan reference without acknowledgement of the replacement. Following that SOP distinction, the reviewer identifies the revised plan by its controlled identifier and revision, locates the affected signed agreement record and requests the acknowledgement specified by the procedure.

Resolution evidence links the investigator’s acknowledgement to the revised plan and affected agreement without overwriting the earlier relationship. The sponsor records whether the acknowledgement satisfies its procedure and whether any follow-up remains. In this case, the recorded disposition is acknowledgement review pending until that decision is documented.

Receiving-investigator mismatch before shipment

Assume the investigator roster and pending shipment instruction name different receiving investigators, and the device has not shipped. Under the fictional sponsor procedure, operations pauses the instruction rather than choosing whichever record appears newer. The reviewer reconciles identity and participation against the agreement, qualification review and authorized roster, then obtains a corrected instruction or a documented explanation resolving the discrepancy.

Using the shipment rule covered above, the responsible reviewer determines whether the pending instruction can proceed. The recorded disposition identifies the intended investigator, supporting evidence and authorization or continued hold. Linking that decision to investigational device accountability preserves the connection between investigator review and the eventual shipment record.

08Match common evidence failures to a specific review control

Use this proposed diagnostic table after the legal checks described above. These are plausible evidence failures, not measured prevalence. Assign named people to the suggested roles through sponsor procedures; document control supports traceability, not acceptance by itself.

Failure patternEvidence relationship to checkProposed controlHuman decision owner
Unsigned or wrong-investigator agreementCompare signature page, named investigator and participation roster.Obtain the correct signed record; preserve the discrepancy history.Sponsor investigator-review lead: accept identity and execution evidence?
Ambiguous plan-version referenceCompare agreement reference with controlled plan history.Document the intended version and assess any acknowledgement gap.Sponsor study lead: accept the linkage or seek clarification?
Unresolved financial-information updateCompare investigator correspondence with retained disclosure information.Reconcile the update and document its review.Sponsor disclosure reviewer: accept completeness or request follow-up?
Shipment identity mismatchCompare shipment request, consignee and investigator readiness record.Pause the proposed dispatch pending identity reconciliation.Sponsor shipment authorizer: authorize or continue the hold?
Amendment detached from signed predecessorInspect amendment identifiers and original executed agreement.Reconstruct the chain through controlled references.Sponsor agreement owner: accept continuity or obtain corrected execution?

Detection logs the discrepancy; correction repairs the record through change control; acceptance documents the responsible reviewer’s judgment. Keep these actions distinguishable. A completed checklist is an input to review, not a substitute for that decision or a guarantee of compliance.

09Retain the agreement against the correct retention endpoint

For applicable US medical-device investigations, 21 CFR 812.140(b)(3) lists signed investigator agreements, including the financial-disclosure information required to be collected, among sponsor records.

For applicable US medical-device investigations, 21 CFR 812.140(d) requires an investigator or sponsor to maintain the records required by this subpart during the investigation and for 2 years after the later of the specified dates.

For applicable US medical-device investigations under that provision, the endpoints are the date the investigation is terminated or completed and the date records are no longer required to support a premarket approval application, a notice of completion of a product development protocol, a humanitarian device exemption application, a premarket notification submission, or a request for De Novo classification—not automatically the site-closeout date.

Document the disposition decision

As a practical governance control, use a retention review record that identifies:

  • The agreement and financial-disclosure records covered by the review.
  • Both applicable endpoints, their supporting evidence and the rationale for selecting the later date.
  • Unresolved submission-support dependencies, with an owner responsible for obtaining clarification.
  • The authorized human decision to continue retention or approve disposition, including its rationale and approval date.

If an endpoint remains unresolved, record that uncertainty rather than assigning an unsupported destruction date. For electronic archives, assess 21 CFR Part 11 applicability separately from this retention calculation. A scheduled review can prompt a decision; it should not substitute for authorized disposition.

10Finish with an accountable review and follow-up checklist

Use this proposed checklist to close the review, separating completed evidence checks from decisions still awaiting an accountable person.

  • Applicability: name the owner and link the scope determination discussed above; other markets are outside this article's scope.
  • Identity: reconcile the investigator, site and signed agreement.
  • Content: record the reviewer’s conclusion against the required-elements section, with the review date captured as a contemporaneous record.
  • Evidence: link the supporting records and reviewed versions using the version-control approach above.
  • Exceptions: give each unresolved item a proposed owner, next action and linked record; classify it under the sponsor's procedure, which may or may not treat it as a formal deviation.
  • Contract package: identify the exact agreement pages, signer and version when the commitment sits inside a larger contract; route commercial-only amendments to the contract owner.
  • Shipment: name the decision owner and connect the decision to the relevant readiness review.
  • Changes: assign a route for change review, including who evaluates effects on earlier decisions.
  • Retention: identify the retention-review owner and refer to the retention section for the endpoint assessment.

Under this proposed operating model, responsible personnel assess unresolved matters, authorize or withhold the operational action, and document the disposition and its basis. A completed checklist supports that judgment; it does not make it.

Frequently asked questions

Q.Who signs when several participating investigators work at the same site?+

Under 21 CFR 812.43(c), the sponsor obtains a signed agreement from each participating investigator, so the obligation is per investigator rather than per site. For US significant-risk device IDE applications, FDA’s IDE Application guidance describes certification that all participating investigators have signed the agreement. As a sponsor review practice, reconcile the investigator list against actual responsibilities rather than treating the site’s lead investigator as a proxy for everyone. Resolve whether each person is a participating investigator or supporting staff before collecting signatures. Keep the role determination with the agreement index so staff changes do not silently alter the signing population.

Q.What should a reviewer check when the investigator’s signature is electronic?+

As a document-review practice, check the signer’s identity, the recorded signing date, the document version signed, and whether the signature remains associated with that exact record when exported. Review any available signing history for unexplained replacement, cancellation, or modification. A pasted signature image alone does not explain how signing occurred. Route unresolved authenticity questions to the responsible reviewer rather than accepting visual appearance as sufficient evidence. An audit trail review workflow can structure that assessment.

Q.Can Form FDA 1572 replace the device investigator agreement?+

No. The drug-IND versus device distinction and its FDA source are explained in the related-documents section. For a device investigation subject to 21 CFR 812.43(c), obtain the signed device agreement with the required contents. As a practical document-control decision, route an incorrectly supplied 1572 to the sponsor's agreement owner, identify the affected investigator and preserve the correction through document control. Do not merely change the heading on the wrong form.

Q.What clarification should a sponsor seek when an investigator reports terminated research?+

As a qualification-review practice, ask which investigation ended, what the investigator’s role was, who initiated the termination, and the stated reason. Clarify whether the report concerns the whole investigation, the institution’s participation, or the individual’s involvement. Request enough context to distinguish an administrative closure from concerns relevant to the proposed responsibilities, without presuming misconduct. Record unresolved questions and the reviewer’s disposition in the QA process, keeping the assessment factual and limited to investigator qualification.

Q.Does financial disclosure information belong in the IDE application?+

No. For US device investigations, 21 CFR 812.43(c)(5) states that this information shall not be submitted in an IDE application but shall be submitted in any marketing application involving the device. As a records-management practice, keep the financial disclosure material linked to the investigator’s agreement while distinguishing it from the IDE submission package. Use a submission-content review to prevent accidental inclusion; an internal file’s completeness and an application’s contents are separate review decisions.

Q.How should a sponsor reassess the records when an investigator changes institutions?+

Treat the move as a documented reassessment rather than simply replacing an address. As sponsor practice, compare the investigator’s responsibilities, institutional affiliation, agreement references, shipment destination, and supporting qualification information against the proposed arrangement. Identify which records remain applicable and which need replacement or clarification. Preserve the previous institutional association so historical activity stays interpretable. Use change control to assign review owners and record the human decision about continuing participation; the move alone should not silently authorize a new shipment destination.

Q.Can a site be administratively active while its device shipment remains on hold?+

Yes, if the sponsor's procedures distinguish administrative setup from shipment authorization. The worked cases above show why these statuses differ. Administrative tasks can continue within their authorized scope while the shipment decision remains held. Record which activity the status permits, who owns the separate shipment decision and where its current restrictions are recorded; an administrative active label must not be passed to logistics as a shipment instruction.

Q.What should an archive handover preserve so the agreement and its supporting records remain usable?+

As an archive practice, preserve the signed agreement, its attachments, investigator and institution identifiers, version relationships, qualification-review decisions, and links to separately controlled financial disclosure records. Include an index explaining where each record resides, who controls access, and how it can be retrieved after systems or personnel change. Test retrieval and legibility before accepting the handover. Preserve relevant audit trail information alongside electronic records so a future reviewer can distinguish the signed record from later administrative changes.

Primary sources

  • 21 CFR 812.43 Selecting investigators and monitors
  • 21 CFR 812.140 Records
  • FDA IDE Application
  • FDA final Statement of Investigator (Form FDA 1572) guidance, question 8
Talk to us about Investigator Agreement

Want to see how Investigator Agreement could fit into your own records and workflows? Explore the related V5 pages or talk to our team about what applies to your operation.

Start free
Back to glossary
Where this term comes up
Medical Devices
Related terms
  • → Investigational Plan
  • → Significant Risk Device
  • → Investigational Device Accountability
  • → Document control

Next Step

Try V5 with your own records, or ask a question first. Ask V5 opens with an editable question; nothing is sent until you choose to.

Start your free trial Browse All Features

Showing the site for the United States. Local spelling, dates and prices are applied automatically; change the language at the top of the page.

V5 Ultimate
Ultimate

Warehouse, quality and manufacturing software for regulated operations.

ProductIndustriesPricingResourcesSecurity & TrustCompanyLegal Centre

© S.G. Systems, LLC