V5 Ultimate
Ultimate
PricingResourcesCompany
English (original)العربيةDeutschΕλληνικάEspañolFrançaisItalianoעברית日本語한국어NederlandsPolskiPortuguêsSvenska
Talk to us Log in Start free trial
Food & Beverage
  • Bakery & Confectionery
  • Food Processing
  • Ingredients & Dry Mixes
  • Sausage & Meat Products
  • Produce Packing
  • Pet Food & Pet Supplements
  • Dairy & Chilled Foods
  • Beverages & Liquid Manufacturing
  • Infant Formula
Pharma & Life Sciences
  • Radiopharmaceuticals
  • Pharmaceutical
  • Medical Devices
  • Veterinary Pharmaceuticals
  • Blood & Tissue
  • Diagnostics & IVD Kits
  • Reference Materials & Standards
  • OTC Topical Creams & Gels
Supplements & Personal Care
  • Dietary Supplements
  • Cosmetics & Personal Care
  • Cannabis & Hemp Manufacturing
  • Fragrances & Perfumery
  • Soaps & Personal Hygiene
  • Botanical Extracts & Essential Oils
Chemicals & Materials
  • Plastics & Resins
  • Agricultural Chemicals
  • Specialty & Industrial Chemicals
  • Printing Inks, Pigments & Construction Chemicals
  • Lubricants & Metalworking Fluids
  • Coatings, Adhesives & Sealants
Other Manufacturing
  • Consumer Products
  • Electronics & Electrical Assembly
  • Textiles & Nonwoven
  • Contract Manufacturing & Co-Packing
  • Packaging & Food-Contact Materials
  • Regulated Warehousing & Distribution
Explore all industries
  • Warehouse & TraceabilityReceive, store, pick and trace
  • Production & PlanningPlan jobs and guide production
  • Quality & LaboratoryTest, investigate and review
  • Documents & TrainingControl procedures and qualifications
  • Equipment & PerformanceMaintain assets and measure losses
  • Orders & IntegrationsConnect customers, suppliers and systems
  • Outputs & InsightsReports, KPIs and label design
Why V5? Product & Features
Why V5?Product & Features
  • Warehouse & TraceabilityReceive, store, pick and trace
  • Production & PlanningPlan jobs and guide production
  • Quality & LaboratoryTest, investigate and review
  • Documents & TrainingControl procedures and qualifications
  • Equipment & PerformanceMaintain assets and measure losses
  • Orders & IntegrationsConnect customers, suppliers and systems
  • Outputs & InsightsReports, KPIs and label design
Explore all industries
    • Bakery & Confectionery
    • Food Processing
    • Ingredients & Dry Mixes
    • Sausage & Meat Products
    • Produce Packing
    • Pet Food & Pet Supplements
    • Dairy & Chilled Foods
    • Beverages & Liquid Manufacturing
    • Infant Formula
    • Radiopharmaceuticals
    • Pharmaceutical
    • Medical Devices
    • Veterinary Pharmaceuticals
    • Blood & Tissue
    • Diagnostics & IVD Kits
    • Reference Materials & Standards
    • OTC Topical Creams & Gels
    • Dietary Supplements
    • Cosmetics & Personal Care
    • Cannabis & Hemp Manufacturing
    • Fragrances & Perfumery
    • Soaps & Personal Hygiene
    • Botanical Extracts & Essential Oils
    • Plastics & Resins
    • Agricultural Chemicals
    • Specialty & Industrial Chemicals
    • Printing Inks, Pigments & Construction Chemicals
    • Lubricants & Metalworking Fluids
    • Coatings, Adhesives & Sealants
    • Consumer Products
    • Electronics & Electrical Assembly
    • Textiles & Nonwoven
    • Contract Manufacturing & Co-Packing
    • Packaging & Food-Contact Materials
    • Regulated Warehousing & Distribution
PricingResourcesCompany
Start free trial Log in Talk to us
HomeGlossaryPET Laboratory Record
Records · The complete guide

PET Laboratory Record

In short

Understand how US PET drug laboratory records connect test execution, complete evidence, traceable changes, investigations, and a separately documented batch decision.

4,119 words · ~19 min read
A PET quality control analyst in hair cover, mask, safety glasses, lab coat and gloves reviews a chromatogram on a tablet beside an HPLC system and a lead-shielded sample carrier.
A PET laboratory record keeps the original test data, calculations and result against acceptance criteria for each batch tested.
On this page
  1. 01What a PET Laboratory Record documents
  2. 02Laboratory evidence and its neighbouring records
  3. 03The test-record content specified in 212.60(g)
  4. 04Build the record around the test event
  5. 05Correct a transcription without rewriting the test
  6. 06Keep the failed test, investigation, and subsequent test connected
  7. 07Separate test assessment from the batch release decision
  8. 08A fictional QC record completed with a rejection decision
  9. 09Recover missing links without creating replacement history
  10. 10Questions that test whether the record system is usable
On this page · 10 sections
  1. 1What a PET Laboratory Record documents
  2. 2Laboratory evidence and its neighbouring records
  3. 3The test-record content specified in 212.60(g)
  4. 4Build the record around the test event
  5. 5Correct a transcription without rewriting the test
  6. 6Keep the failed test, investigation, and subsequent test connected
  7. 7Separate test assessment from the batch release decision
  8. 8A fictional QC record completed with a rejection decision
  9. 9Recover missing links without creating replacement history
  10. 10Questions that test whether the record system is usable
AI · Explain it for MY operation

How does PET Laboratory Record apply to your shop floor?

Pick your industry and scale — Ask V5 rewrites the definition in your context, gives a worked example, and shows what V5 does on day one.

Your scale

01What a PET Laboratory Record documents

PET Laboratory Record is the documented evidence of testing performed in connection with producing a PET drug, showing what was tested, how the result was obtained, and how it compared with established acceptance criteria.

For US PET drug laboratories, 21 CFR 212.60(g) requires complete records of tests performed in connection with production. This requirement sits within the broader US PET drug CGMP framework; it is not a general laboratory-record rule for every product or jurisdiction.

PET QC test record and PET drug laboratory documentation are used here as alternative names for this documentation, not separate record classes. The focus is the evidence retained and its connections—not isotope selection, dose calculations, analytical procedures, or decay correction.

FDA's non-binding PET guidance recommendations are distinguished here from binding regulatory requirements. The proposed record architecture and fictional case illustrate practical documentation choices; they do not prescribe a mandatory form, naming convention, or system design. Their purpose is to make the relationship between test evidence and recorded decisions understandable.

02Laboratory evidence and its neighbouring records

In a PET record system, laboratory evidence, investigation findings, product disposition and distribution history answer different questions.

RecordQuestion it answersBoundary
Laboratory test evidenceWhat supports this test result?Establishes the evidential basis for the reported result; does not itself express batch disposition.
InvestigationHow is the discrepancy explained and assessed?Out-of-specification investigations connect the discrepancy to an assessment without replacing the test evidence.
Batch-release decisionWhat product disposition was recorded?Batch release records the disposition decision using supporting evidence, rather than serving as the analytical record.
Distribution recordWhere did the product go, and who received it?PET distribution records document movement and recipients rather than the basis of a laboratory result.

A production metric such as radiochemical yield serves another purpose: describing production performance. It is not a substitute for the evidence supporting a laboratory result, and yield alone does not establish product acceptance.

Linked records can form a coherent record set without being collapsed into a single document. A useful design lets a reviewer follow each conclusion back to its supporting evidence while keeping each record’s purpose clear. Document layout alone does not determine regulatory status; these functional boundaries concern how evidence is organised and understood.

03The test-record content specified in 212.60(g)

The following quotations state requirements for US PET drug laboratories. The accompanying explanations describe their evidential purpose; suggested ways of connecting records are implementation practices, not additional regulatory wording.

For US PET drug laboratories, 21 CFR 212.60(g)(1) states: "(1) A suitable identification of the sample received for testing."

Identification gives the evidence a subject. In practical record design, the reader should be able to distinguish this sample from another sample of the same product without relying on someone’s memory of what arrived at the laboratory.

For US PET drug laboratories, 21 CFR 212.60(g)(2) states: "(2) A description of each method used in the testing of the sample, a record of all calculations performed in connection with each test, and a statement of the weight or measurement of the sample used for each test."

A method name alone can leave execution ambiguous when different revisions share that name. A controlled method-version reference is a practical way to identify the applicable instructions, not an additional phrase in the regulation. Calculations connect observations to the reported result; the sample quantity helps explain the basis on which that result was derived.

For US PET drug laboratories, 21 CFR 212.60(g)(3) states: "(3) A complete record of all data obtained in the course of each test, including the date and time the test was conducted, and all graphs, charts, and spectra from laboratory instrumentation, properly identified to show the specific component, in-process material, or drug product for each lot tested."

Instrument evidence supports interpretation only when its relationship to the tested material is unambiguous. A file stored beside a worksheet may still leave that relationship uncertain. An explicit record reference is a practical way to preserve the connection when files are exported, printed, or reviewed separately. The date and time place the evidence within the test event.

For US PET drug laboratories, 21 CFR 212.60(g)(4) states: "(4) A statement of the results of tests and how the results compare with established acceptance criteria."

An isolated result reports an observation but does not explain its acceptability. In an interpretable record, the comparison lets a reader understand the assessment against the applicable criterion rather than infer it from familiarity with the product. A practical design keeps that comparison connected to the result it evaluates.

For US PET drug laboratories, 21 CFR 212.60(g)(5) states: "(5) The initials or signature of the person performing the test and the date on which the test was performed."

This attribution identifies the performer and dates the work. In practical record design, initials remain interpretable when the laboratory can associate them with the person, including during later review.

For test-specific terminology, see radiochemical purity and radionuclidic identity. These terminology links do not establish a mandatory test panel, analytical method, or acceptance limit.

04Build the record around the test event

A practical record design follows the work as information becomes available. At sample receipt, establish the connection to the material being tested. Before execution, identify the method to be used rather than reconstructing that choice from the eventual result. During execution, capture observations and instrument evidence in the context of that particular test, so later assessment does not depend on someone remembering which output belongs where.

For US PET drug facilities, FDA PET guidance, IX.B. Laboratory Controls recommends documenting laboratory controls at the time of performance. This is guidance, not a separate binding requirement. In practical record design, recording information as the work proceeds reduces reliance on retrospective reconstruction.

The illustrative data model centres on the test execution: a sample can have multiple executions, and each execution can have multiple evidence objects and record events. The batch disposition references the assessed evidence set. These relationships describe a way to organise records, not a prescribed form. They allow a reviewer to distinguish separate analytical activities without treating every attachment or later entry as another test.

Once results are available, comparison with the applicable acceptance criteria establishes the recorded assessment. An exception can then be assessed in context before the evidence set is linked to the disposition. Keeping those connections explicit helps explain what information supported the decision at the time it was made.

For interpreting chronology, distinguish when the test was executed from when a later transcription, correction, or review was recorded. A later entry does not move the test itself to that later time. This is a practical chronology convention, not an additional timestamp requirement attributed to the regulation.

A stable identifier can connect a paper entry, an instrument output, and an electronic record without depending on a particular platform or file format. The identifier provides continuity across those locations; broader record-quality interpretation belongs with the ALCOA+ principles.

Linked laboratory record objects

Sample

Identifies the material received for testing.

  • sampleId
  • batchId
  • materialIdentity

Test execution

Connects the sample to performed work.

  • testId
  • sampleId
  • methodVersion
  • sampleMeasurement
  • measurementUnit
  • calculations
  • testDate
  • testTime
  • testerInitials

Test evidence

Connects outputs with their interpreted comparison.

  • evidenceId
  • testId
  • instrumentOutputs
  • result
  • acceptanceCriteria
  • comparison

Record event

Preserves correction and investigation relationships.

  • eventType
  • originalTestId
  • priorEntry
  • correctedEntry
  • reason
  • recordedAt
  • actorInitials
  • investigationId
  • subsequentTestId

Batch disposition

Records the authorized assessment and decision.

  • batchId
  • evidenceReferences
  • decision
  • decisionReason
  • decisionBy
  • decisionAt
Illustrative entities preserve relationships without prescribing a form, database, or software platform.

05Correct a transcription without rewriting the test

A transcription correction reconciles an entered value or interpretation with its supporting evidence. It is not a replacement test or permission to alter the original analytical outcome. The basis is a demonstrable mismatch between the entry and the evidence, not a preference for a different result.

An illustrative traceability practice is to retain the earlier entry, identify the corrected entry, explain the reason, and record the correcting person’s initials and correction date. Link the correction to the supporting evidence closely enough that a reviewer can understand why the change is justified without relying on someone’s memory.

For US PET drug laboratory test records, 21 CFR 212.60(g)(5) requires the test performer’s initials or signature and the date the test was performed. Keep that attribution distinct from attribution of a later correction. The correction model described here is illustrative practice, not a quotation of that provision or an assertion that it independently specifies every correction field.

Silent overwriting obscures what a reviewer or decision-maker previously saw. On paper, a correction can preserve the legibility of the earlier entry and associate the explanation with it. In an electronic record, retained history can connect the earlier and corrected entries. The mechanism may differ; the traceability objective does not. Use the wider audit-trail review process to examine recorded changes in context.

If the entry already influenced another decision, assess that decision’s evidential basis. Document whether the corrected information changes the conclusion and what follow-up is appropriate. Calling an error a transcription error does not establish that its downstream effect was harmless.

06Keep the failed test, investigation, and subsequent test connected

For US PET drug facilities, FDA PET guidance, IX.B. Laboratory Controls recommends investigating and documenting out-of-specification results. For those same facilities, that guidance also recommends documenting and justifying deviations from written procedures. These are non-binding guidance recommendations, not a universal retesting procedure.

As illustrative record-design practice, keep the observed result separate from its investigation status. A result outside its acceptance criterion remains an observation even while its cause is unresolved. The investigation records what is being examined; its conclusion records what the evidence supports. Describing a suspected laboratory error as confirmed before the supporting findings exist obscures that distinction.

Use explicit record references to connect the original test execution, the investigation, any authorized subsequent execution, and the conclusion. Record why the subsequent test was undertaken and reference its authorization under the applicable procedure. Treat it as another evidence event with its own result, not as an unexplained revision to the original value. This lets a reviewer distinguish a new execution from a corrected entry without reconstructing the sequence from filenames or memory.

Preserve the original test evidence alongside the investigation's hypotheses, findings, and conclusion. Identify which observations support or contradict each explanation, and distinguish unresolved questions from established findings. The concluding assessment should address all available results and explain how each was treated. A later passing result should not silently replace the earlier failure or become the sole visible result merely because it is more favourable.

Keep retest authorization rules, sampling plans, analytical validation, and general investigation decision trees in their governing procedures; the laboratory record references those decisions rather than creating its own allowance to repeat testing. See out-of-specification investigation for the broader exception-handling context. The record-design goal here is narrower: a reader can follow what happened, why additional evidence was generated, and how the conclusion accounts for the complete sequence. Linking the records supports that review; it does not itself establish that a retest was justified.

07Separate test assessment from the batch release decision

Recording, checking, or approving an individual laboratory result is not the same decision as disposition of the PET drug batch. In practical record design, test assessment answers whether particular analytical evidence supports acceptance; batch disposition records the decision about the product. These meanings can remain distinct within one record and without assuming different people perform them. The broader batch release record should make the disposition identifiable rather than leave readers to infer it from approved test entries.

For US PET drugs, FDA PET guidance, D. Accepting and Releasing a Batch (Lot) describes final release for human administration under 21 CFR 212.70(c)–(d) in terms of determining that the product meets specifications, except for sterility. For US PET drugs, that guidance recommends that the designated individual review all laboratory testing and batch-record documentation to determine whether the product has met all acceptance criteria. This is a batch-level assessment, not simply confirmation that a laboratory entry has been checked.

The binding final-release step is separate from tester attribution. For US PET drugs, 21 CFR 212.70(d)(3) requires procedures ensuring a batch is not given final release until “A designated qualified individual authorizes final release by dated signature.” A tester’s initials or signature under 21 CFR 212.60(g)(5) attribute a test; the dated release signature authorizes the batch. The same qualified person may hold both roles where the facility’s organization allows it, as the staffing discussion below explains.

Conditional final release has a bounded purpose

For US PET drugs, 21 CFR 212.70(f)(1) permits conditional final release when an analytical-equipment malfunction prevents completion of a required finished-product test, subject to the provision’s conditions. A failed test and an ordinary workflow delay are different circumstances; neither should be relabelled as equipment-related inability to complete testing. For US PET drugs, check the current text of 21 CFR 212.70(f) for all applicable conditions. The documentation elements below are not a complete eligibility test.

For US PET drugs conditionally released under 21 CFR 212.70(f)(1)(v), an out-of-specification result from reserve-sample testing triggers immediate notification of the receiving facility. For US PET drugs, 21 CFR 212.70(f)(1)(vi) requires documentation of all conditional-final-release actions, including the release justification, followup actions, completed testing results, notifications, and corrective actions to prevent recurrence of the analytical-equipment malfunction.

Decision separation is not a staffing rule

For US PET drug facilities, FDA PET guidance, B. Organization and Staffing discusses designating one highly qualified individual to perform both production and quality assurance functions. Distinct decision meanings therefore should not be presented as a universal second-signature requirement. As illustrative practice, record labels can distinguish a test assessment from the disposition and connect each decision to its supporting evidence. The wider 21 CFR 212 context remains the regulatory framework.

From sample to recorded disposition
  1. 1
    Identify sampleConnect received material to its batch and intended testing.
  2. 2
    Establish method contextAssociate the applicable method and criteria with execution.
  3. 3
    Capture executionConnect performer, timing, measurements, calculations, and instrument evidence.
  4. 4
    Record comparisonDocument the result against the applicable acceptance criteria.
  5. 5
    Resolve record exceptionsExplain corrections while retaining earlier entries and supporting evidence.
  6. 6
    Assess analytical exceptionsConnect failures, investigations, subsequent tests, and documented conclusions.
  7. 7
    Record dispositionAn authorized person documents the separate batch decision.
Illustrative record progression; product-specific procedures govern execution and authorized decisions.

08A fictional QC record completed with a rejection decision

This illustrative US PET drug case concerns BATCH-ALDER, tested using established product-specific methods and acceptance criteria. TEST-ALDER and TEST-BIRCH are neutral record labels, not a proposed PET test panel. The linked execution records are assumed to contain the applicable sample measurements and units, calculations, method versions, and actual execution dates and times. The narrative uses qualitative acceptance comparisons and relative event order; it introduces no analytical values, numerical limits, or calculation methods. Record references below are fictional identifiers.

Episode A: correct the comparison entry

Analyst JT completes TEST-ALDER and attaches its original instrument output as OUTPUT-ALDER. That output supports a conforming comparison with the applicable established criterion. When entering the comparison into the laboratory record, however, JT transcribes it as nonconforming. The execution retains JT’s tester attribution and test date, together with the underlying evidence reference. The mistaken comparison is an entry in that record, not a different instrument result.

JT reconciles the entry against OUTPUT-ALDER and records CORRECTION-ALDER. The correction preserves the erroneous entry, identifies the corrected comparison as conforming, and states that a transcription mistake caused the discrepancy. JT adds initials and the correction’s recorded date. The correction refers directly to the affected entry and OUTPUT-ALDER, so a reviewer can distinguish the original test date from the later correction date. Neither the analytical evidence nor the calculation is changed. CORRECTION-ALDER is complete; it does not serve as the investigation of the separate failure that follows.

Episode B: retain the failure and its follow-up

Analyst KD completes TEST-BIRCH. Its original evidence, OUTPUT-BIRCH, supports a failing comparison against the applicable established criterion. KD’s initials, test date, execution time, evidence reference, and failing comparison remain attached to this execution. Unlike the TEST-ALDER entry, this comparison agrees with the original output. The batch record links the failure to INVESTIGATION-BIRCH for the site’s out-of-specification review.

INVESTIGATION-BIRCH preserves OUTPUT-BIRCH and documents the review of sample identification, the recorded method version, execution entries, calculations, and the acceptance comparison. REVIEW-BIRCH identifies the records examined and the findings. The investigation establishes no supported basis for invalidating the original failure. Its record does not assign an unsupported analytical cause merely to close the review.

An authorized subsequent test is documented as the separate execution TEST-BIRCH-FOLLOWUP, with its authorization, tester attribution, execution details, and OUTPUT-BIRCH-FOLLOWUP retained. It links back to both TEST-BIRCH and INVESTIGATION-BIRCH and also fails its applicable criterion. The recorded investigation conclusion cites OUTPUT-BIRCH, REVIEW-BIRCH, and OUTPUT-BIRCH-FOLLOWUP: the original failure remains supported, and the subsequent execution also shows nonconformance. Both comparisons remain visible. The follow-up neither substitutes for the original result nor creates a release authorization.

Episode C: record the completed batch decision

MR, the site’s authorized batch decision-maker in this hypothetical case, assesses the completed evidence set in RELEASE-ASSESSMENT-ALDER. This separate batch release assessment is associated with the US PET drug specifications-and-release framework in 21 CFR 212.70. MR records attribution, the decision date, and the disposition: BATCH-ALDER is rejected; final release for human administration is not authorized.

The recorded reason is the supported TEST-BIRCH failure, with no established basis for invalidation and a further failing comparison in TEST-BIRCH-FOLLOWUP. MR cites those executions, INVESTIGATION-BIRCH and its evidence references, and the completed TEST-ALDER correction. The case closes with the correction complete, the investigation conclusion recorded, the subsequent execution linked, and the batch disposition recorded—not an unresolved hold. The conditional-final-release route discussed above is not used.

09Recover missing links without creating replacement history

Handoffs between instrument output, laboratory documentation, investigations, and batch assessment can leave records disconnected even when the underlying test evidence remains intact. A practical recovery approach starts by identifying the failure, then assessing whether it affects analytical interpretation, record completeness, or both:

  • Mismatched sample identifiers: reconcile the identifiers against authoritative sample and test records before associating the output with a batch; a plausible filename alone is insufficient.
  • Duplicate imports: establish whether the entries represent the same test event or separate tests before marking an entry as a duplicate.
  • Missing attachment: locate the original output and confirm its association with the test; assess whether its absence prevents interpretation of the recorded result.
  • Interrupted transfer: compare the source record with the received content to establish what arrived, what remains missing, and whether a retry created duplicates.

Recover from the authoritative evidence rather than reconstructing expected content. Document what was recovered, its source, who performed the recovery, and when. Preserve the link between the original event and the later recovery action, including affected investigation or batch-assessment references. As covered above, successful re-import time is not original test time.

Use data integrity principles to assess the recovered evidence. Govern changes to mappings, interfaces, or record templates through change control, rather than silently adjusting them during recovery. A successful transfer alone does not establish compliance.

10Questions that test whether the record system is usable

Use these practical readiness questions to challenge the PET laboratory record system, not to add legal requirements. Try them against an archived record with someone who did not perform the work.

  • Can a trained replacement reviewer reconstruct the evidence without relying on the original analyst’s memory or informal explanations?
  • Will archived references remain intelligible when a method repository, instrument workstation, or file location changes?
  • Who resolves conflicting identifiers when the laboratory record and batch execution history appear to describe different samples?
  • Does the escalation path identify an owner when evidence is readable but its meaning cannot be established?
  • Can the team demonstrate that a recovered attachment belongs to the historical execution, rather than merely having a plausible filename?
  • What event closes a record-handling exception, and where is that closure connected to any decision it affected, including the electronic release record?

Treat unanswered questions as practical improvement opportunities with named owners and observable completion evidence.

Frequently asked questions

Q.How should an outsourced laboratory's report connect to the PET producer's laboratory record?+

As a record-design practice, connect the contractor’s report to the producer’s batch and sample identifiers, including any identifier assigned during laboratory receipt. Preserve the report’s revision status and identify the supporting analytical records and their retrieval location. Document who reconciled the received report with the requested testing and resolved discrepancies. A sample login and handoff record can provide that connection without copying the contractor’s entire report into another form. Keep report receipt distinct from the producer’s disposition decision.

Q.Is a summary PDF enough when the instrument also generated graphs or spectra?+

Treat a summary PDF as a review aid rather than assume it represents the entire analytical record. As a practical completeness check, determine whether it preserves the generated graphs or spectra, their sample association, and the context needed to interpret the reported result. If relevant information remains elsewhere, retain an explicit, retrievable connection to it. The distinction between dynamic and static records helps assess whether exporting to PDF removed information needed to reconstruct or evaluate the analysis.

Q.How should a recalculated result be distinguished from a corrected transcription?+

Use separate change descriptions as a documentation practice. A transcription correction fixes a copied entry to match its source; a recalculation produces a revised result from identified inputs and calculation rules. For either event, preserve the earlier entry and record the reason, date, and responsible person’s initials or signature. For recalculation, also retain the inputs, calculation version, revised output, and assessment of its effect on the result’s interpretation. A recalculation record can organize that additional context.

Q.Which acceptance-criteria version belongs with a result when a specification changes during review?+

For US PET drugs, 21 CFR 212.60(g)(4) requires a statement of test results and their comparison with established acceptance criteria. As a version-control practice, preserve the criteria used for the original comparison and document the applicability decision for the changed specification. If reassessment is appropriate, add a separately identified comparison rather than silently replacing the earlier one. Link the effective-date rationale and approval to the relevant specification change history, so reviewers can reconstruct both evaluations.

Q.How should an aborted analytical run be represented when no reportable result was produced?+

As a record-design practice, represent the aborted run as an analytical event, not as a passing result or an unexplained gap. Associate it with the sample, instrument, operator, available timestamps, and any data generated before termination. Record the observed reason for stopping, distinguishing an established cause from an unresolved observation. Identify any subsequent run separately and explain its relationship to the interruption. The process event log can provide context, but should not replace the analytical event’s supporting records.

Q.Can an early distribution notice be treated as permission for human administration?+

No. For US PET drugs, FDA’s non-binding PET Drugs CGMP guidance, D. Accepting and Releasing a Batch (Lot) describes release for distribution, but not administration, while some tests are pending, and qualifies that “Other than sterility testing, all finished-product tests would have to be completed or in progress at the time of shipment or distribution.” Pending therefore does not mean not yet started. As a communication practice, label the notice with its actual purpose and avoid wording that implies administration authorization. Keep the receiving facility’s acknowledgment and any later release communication distinguishable in the PET distribution record. Shipment status alone is not a sound basis for interpreting a release message.

Q.How can a team show that record migration preserved the meaning of historical results?+

Use a documented migration assessment that tests interpretation, not merely file counts. As a practical approach, compare source and destination records for sample relationships, units, calculation context, criteria versions, timestamps, attribution, and links to corrections or investigations. Include records with exceptions and amendments, because these expose relationships that simple exports can flatten. Record discrepancies and their resolution, and retain the migration mapping. A requirements traceability record can connect each preservation objective to its test and recorded conclusion.

Q.How should a laboratory attachment received after batch disposition be added and assessed?+

Add it as a dated, attributable supplement rather than inserting it as though it had been available during the original decision. As a documentation practice, record when it arrived, what it concerns, and why it was received late. Identify whether it adds information, corrects an earlier report, or changes interpretation. Route that assessment to the responsible reviewer and document the conclusion and any resulting action. Preserve the original batch disposition record alongside the later assessment so their chronology remains clear.

Primary sources

  • 21 CFR 212.60 Laboratory controls
  • 21 CFR 212.70 Specifications and release
  • FDA PET Drugs CGMP guidance (Dec 2009)
Software that covers PET Laboratory Record
V5 Ultimate Radiopharmaceutical Manufacturing
Time-stamped batch record for short production windows, QC results tracked as available or pending, human release review and Part…
V5 Ultimate LIMS
V5 includes laboratory information management alongside production and quality: sample plans, requests, lab queues and results…
Talk to us about PET Laboratory Record

Want to see how PET Laboratory Record could fit into your own records and workflows? Explore the related V5 pages or talk to our team about what applies to your operation.

Start free
Back to glossary
Where this term comes up
Radiopharma
Related terms
  • → 21 CFR 212
  • → PET Distribution Record
  • → Radiochemical Purity
  • → OOS

Next Step

Try V5 with your own records, or ask a question first. Ask V5 opens with an editable question; nothing is sent until you choose to.

Start your free trial Browse All Features

Showing the site for the United States. Local spelling, dates and prices are applied automatically; change the language at the top of the page.

V5 Ultimate
Ultimate

Warehouse, quality and manufacturing software for regulated operations.

ProductIndustriesPricingResourcesSecurity & TrustCompanyLegal Centre

© S.G. Systems, LLC